Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S19-011
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/20/2019 | SBEASLE1 | START | PLANS BEING WALKED THRU | Completed | |
| 02/22/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. If parcel 1 and parcel 2 are using the same connection to the public sewer, provide a joint sewer-use agreement or indicate how a second connection will be made to the public sewer. 2. Will a second water meter be installed to serve parcel 1? |
| 02/25/2019 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 02/25/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | 02/21/19 Tucson Water has no issues with this parcel split. There will be enough frontage for both parcels to receive water. Thank you, Ray Munoz New Services, Tucson Water |
| 02/26/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: S19-011 Lot Split - 2 Lots (1st Review) 1335 E. Prince Road R-2 Zoning TRANSMITTAL DATE: February 26, 2019 DUE DATE: February 26, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: Zoning has reviewed the Lot Split documents and finds that the legal descriptions are consistent with the survey drawing. Please address the following zoning comments and re-submit for review. 02. COMMENT: Survey Drawing: List on the survey the number of dwellings to remain on each lot. Label the section corners on the location map. Revise the easement line to show as a dashed line for the north 25 foot section. Based on review of the current aerial it appears that there are portions of the access easement that do not provide for a clear 25 foot easement. Clarify if the existing vegetation is to be removed? Clarify if there will be a no vehicle access easement added to the remaining west and north property lines of parcel 2. Again per the aerial there are vehicle areas currently that are being use to access the northern dwelling on parcel 2. I may be best to extend the access easement to match the new north lot line of parcel 2. It also appears that an easement over the northwest corner of parcel 2 will be needed to grant vehicle access to the existing drive area to the 473 sf dwelling parking area. 03. COMMENT: On the individual drawings for each parcel list a density calculation listing the allowed and proposed RAC on each lot. Lot one calculation = 22,462 sf / 43,560 SF = .51 ac x 15 = 7 RAC allowed / 4 Dwelling units proposed (existing). Lot two calculation = 8788.8 sf / 43,560 SF = .20 ac x 15 = 3 RAC allowed / 2 Dwelling units proposed (existing). If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 02/26/2019 | DAVID RIVERA | H/C SITE | REVIEW | Passed | |
| 02/27/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 03/01/2019 | ALEXANDRA HINES | ZONING-RECORDATION | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE The review has been completed and a resubmittal is required. Activity Number: S19-011 Project Description: LAND SPLIT - 1335 E. Prince Road, Parcels 1 and 2 To see Zoning review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.) Prepare a Comment Response Letter detailing changes to the plan and which review comments are being addressed. After the necessary corrections have been made, submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. Enter the Activity Number in the Project Description field and name the file as directed, for example, second submittal: 2_Plan_Set.pdf. 1) Comment Response Letter 2) Corrected plan set with all documents 3) Items requested by review staff The fee balance is $0 (zero). Thank you, Alexandra Hines City of Tucson Planning and Development Services 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/08/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |