Plan Number: S18-080
Parcel: Unknown

Address:
1129 E 7TH ST

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S18-080
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/06/2018 QJONES1 START PLANS BEING WALKED THRU Completed
09/06/2018 AHINES2 H/C SITE REVIEW Approved
09/06/2018 ALEXANDRA HINES ZONING REVIEW Reqs Change FROM: Alexandra Hines, Lead Planner

PROJECT:
S18-080 (revise DP18-0050 to reflect)

TRANSMITTAL: September 6, 2018

COMMENTS: Reciprocal Access Agreement provide and to be recorded with lot split.

The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback is the greater of six (6) feet, or three-fourths (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a).

The proposed setback is:
Thirteen (13) feet from east property line (proposed in S18-080), required is fourteen (14) feet for Lot 1 (east lot).
Thirteen (13) feet from west property line (proposed in S18-080), required is fourteen (14) feet for Lot 2 (west lot).
09/06/2018 ALEXANDRA HINES ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Elisa Hamblin, AICP
Lead Planner

PROJECT:
S18-080 (revise DP18-0050 to reflect)
1129 E 7th St
The Graymont

TRANSMITTAL: September 20, 2018
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6., .9 and .10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

The proposed setback is:
" Thirteen feet two inches (13'2") from east property line (proposed in S18-080), required is thirteen feet six inches (13'6") for lot 1 (east lot).
" Thirteen feet two inches (13'2") from west property line (proposed in S18-080), required is thirteen feet six inches (13'6") for lot 2 (west lot).
09/06/2018 ALEXANDRA HINES ZONING REVIEW Reqs Change FROM: Alexandra Hines, Lead Planner

PROJECT:
S18-080 (revise DP18-0050 to reflect)
1129 E 7th St
The Graymont

TRANSMITTAL: October 5, 2018
COMMENTS: Reciprocal Access Agreement provide and to be recorded with lot split.

The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback is the greater of six (6) feet, or three-fourths (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The proposed setback is:
" Thirteen (13) feet from east property line (proposed in S18-080), required is thirteen feet six inches (13.5) for Lot 1 (east lot) based on eighteen feet height.
" Thirteen (13) feet from west property line (proposed in S18-080), required is thirteen feet six inches (13.5) for Lot 2 (west lot) based on eighteen feet height.
09/07/2018 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/07/2018 LOREN MAKUS ENGINEERING REVIEW Approved
09/07/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide a separate water meter for each lot.
2. Clarify how the individual units will be classified: condominiums or townhouses? If the units are townhouses, the water distribution and the building drains will have to be modified to independently serve each townhouse.
11/26/2018 KROBLES1 ZONING-RECORDATION REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
11/26/2018 KROBLES1 OUT TO CUSTOMER Completed