Plan Number: S19-003
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S19-003
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/28/2019 SBEASLE1 START PLANS SUBMITTED Completed
01/28/2019 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
01/28/2019 ALEXANDRA HINES PIMA COUNTY PAG - PIMA ASSN OF GOVTS Passed
01/28/2019 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved 01/28/19 email:
No existing or proposed Tucson Parks and Recreation facilities are affected by this Block Plat.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
01/28/2019 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed This agency is being notified for their information only. A response is not required.
01/30/2019 ED ABRIGO PIMA COUNTY ASSESSOR Approved January 28, 2019
TO: CDRC Office, Subdivision Review, City of Tucson
FROM: Julieann Arechederra, GIS Cartographer, Pima County Assessor's Office

RE: Assessor's Review and Comments Regarding: BIO-LIFE PLASMA SERVICE CENTER S19-003
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
X Plat meets Assessor's Office requirements.

COMMENTS:
" THE TITLE BLOCK MUST BE IN THE LOWER RIGHT HAND CORNER. IT MUST HAVE THE NUMBER OF LOTS OR UNITS OR BLOCKS OR ANY COMBINATION OF THESE. IT MUST HAVE THE COMMON AREAS LISTED, IF THERE ARE ANY. IT MUST HAVE THE SECTION, TOWNSHIP AND RANGE AND IF IT IS A RESUBDIVISION, IT MUST MENTION THE PLAT NAME AND THE MAP AND PLAT.
" THE LOCATION MAP MUST BE IN THE UPPER RIGHT HAND CORNER AND MUST HAVE THE SECTION, TOWNSHIP AND RANGE. THE PROJECT AREA SHOULD BE OUTLINED OR HAVE AN ARROW POINT TO IT.
01/31/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved 1/31/19
This was processed in July of 2018 for Rick Engineering. See attached.
Kellie Anderson
Administrative Assistant
Tucson Water-New Development
Ph: (520) 837-2165
-----------------------------------------------------
July 27, 2018
Rick Engineering Company
6150 N. 16th St.
Phoenix, AZ 85016
Attn: Kathi Walp
SUBJECT: Water Availability for Project: 8019 E. Golf Links Rd , APN: Multiple Parcels,
Case #: WA2551 , T-14 R-15 S-21 , Lots: 0,11-19,21-29,31-39,41-49,51-57 , Location Code: TUC , Total Area: 3.94 , Zoning: C-1
WATER SUPPLY
Tucson Water will provide water service to this project based on the subject zoning of the above parcels. Tucson Water has an assured water supply (AWS) designated from the State of Arizona Department of Water Resources (ADWR). An AWS designation means Tucson Water has met the criteria established by ADWR for demonstration of a 100-year water supply - it does not mean that water service is currently available to the subject project.
WATER SERVICE
The approval of water meter applications is subject to the current availability of water service at the time an application is received. The developer shall be required to submit a water master plan identifying, but not limited to: 1) Water Use; 2) Fire Flow Requirements; 3) Offsite/Onsite Water Facilities; 4) Loops and Proposed Connection Points to Existing Water System; and 5) Easements/Common Areas.
Any specific area plan fees, protected main/facility fees and/or other needed facilities' cost, are to be paid by the developer. If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be financially responsible for modifying or enhancing the existing water system to meet those needs.
This letter shall be null and void two years from the date of issuance.
Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development.
If you have any questions, please call New Development at 791-4718.
Sincerely,
Richard A. Sarti, P.E.
Engineering Manager
Tucson Water Department
01/31/2019 SBEASLE1 PIMA COUNTY WASTEWATER Passed Provide approval of P19WS00007 in submittal.
02/05/2019 MASHFOR1 COT NON-DSD FIRE Approved
02/19/2019 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the Biolife Block Plat submitted on January 28, 2019. Easements for TEP equipment to serve future development will be obtained by separate instrument.
If there any questions, please contact me at 520-917-8744.
Thank you,

Mary Burke, Right of Way Agent III
Tucson Electric Power Co.
Land Resources - RC 131, 3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744, Cell - 520-401-9895
mburke@tep.com
02/19/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
02/20/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
02/20/2019 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
02/21/2019 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Completed
02/25/2019 EHAMBLI1 ZONING HC REVIEW Approved
02/25/2019 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC Transmittal

