Plan Number: S19-040
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S19-040
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2019 SBEASLE1 START PLANS SUBMITTED Completed
06/18/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
06/18/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/19/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Tucson Water approves of this lot split.
Thank you,
Ray Munoz
06/19/2019 LOREN MAKUS ENGINEERING REVIEW Approved
06/20/2019 DAVID RIVERA H/C SITE REVIEW Approved
06/20/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Sunset Ranch - Parcels "A" and "B"
Land Split (1st Review)
S19-040

TRANSMITTAL DATE: June 20, 2019

DUE DATE: June 21, 2019

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

8.3.1. LAND SPLIT

A. Purpose
According to A.R.S. ยง9-463.01(T), the City may regulate a land split as defined in Section 11.4.13 within its jurisdictional limits. The state law gives the City authority to determine the division lines, area, and shapes of the parcels. Neither a tentative plat nor a final plat is required but the resulting tracts or parcels shall conform to applicable zoning requirements and other government codes and ordinances. The purpose of this section is to establish a review process for land splits. This review:

Please address the following zoning comments and resubmit for review.

1. Comment: List the assigned Land Split case number S19-040 next to the title block of all plan sheets.
List as reference the DP case number DP16-0206.


2. Comment : Originally when the DP was approved a determination was made to allow the development to move forward with a greater than 3 Acre max parcel for the personal storage use. However that determination was made based on the proposal at the time.

Per UDC Use Specific Standards,

C. Personal Storage
1. All storage shall be within enclosed buildings.
2. Access shall be from a collector or arterial street.
3. All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non- reflective material.
4. The maximum permitted individual unit size is 200 square feet of floor area.
5. Razor or barbed wire shall not be used.
6. The facility's exterior facade visible from adjoining residential properties or street frontage shall be earth tone in color and of masonry, stucco, or similar materials.
7. The maximum permitted site area is three acres.

The maximum allowed acreage for a personal storage use in the C-1 zone is 3 acres. Per the survey, Parcel "A" which is the parcel for the Personal Storage use is listed as 3.22 acres. Zoning cannot approve the land split as proposed. Technically the site would have to be rezoned to C-2.

A consultation with the Zoning Administrator would be in order for any additional options with regard to the Maximum 3 Acre UDC 4.9.10.C.7 standard.

3. Comment: Revise the legal descriptions and survey drawing accordingly.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Land Split Survey and Legal Descriptions
06/20/2019 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE

The reviews have been completed and a resubmittal is required.

Fee Balance: $99.00 (see the Balance column in the image below).

Prior to the completion of the next review, we require payment of the total fees (or the Review fees at a minimum). You may pay in person at the City of Tucson permit counter or mail a check payable to the City of Tucson (see address below). Please write your Activity Number on the check stub.

Activity Number: S19-040
Project Description: LAND SPLIT - Sunset Ranch.

For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.

(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)

After all corrections are made, please name your 2nd submittal documents accordingly, for example: 2_Lot_Split_Exhibit.

Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.

In the Project Description field, please include the Activity Number.

1) Comment Response Letter (lists changes made and which reviewer comments you are responding to)

2) Any other items requested by review staff

After resubmittal, the plas will re-enter the Land Split 5-working-day review cycle.

Thank you.

Sharon Beasley, Permit Technician

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
06/20/2019 SBEASLE1 OUT TO CUSTOMER Completed