Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S19-046
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/17/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 07/24/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Zoning Review Section PROJECT: 2200 S HOUGHTON RD Land Split (1st Review) S19-046 TRANSMITTAL DATE: July 23, 2019 DUE DATE: July 24, 2019 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 8.3.1. LAND SPLIT A. Purpose According to A.R.S. ยง9-463.01(T), the City may regulate a land split as defined in Section 11.4.13 within its jurisdictional limits. The state law gives the City authority to determine the division lines, area, and shapes of the parcels. Neither a tentative plat nor a final plat is required but the resulting tracts or parcels shall conform to applicable zoning requirements and other government codes and ordinances. The purpose of this section is to establish a review process for land splits. This review: 2-08.5.0 CONTENT REQUIREMENTS The drawing showing the proposed land split shall include the following: 2-08.5.0 A. The boundaries of the original parcel or lot prior to the land split with distance and bearings labeled; 1.Comment: Zoning has reviewed Lot Split and Legal Description unfortunately we will not be able to approve, please address the following comments below. 2-08.5.0 B. The proposed lots with distance and bearings labeled; 1.Comment: The survey drawing does not include a drawing that matches the legal descriptions. Parcel B on the South East corner on Houghton Road and the North section on Old Spanish Trail requires a solid line that need to match legal description. 2-08.5.0 G. The land area of each proposed lot in square feet or acreage. If the property is developed, additional information, such as but not limited to FAR, lot coverage, vehicle and bicycle parking, may be needed; 1.Comment: Provide area of each proposed lot in square feet or acreage. 1.Comment: Provide a Title block that includes the name of the Land Division and the parcel numbers. If you have any questions about this transmittal, Contact Paul Camarena at (520) 791-5550 or by email Paul.Camarena@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 07/25/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | The metes and bounds of the legal description don't match the survey drawing. Please submit consistent documentation for the lot split. |
| 07/26/2019 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE The reviews have been completed and a resubmittal is required. Fee Balance: $0 (zero). Permit/Activity Number: S19-046 Description: LAND SPLIT - Northwest Medical Center, Houghton. For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (states how all reviewer comments were addressed) 2) Any other items requested by reviewers After resubmittal, the Plan will enter a new 5-working-day Land Split review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/26/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |