Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S19-004
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/04/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | No review needed as this involves less than six lots. |
| 06/04/2019 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | Review not required. This agency was notified for their information only. |
| 06/28/2019 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | No final plat for Mohave Stone was provided for review. Thank you, Mary Burke, Senior Right of Way Agent Tucson Electric Power Co. Land Resources β RC 131 3950 E. Irvington Road, Tucson, AZ 85714-2114 Office - 520-917-8744, Cell - 520-401-9895 mburke@tep.com |
| 07/03/2019 | ALEXANDRA HINES | PIMA COUNTY | WASTEWATER | Reqs Change | Applicant is responsible for obtaining review and approval for wastewater from Pima County at sewer@pima.gov prior to Mayor & Council approval. Provide approval is resubmittal. |
| 07/05/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Mohave Stone - Lots 1 through 3 - Minor Subdivision w/ Tentative Plat Final Plat (1st Review) - 3402 N. Stone Avenue S19-004 - TRANSMITTAL DATE: July 5 2019 DUE DATE: July 2, 2019 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013) 2-07.3.0 SUBMITTAL TIMING Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat. 2-07.5.0 CONTENT REQUIREMENTS 5.1 General 2-07.5.1.A.3 Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and, 1. COMMENT: List the recorded subdivisions within the one square mile area depicted in the location map. 2-07.5.1.D Place the words "SEQ#________" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation. 2. COMMENT: Add the "SEQ. # and underline" on sheet in the upper right corner. 2-07.5.1.E Provide a title block in the lower right corner of each sheet with the following information: 2-07.5.1.E.1 Subdivision name; number of blocks, lots, and/or units; and common area; 3. COMMENT: Rename in the title block the title of the project to "Final Plat for Mohave Stone Subdivision" of both sheets. 2-07.5.1.G Line weights will reflect the nature of the line, e.g., right-of-way lines must be more prominent than lot lines or easements and drainage ways must be shown in heavy solid lines except at street crossings. 4. COMMENT: On Sheet 2, add the dimension lines for the street right of ways. 2-07.5.1.I A legend which shows and describes all symbols used on the drawing must be placed on either the first sheet of the plat or the first sheet which contains all or part of the subdivision drawing. 5. COMMENT: Include on sheet one a legend of the symbols and line work used on sheet two. 2-07.5.2.J If applicable, add the following note: "This subdivision is subject to Ordinance No. ____ which established zoning in the _____________________ Annexation Area." 6. COMMENT: Add the above statement and add in the blank spaces "C9-59-19" for the ordinance number and "North To Roger Road and East to Kolb Road" for the annexation area. 2-07.5.3.E Assurances The following ASSURANCE block must be placed on the plat's first sheet. ASSURANCES "This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy." City of Tucson Planning and Development Services Department Director City of Tucson Engineer 7. COMMENT: Under the Assurance text block, revise the City Engineer signatory title to "City Of Tucson Engineer" 2-07.5.4 Proposed Subdivision Information Provide the following information on the plat: 2-07.5.4.A. Indicate the name and width of each street, alley, easement (type), and drainage way within the subdivision boundary being created by this plat. Label each as public or private, along with the appropriate dedication notation; 8. COMMENT: As noted in comment 4, add the dimension lines to the street right of ways. 2-07.5.6 Protective Covenants Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will: 2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and 9. COMMENT: Will this project include CC&R's? 10. COMMENT: Incorporate both Final Plat Sheets into one PDF file for the next submittal. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 07/10/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | S19-004 1. The Plat cannot be approved until the Development Plan/Tentative Plat (DP19-0138) is approved. 2. This property is not a minor subdivision. Update the title box to reflect this as a Final Plat. 3. Address exceptions 4, 5 and 6 of schedule B, Section II of the Title Report. If these recorded documents encumber the properties, show them on the plat. 4. Show dedication of the future right-of-way for Stone Avenue. (AM 2-06.4.9.I) 5. Show a tie from the proposed subdivision to a section corner or quarter corner. 6. Add a note indicating floodplain use permits will be required for the parcels with floodplain. (AM 2-07.5.E) Remove note 8. 7. Show the floodplain boundaries in a surveyable and readily traceable manner. (AM 2-07.5.4.F) 8. Provide appropriate dedication statements. (AM 2-07.5.3.B) 9. Revise the signature line from "City of Tucson PDSD Engineering Administrator" to "City of Tucson City Engineer." 10. Ensure that all required plans and documents are submitted with the next submittal. The plat must be submitted a PDF file. |
| 07/10/2019 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | According to your file this is a Tentative Plat, and we only review Final Plats. Suzanne Gilpin, GIS Cartographer Pima County Assessor suzanne.gilpin@pima.gov (520) 724-4387 FROM: Ada Janson, GIS Cartographer, Pima County Assessor's Office Plat does not meet Assessor's Office requirements. PLEASE PROVIDE A FINAL PLAT FOR REVIEW. |
| 07/10/2019 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | Project S19-004 Final Plat for Mohave Stone at 3402 N Stone AV still has an amount due ($197). The invoice was issued on 6/5/2019. Thank you Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV, Tucson, AZ 85701 (520) 724-9623 |
| 07/11/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE The reviews have been completed and a resubmittal is required. Fee Balance: $1,116.50 (see the Balance column in the image below). NOTE: We now have an online payment option β itβs available for some permits (not all). Below is the link. If unable to use this option, you may pay in person or mail a payment. Please pay the total fees, or Review Fees at a minimum, at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM) or mail a check (payable to City of Tucson β address is shown below) prior to the completion of the first review. Include the Activity Number on your check. Link to City of Tucson, Online Payments: https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records Activity Number: S19-004 Project Description: FINAL PLAT - Mohave Stone, Lots 4-A, 4-B, and 4-C. A resubdivision of Lot 4, Block 2 of Sawtelle Place. For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) After all corrections are made, please name your 2nd submittal documents accordingly, for example: 2_Plan_Set. Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (listing how all comments were addressed) 2) Complete Plan Set (all pages, full set) 3) Any other items requested by review staff After resubmittal, the plans will re-enter the standard 20-working-day review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/11/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |