Plan Number: S18-062
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S18-062
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2018 KELLY LEE START PLANS SUBMITTED Completed
07/02/2018 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
07/13/2018 KELLY LEE UTILITIES SOUTHWEST GAS Passed agency notified for information only.
07/13/2018 KELLY LEE OTHER AGENCIES U. S. POST OFFICE Passed agency notified for information only.
07/13/2018 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Completed
07/13/2018 KELLY LEE OTHER AGENCIES PIMA ASSN OF GOVTS Passed agency notified for information only.
07/18/2018 ANDREW CONNOR LANDSCAPE REVIEW Approved
07/19/2018 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera for Steve Shields - Principal Planner
PDSD Zoning Review Section

PROJECT: Broadway Place Blocks 1, 2 and 3
Final Plat (1st Review)
S18-062

TRANSMITTAL DATE: July 19, 2018

DUE DATE: July 25, 2018

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013)



2-07.5.1.H - The Subdivision Case number assigned to the final plat and the DP case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

1. COMMENT: List the Subdivision case number S18-062 next to the title block of both sheets. If there is an associated DP with this plat list as reference the DP case number next to the title block of both sheets.


2-07.5.2.D If the property is subject to conditions of rezoning, add the following note: "This plat is subject to the conditions of rezoning case number C9-__-__, unless superseded by a subsequent rezoning ordinance."

2. COMMENT: Add on the cover the information related to the rezoning case associated with the site as noted by the standard above.


2-07.5.4.B - Identify each block or lot within the subdivision boundary by number, and include the square footage of each;

3. COMMENT: On sheet 2, the L2 was not listed. On sheet 2, block 3 is labeled with L3 annotation on the two short property line segments at the main entrance. Revise as required.


2-07.5.6 - Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will:
2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and

4. COMMENT: List as a general note, the recorded document and recording information that includes language that allows for cross access, parking etc.


If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
07/19/2018 DAVID RIVERA ZONING HC REVIEW Approved
07/20/2018 KAY MARKS PIMA COUNTY ADDRESSING Reqs Change ***See attachment in documents table on PRO.***

Pima County Addressing is returning S18-062 Panera Bread Drive Through Addition Block Plat / 1st Submittal for corrections. Please see the attached plan for comments.

Thank you

Nicholas Jordan
Addressing Specialist
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
07/20/2018 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the final plat submitted on June 26, 2018. Costs for removal or relocation of existing electrical facilities, if required, will be billable to the developer. Please call the New Construction Department at 520-918-8300 to apply for service. Submit a final set of approved plans including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required, they will be obtained by separate instrument.

Please contact me at 520-917-8744 should you have any questions.

Thank you,

Mary Burke
Right of Way Agent III
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
07/24/2018 JIM EGAN COT NON-DSD FIRE Approved
07/25/2018 JOHN VAN WINKLE ENGINEERING REVIEW Approved
07/25/2018 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approv-Cond This property is subject to conditions of rezoning; add the following note: "This plat is subject to the conditions of rezoning case number C9-76-33, unless superseded by a subsequent rezoning ordinance." TSM 2-07.5.2.D

Please also add the rezoning case number and relevant development package case number DP18-0153 to the bottom right corner.
07/26/2018 ALEXANDRA HINES PIMA COUNTY WASTEWATER Passed There will be no review required for this block plat. All onsite sewer is private and there is no public sewer being proposed for the drive-thru addition to Panera Bread.

Regards,

Joseph

Joseph Godoy
Site Division Manager
Pima County Development Services
201 N. Stone Ave
Tucson, AZ 85701
joseph.godoy@pima.gov
(520) 724-6756
07/26/2018 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
240 N STONE AVENUE
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson


FROM: Ada Griffin
GIS Cartographer
Pima County Assessor's Office


DATE: July 26, 2018


RE: Assessor's Review and Comments Regarding:

S18-062 1ST SUBMITTAL PANERA BREAD DRIVE THROUGH



* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
___X___ Plat does not meet Assessor's Office requirements.

COMMENTS:



" ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION.



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
07/27/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Approv-Cond CITY DEVELOPMENT REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

July 27, 2018
Tri Miller
Rick Engineering Company
3945 E Fort Lowell Rd - Suite 111
Tucson, AZ 85712

Subject: S18-062 Broadway Place Block 1, 2, & 3 Final Plat

Dear Tri,

The above referenced project has been CONDITIONALLY APPROVED by the City Development Review Committee. Please make any necessary corrections and submit the following documents:

1 Executed Final Plat Double Matte Océ or Photo Mylar.

1 Title reports current within the last thirty (30) days.

1 Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a flat $4.00 handling fee, along with Consent to Dedicate and CC&R fees if applicable. Consent to Dedicate and CC&R fees are $10.00 for the first 5 pages and $1.00 for each additional page. If the Consent to Dedicate is also a fixture filing, there is an additional $9.00 fee. If you are unsure of the fees, please call the County Recorders Office at 520-740-4350.

1 Original Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable).

1 Copied Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable).

1 CD with Digital Copy in PDF Format of signed Plat, CC&R's (if applicable) and Assurances (if applicable).

1 Provide the property owner(s) and engineering mailing address on a sheet of paper in the submittal to receive proper notification 1 week prior to the Mayor and Council Meeting (if no assurances).

The Planning and Development Services Department makes sure the Assurances (if applicable) are reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Should you have any questions, please call me at (520) 837-6975 or Kelly Lee at (520) 837-6999.

Sincerely,


Alexandra Hines
Lead Planner

All comments for this case are available on our website at www.tucsonaz.gov/PRO.

Via Permits Plus/E-mail

Final Status

Task End Date Reviewer's Name Type of Review Description
07/27/2018 AHINES2 OUT TO CUSTOMER Completed