Plan Number: S19-057
Parcel: Unknown

Address:
3300 S PARK AV

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S19-057
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/16/2019 SBEASLE1 START PLANS SUBMITTED Completed
08/16/2019 SBEASLE1 UTILITIES SOUTHWEST GAS Passed Review not required. This agency was notified for their information only.
08/16/2019 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed Review not required. This agency was notified for their information only.
08/16/2019 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed Review not required. This agency was notified for their information only.
08/19/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved This was already requested by Samantha Thompson at Cypress back in May of 2019. Parcel 132130750 and letter was processed & sent to her.

Kellie Anderson, Administrative Assistant
Tucson Water-New Development
Ph: (520) 837-2165
08/19/2019 ED ABRIGO PIMA COUNTY ASSESSOR Approved FROM: Julieann Arechederra,GIS Cartographer
Pima County Assessor's Office
DATE: August 16, 2019
RE: Assessor's Review and Comments Regarding:
BRIDGES THE, LOTS 1-8 FINAL PLAT S19-057

X Plat meets Assessor's Office requirements.
08/21/2019 JIM EGAN COT NON-DSD FIRE Completed
09/04/2019 PCAMARE1 ZONING HC REVIEW Reqs Change See Zoning Comments
09/04/2019 PAUL CAMARENA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: Final Plat for The Bridges SUB-Area B-IV Lots 1 through 8 and Common areas "A" and "B"
Final Plat (1st Review)
S19-057

TRANSMITTAL DATE: September 3, 2019

DUE DATE: September 16, 2019

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013)


2-07.3.0 SUBMITTAL TIMING
Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.

2-07.4.0 FORMAT REQUIREMENTS
Plats must:
4.1 Be on a 24-inch by 36-inch sheet(s) folded to the eight and one-half inch by 11-inch format shown in Exhibit I. The plat may comprise several sheets showing various elements of required data;
4.2 Be prepared on materials that can be transferred to double-matt Mylar reverse read;
4.3 Have a two-inch margin on the left side and one-half inch margins on the remaining sides to comply with standardization requirements of state law for recorded plats;
4.4 Be drawn to a scale of no more than one inch equals 40 feet; and,
4.5 All lettering and dimensions shall be three-thirty-seconds inch in height.

2-07.5.0 CONTENT REQUIREMENTS


2-07.5.1.C If the project is located within the boundaries of a Planned Area Development (PAD) zone, include a reduced-scale map of the entire PAD on the first sheet, indicating the location of the portion being developed.

1. COMMENT: Revise the PAD location map to encompass the entire PAD area.



2-07.5.1.H - The Subdivision Case number assigned to the final plat and the DP case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

2. COMMENT: Provide the subdivision case number, S19-057 in the right hand corner of the plat next to the title block.



2-07.5.2.B "The total number of lots is ____."

3. COMMENT: Revise the total number of lots to 8 and include the two common areas



2-07.5.4.K. If the plat represents one phase of a multiphased project and access is provided through this phase to the future phases, indicate the access easements or public streets on this plat that will guarantee the access; and,

4. COMMENT: Clarify if lots 1,2,6,7,8 will have access from Park Ave or will there be a ingress egress easement that provide access.


2-07.5.6 Protective Covenants

Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will:
2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and

5. COMMENT: Will separate CC&R's be recorded for this Plat or are there master CC&R'S for the overall PAD


If you have any questions about this transmittal, Contact Paul Camarena at (520) 791-5550 or by email Paul.Camarena@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
09/05/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change September 5, 2019
ACTIVITY NUMBER: S19-057
PROJECT NAME: Final Plat for the Bridges Lots 1 - 8
PROJECT ADDRESS: Bridges Sub-Area B-IV
PROJECT REVIEWER: Zelin Canchola TDOT

Resubmittal Required: The following items must be revised and added to Final Plat

1. The design of the Bridges must encourage internal connections and cross access, not only by motorized vehicles but by pedestrians and bicyclist. Provide a no access easement along Park Ave and show cross access easements interior to the property to the lots fronting Park Avenue. Transportation will not support multiple access points from park Ave.


If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
09/09/2019 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Completed
09/10/2019 KAY MARKS PIMA COUNTY ADDRESSING Reqs Change (The "attached PDF" mentioned here can be viewed on PRO in the "Documents" section)

S19-057 / Bridges, final plat / 1st submittal is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments.
Please let me know if you have any questions.
Thank you,
Robin Freiman, Addressing Official
Pima County Development Services Department
201 N Stone AV – 4th Floor Tucson, AZ 85701
(520) 724-7570
09/11/2019 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed Please submit the DRC self-certification letter with the development package.
Thank you.
John Beall
John.Beall@TucsonAz.gov, (520) 791-5550, office
09/12/2019 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved Tucson Parks and Recreation has no issues or concerns regarding approval of this plat.
Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation, (520) 837-8040
Howard.Dutt@tucsonaz.gov
09/16/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS

2-07.3.0 SUBMITTAL TIMING

Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.

Landscape section cannot approve Final Plat until Tentative Plat is approved.

Ensure that all Zoning comments are addressed.
09/16/2019 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the final plat submitted on August 16, 2019.
Please call the New Construction Department at 520-918-8300 to apply for service. Submit a final set of approved plans including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required, they will be obtained by separate instrument.

Please contact me at 520-917-8744 should you have any questions.
Thank you,
Mary Burke, Senior Right of Way Agent
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road, Tucson, AZ 85714-2114
Office - 520-917-8744, Cell - 520-401-9895, mburke@tep.com
09/17/2019 LOREN MAKUS ENGINEERING REVIEW Approved
09/18/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: S19-057
Description: FINAL PLAT/BLOCK PLAT - Bridges Sub-Area B-4, Block 10, Lots 1-8 and common areas "A" (private street and utilities) and "B" (drainage).
Fees Due: $ 5,922.19
Note: Prior to accepting a resubmittal, we require payment
Please pay the total fees (or Review Fees at a minimum):
1. Online
2. In person at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to City of Tucson, address is shown below, include the Activity Number

City of Tucson - Online Payments:
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. Total fees due: Payment portal may take 1-2 days to update to the correct total
2. Not case-sensitive but a hyphen is needed, e.g.: dp19-0000
3. Enter your Permit Nbr. and click the “Continue” tab
4. If any issues, try using the browser Internet Explorer.
5. Accepted: Visa, MC, Discover, or American Express
6. All data and transactions are securely encrypted

To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data uploads to PRO periodically.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
09/18/2019 SBEASLE1 PIMA COUNTY WASTEWATER Reqs Change Applicant is responsible for obtaining review and approval for wastewater from Pima County at email Sewer@pima.gov prior to Mayor & Council approval of the final plat. Provide approval in resubmittal.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/18/2019 SBEASLE1 OUT TO CUSTOMER Completed