Plan Review Detail
Review Status: Completed
Review Details: MINOR SUBDIVISION REVIEW
Plan Number - S18-067
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/07/2018 | KROBLES1 | START | PLANS SUBMITTED | Completed | |
| 08/07/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 08/07/2018 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 240 N STONE AVENUE Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Janice Wagner GIS Cartographer Pima County Assessor's Office DATE: July 16, 2018 RE: Assessor's Review and Comments Regarding: THORPE ACRES LOTS 1-A AND LOT 2-A /S18-067 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. ____X___ Plat does not meet Assessor's Office requirements. COMMENTS: " THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER MUST SHOW IT IS A "RESUBDIVISON" OF LOT 12 & 13 OF BLOCK 15 OF TUCSON HEIGHTS AMENENDED ETC.... NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 08/07/2018 | KLEE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | Proposal is less than 6 lots. |
| 08/07/2018 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 08/07/2018 | KELLY LEE | UTILITIES | SOUTHWEST GAS | Passed | Agency notified for information only. |
| 08/07/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | S18-067 1) Show on supplemental site plan the shortest distance from the existing building to the proposed new lot line so that required setbacks can be verified. In this case the shortest distance appears to be from the north-east corner of the building to a diagonal line which is shown as being 18.75' in length. 2) Under Certification of Title remove the box and quotation marks around the first paragraph 3) Per City of Tucson Administrative Manual (AM) section 2-07.5.5.A, provide at least one property corner tie to a section corner, quarter section corner, or an established city or county monument. John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 08/07/2018 | EHAMBLI1 | ZONING | REVIEW | Reqs Change | CDRC Transmittal TO: Planning and Development Services Department Plans Coordination Office FROM: Elisa Hamblin, AICP Lead Planner PDSD Zoning Review Section PROJECT: Thorpe Acres Lots 1-A and 2-A, 429 E. Lester St. Minor Subdivision (1st Review) S18-067 TRANSMITTAL DATE: August 6, 2018 DUE DATE: August 8, 2018 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. 2-07.5.1.A. The project location map must include the project site approximately centered within one square mile area. Label the section, township, and range; section corners; north arrow; and the scale. 2. 2-07.5.1.D. Place the words "SEQ#________" in both the upper and lower right corners outside the margin line on both sheets. The blanks will be completed by the Pima County Recorder's Office at the time of recordation. 3. 2-07.5.1.E. - Revise the title block on sheet 2. "BOOK 2" and "SECTION" both have typos. Ensure the title block on sheets 1 and 2 are the same. 4. 2-07.5.1.H. - The subdivision case number (S18-067) must be placed in the lower right corner of the plat next to the title block. 5. 2-07.5.3.B.2 - Include one of the four dedication language samples shown in this section of the code. 6. 2-07.5.3.C - If applicable, include the beneficiary block on the title page. 7. 2-07.5.3.E. - Revise the last signature line on the Assurances block to read "City of Tucson PDSD Engineering Administrator". 8. 2-07.5.4.A. - On the plat, indicate the name and width of each easement (type) within the subdivision boundary being created by this plat. Label each as public or private, along with the appropriate dedication notation. 9. 2-07.5.4.E. - Provide the required setbacks, such as erosion hazard, drainage, etc. on the plat. The height of the existing home must be shown to determine the 8' setback is sufficient. The ramada in the rear yard cannot cross the new property line as it will not meet setbacks. 10. 2-07.5.4.H.- If applicable, show no-vehicular access easements. If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 08/07/2018 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 08/07/2018 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | Tucson Electric Power Co., (TEP) has reviewed and approves the final plat submitted on July 13, 2018. Costs for relocation of existing overhead facilities will be at owner’s expense. Easements for TEP facilities may be required to accommodate new development. If there are any questions, please contact me at 520-917-8744. Thank you, Mary Burke Right of Way Agent III Tucson Electric Power Co. Land Resources – RC 131 3950 E. Irvington Road Tucson, AZ 85714-2114 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 08/07/2018 | KAY MARKS | PIMA COUNTY | ADDRESSING | Passed | Good afternoon, I’m not sure what happened to this one. Given the nature of the split I will waive review of this project. I will invoice the applicant for a new address and go from there. The proposed address for Lot 1-A will be 431 E Lester ST. Let me know if you have any questions. Thanks Nicholas Jordan Addressing Specialist Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
| 08/07/2018 | EHAMBLI1 | HC SITE | REVIEW | Approved | |
| 08/07/2018 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Passed | |
| 08/07/2018 | KELLY LEE | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | |
| 08/08/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 08/10/2018 | KELLY LEE | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/05/2019 | AHINES2 | OUT TO CUSTOMER | Completed |