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Elisa Hamblin, AICP; Principal Planner
PDSD Zoning Review Section

PROJECT: Bio-Life Plasma Services Center Block Plat (Abandonment)
Block Plat (1st Review)
S19-003

TRANSMITTAL DATE: February 25, 2019
DUE DATE: February 21, 2019

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

1. 2-07.5.1.A.1. - A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile. Include the scale with the location map.
2. 2-07.5.1.A.2. - On the location map, the project site must be approximately centered within a one square mile area;
3. 2-07.5.1.A.3. - On the location map, label the section, township, and range; section corners; north arrow; and the scale;
4. 2-07.5.1.A.4. - On the location map, label subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and,
5. 2-07.5.1.F. - Place a north arrow on each sheet in the upper right corner with the scale of the drawing beneath the arrow.
6. 2-07.5.1.H. - Include associated case numbers (S19-003 and T18SE00067) in the lower right corner of the plat next to the title block.
7. 2-07.5.2.H. - Correct General Note 8, there is a typo in the word "There".
8. 2-07.5.2.I. - If the subdivision was the result of a rezoning case and did not require submittal and review of a tentative plat, add the following note: "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public."
9. 2-07.5.2.J. - Add the following note: "This subdivision is subject to Ordinance No. 6372 which established zoning in the 22nd St. - Pantano Parkway Annexation Area."
10. 2-07.5.3.A. - On the Certification of Survey standard paragraph, a line must be included for the printed name and signature of the registered land surveyor separate from the seal.
11. 2-07.5.3.B.3. - Add the following hold-harmless statement: "(I/We), the undersigned, do hereby hold harmless the City of Tucson, its successors and assigns, their employees, officers, and agents from any and all claims for damages related to the use of the property depicted on this plat now and in the future by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall."
12. 2-07.5.3.B.4. - Add the signature lines for the property owners. The number of signatures depends on the number of persons who have fee title interest according to a title report current within 30 days of recordation of the proposed plat.
13. 2-07.5.3.C. - If applicable, the following BENEFICIARY block must be included on the title page.
BENEFICIARY
"The beneficiary of (Title Company Name and Trust Number) is (Name and Address)."
14. 2-07.5.3.E. - Revise the Assurance title block to read as follows:
"This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy."

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
02/27/2019 LOREN MAKUS ENGINEERING REVIEW Approved
02/27/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The review has been completed and a resubmittal is required.
Activity Number: S19-003
Project Description: BLOCK PLAT - BIOLIFE PLASMA SERVICES CENTER, ABANDONMENT OF BARRIO PANTANO, Lots 1-57, a residential cluster project, common area "A" (street), "B" (drainage), "C" (recreation) and "D" (landscape).
To see review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
Prepare a Comment Response Letter detailing changes to the plan and which review comments are being addressed. After the necessary corrections have been made, submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. Enter the Activity Number in the Project Description field and name the file as directed, for example, second submittal: 2_Plan_Set.pdf. The plans will then re-enter a 20-working-day review cycle.
1) Comment Response Letter
2) Corrected plan set with all documents
3) Items requested by review staff
Please pay the assessed fees, or Review Fees at a minimum, at the permit counter or mail a check (payable to City of Tucson – address is shown below) prior to the completion of the next review. Include the Activity Number on your check stub. The fee balance is $ 2,099.79.
John Van Winkle, copied, is the Project Manager to contact with any questions, email: JohnVanWinkle@TucsonAz.gov or phone: (520) 837-5007. Thank you.

Sharon Beasley
City of Tucson
Planning and Development Services
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
03/25/2019 KAY MARKS PIMA COUNTY ADDRESSING Approved The Addressing Review S19-003 Block Plat for Biolife Plasma Services is Approved by Pima County Addressing.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 4th Floor
Tucson, AZ 85701
(520) 724-7570

Final Status

Task End Date Reviewer's Name Type of Review Description
02/27/2019 SBEASLE1 OUT TO CUSTOMER Completed