Plan Number: S19-023
Parcel: Unknown

Address:
8525 E 22ND ST

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S19-023
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2019 SBEASLE1 START PLANS SUBMITTED Completed
04/15/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved See Water Availability Letter in SIRE for DP18-0060, development package.
04/15/2019 SBEASLE1 UTILITIES SOUTHWEST GAS Passed No review needed. This is being sent to this agency for their information only.
05/10/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Arroyo Reserve - FLD Development - Lot 1 to 49 and Common areas "A" & "B"
Final Plat (1st Review) 8525 E. 22nd Street
S19-023 - C-1 Zoning

TRANSMITTAL DATE: May 10, 2019

DUE DATE: May 13, 2019

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013)


2-07.3.0 SUBMITTAL TIMING
Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.

2-07.5.1.E Provide a title block in the lower right corner of each sheet with the following information:

2-07.5.1.E.1 Subdivision name; number of blocks, lots, and/or units; and common area;

1. COMMENT: Assure that the information in the title block of the final plat matches the information listed in the title block of the tentative plat. (Specifically that this is an FLD Development)


2-07.5.1.H - The Subdivision Case number assigned to the final plat and the DP case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

2. COMMENT: List the subdivision case number S19-023 next to the title block of both sheets.

2-07.5.2.H Add the following note on all plats. The purpose of this note is solely for review for compliance with local and state laws governing subdivision and land splits. "There will be no further division of lots without the expressed approval of the City of Tucson."

3. COMMENT: Revise General note 8 to match what is listed in the standard above.


2-07.5.2.J If applicable, add the following note: "This subdivision is subject to Ordinance No. ____ which established zoning in the _____________________ Annexation Area."

4. COMMENT: Add the above as a general note and fill in the ordinance number with "2724" and the "Pantano" as the annexation area.


2-07.5.4.B. Identify each block or lot within the subdivision boundary by number, and include the square footage of each;

5. COMMENT: The square footage of lots 19and 20 is not legible. Assure that the SF text is legible for lots 17 through 26 and Common Area A next to lot 27.


2-07.5.4.H. Show no-vehicular access easements where applicable;

6. COMMENT: If applicable indicate on the plat the locations for any No-vehicular access easements.


2-07.5.6 Protective Covenants
Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will:
2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and

7. COMMENT: Clarify if copies of the CC&R's were provided to reviewers during the tentative plat review process. If not include a copy of the CC&R's with the next submittal of the final plat.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
05/13/2019 ALEXANDRA HINES PIMA COUNTY WASTEWATER Reqs Change Applicant is responsible for obtianing review and approval for wastewater from Pima County at sewer@pima.gov prior to Mayor & Council approval. Provide approval letter in resubmittal.
05/13/2019 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the final plat submitted on April 15, 2019. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission.
If you have any questions, please contact me at 520-917-8744.
Thank you,
Mary Burke, Senior Right of Way Agent
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744, Cell - 520-401-9895
mburke@tep.com
05/15/2019 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
240 N STONE AVENUE
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)



FROM: Janice Wagner
GIS Cartographer
Pima County Assessor's Office


DATE: April 05, 2019


RE: Assessor's Review and Comments Regarding:

ARROYO RESERVE - S19-023-1ST FINAL REVIEW



* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
___X____ Plat does not meet Assessor's Office requirements.

COMMENTS:



" THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER OF THE PLAT HAS THE INCORRECT RESUB INFORMATION. A PORTION OF DESERT STEPPES ESTATES BK 16/PG.1 WAS ALREADY RESUBDIVIED IN 2010. NOW KNOW AS BARRIOR ARROYO IN BK 64, PG.76 LOTS 1-106 & C. A. A & B.


" THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION.

" CHECK OWNERSHIP TO MAKE SURE IT MATCHES WHAT WE HAVE. OUR RECORDS STILL SHOW IN THE NAME BARRIO ARROYO LLC.




NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
05/16/2019 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Provide the correct activity number (S19-023) on each plan sheet and in all associated documents.
2. Ensure that all letters and numbers on the plat are legible and not partially or fully obscured by other letters and number or other drawing elements.
3. Revise the second paragraph in the dedication to reflect the requirements of the City of Tucson (AM 2-07.5.3.B.3)
05/16/2019 SBEASLE1 PIMA COUNTY ADDRESSING Approved The Addressing review of S19-023 Arroyo Reserve Lots 1-49 Final Plat, 1st submittal, is Approved by Pima County Addressing.
Thank you,
Robin Freiman, Addressing Official
Pima County Development Services Department
201 N Stone AV – 4th Floor
Tucson, AZ 85701
(520) 724-7570
05/29/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Approv-Cond PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Activity Number: S19-023
Project Description: FINAL PLAT - Arroyo Reserve, Lots 1-49, common areas "A" (recreation) and "B" (drainage and landscape).
To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) After all corrections are made, please name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, include the Activity Number.
1) Comment Response Letter (lists changes made to the Plan and which reviewer comments you are responding to)
2) Corrected Plan Set (all pages, full set)
3) Any other items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. Prior to the completion of the next review, we require payment of the total fees (or the Review fees at a minimum). You can either pay in person at the permit counter or mail a check payable to the City of Tucson (address is below). Include the Activity Number on your check stub.
The fee balance is $2,515.30 (see the Balance column in the image below). The Project Manager can be reached via email or phone: Andrew.Connor@TucsonAz.gov, (520) 837-4950.
Thank you.
Sharon Beasley

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
05/29/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Approv-Cond CITY DEVELOPMENT REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

May 29, 2019
Marum & Assoc Engineering
Attn: Patrick William Marum
2730 E. Broadway Blvd Suite 250
Tucson Az 85716

Subject: (S19-023) Arroyo Reserve, Lots 1-49, common areas "A" and "B" Final Plat

Dear Patrick,

The above referenced project has been CONDITIONALLY APPROVED by the City Development Review Committee. Please make any necessary corrections and submit the following documents:

1 Executed Final Plat on Double Matte Océ or Photo Mylar.

1 Title reports current within the last thirty (30) days or statement from Title Company certifying the title report previously submitted is still valid.

1 Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a flat $4.00 handling fee, along with Consent to Dedicate and CC&R fees if applicable. Consent to Dedicate and CC&R fees are $30.00 flat fee per document. If you are unsure of the fees, please call the County Recorders Office at 520-740-4350. Check must be dated within 45 days of the scheduled Mayor & Council meeting.

1 Original Set of executed and notarized CC&R (if applicable) and Assurance (if applicable).

1 Provide the property owner(s) and engineering mailing addresses on a sheet of paper in the submittal to receive proper notification 1 week prior to the Mayor & Council Meeting (if no assurances).

1 Upload a PDF scan of executed Plat, CC&R (if applicable), Assurance (if applicable), title report, and mailing address to https://www.tucsonaz.gov/file-upload-pdsd.

The Planning and Development Services Department makes sure the Assurances (if applicable) are reviewed by the City Attorney's Office prior to being presented to the Mayor & Council. Plats, CC&R's and assurances must be approved at the same Mayor & Council Meeting. Please expect 5 weeks from the date submitted to the date scheduled for Mayor & Council approval.

Should you have any questions, please call me at (520) 837-6975.

Sincerely,


Alexandra Hines
Lead Planner

All comments for this case are available on our website at www.tucsonaz.gov/PRO.

Via Permits Plus/E-mail

Final Status

Task End Date Reviewer's Name Type of Review Description
05/17/2019 SBEASLE1 OUT TO CUSTOMER Completed