Plan Number: S19-051
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S19-051
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/23/2019 SBEASLE1 START PLANS SUBMITTED Completed
07/25/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
07/29/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Clarify the lot boundaries.
2. Show how the current buildings are connected to the public sewer. If they are all connected to a common sewer connection, provide a joint sewer use agreement. If the lots are to have independent sewer connections, show how lot 2 will be able to install an independent connection to the public sewer.
3. Three water meters serve the present lot but after the lot split, the meter serving lot 1 will be remotely located. For the purposes of having a water meter, a parcel is required to have a minimum width of 15-feet of frontage on a water main. An easement is not considered to be frontage. Reference: Tucson Water Remote Meter Policy, Number IV-B.08, dated 07/14/2009.
07/29/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Tucson Water approves of lot split.
Thanks,
Ray Munoz
Ray.Munoz@Tucsonaz.gov
07/29/2019 LOREN MAKUS ENGINEERING REVIEW Denied CREATION OF THREE LOTS FROM A SINGLE SUBDIVIDED LOT REQUIRES A SUBDIVISION PLAT.
07/30/2019 SSHIELD1 H/C SITE REVIEW Passed
07/30/2019 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: 2433 E Cameron Vista - R-2 zone
S19-051
Land Split (1st Review)

TRANSMITTAL DATE: July 30, 2019

1. The land split plans and documents have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. As this parcel SUNLAND GARDENS AMENDED LOT 96 was created via a plat it only qualifies for a single split creating a total of two (2) parcels, see UDC Article 11.4.3 Definition of Land Split, Lot split has the same meaning as "land split" as defined in A.R.S. ยง9-463(3), that is, the division of improved or unimproved land for the purpose of sale or lease, which is not defined as a subdivision, whose area is two and one-half acres or less in size, into two tracts or parcels if previously platted. To create three parcels out of this parcel a minor subdivision would be required.

3. Per UDC Table 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-2 zoning allows for 15 units per acre. Based on 15 units per acre a duplex parcel requires 5,808 sq. ft. minimum. That said Lot 2 does not meet the minimum size.

4. Based on current aerial photos of this site there is some type of connection, patio between the guest house and the duplex and there is an accessory structure located on the proposed lot 3. These structures will need to be removed prior to completing the minor subdivision process.

5. This land split review cannot be approved.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
07/30/2019 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.

Permit/Activity Number: S19-051
Description: LAND SPLIT - Cameron Vista.
Fee Balance: $0 (zero). Thank you for the payment.
For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (states how all reviewer comments were addressed)
2) Any other items requested by reviewers

After resubmittal, the Plan will enter a new 5-working-day Land Split review cycle.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
07/30/2019 SBEASLE1 OUT TO CUSTOMER Completed