Plan Number: S18-030
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S18-030
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2018 KROBLES1 START PLANS SUBMITTED Completed
05/07/2018 ANDREW CONNOR LANDSCAPE REVIEW Approved
05/07/2018 ALEXANDRA HINES PIMA COUNTY WASTEWATER Reqs Change The applicant is responsible for obtaining review and approval of the final plat from County at sewer@pima.gov prior to City approval. Please provide approval in submittal.
05/07/2018 AHINES2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed Water acceptability for proposal less than 6 lots.
05/07/2018 MARTIN BROWN COT NON-DSD FIRE Approved
05/07/2018 ALEXANDRA HINES UTILITIES SOUTHWEST GAS Passed Agency notified for information only.
05/07/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change S18-030
1) The plan submitted for review does not meet the minimum standards as outlined in the City of Tucson Administrative Manual (AM) section 2-07. Review AM Section 2-07 and submit a drawing that is in substantial compliance with the standards outlined. See the link below
http://library.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/tucsonazunifieddevelopmentcode?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az
2) Note that when adding assurance 2-07.5.3.E "City of Tucson PDSD Engineering Administrator" needs to change to "City of Tucson City Engineer"
3) Provide a survey tie from the subdivision to a section or ¼ corner

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
05/07/2018 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera for Steve Shields - Principal Planner
PDSD Zoning Review Section

PROJECT: Minor Subdivision
Final Plat (1st Review)
S18-030

TRANSMITTAL DATE: May2, 2018

DUE DATE: May 3, 2018

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013)

2-07.3.0 SUBMITTAL TIMING
Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.


1. COMMENT: The plan submitted for review does not meet the minimum standards as outlined in the Administrative Manual 2-07. Review A.M. Section 2-07 and submit a drawing that is in substantial compliance with the standards outlined in this section. See the link below

http://library.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/tucsonazunifieddevelopmentcode?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

2. COMMENT: Include a supplemental site plan sheet for the overall development as reference.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
05/07/2018 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
05/07/2018 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
240 N. Stone Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR

TO: City of Tucson Development Services

FROM: Suzanne Gilpin
GIS Cartographer
Pima County Assessor's Office
(520)724-4387

DATE: April 24, 2018

RE: Assessor's Review and Comments Regarding Final Plat-
S18-030 Respectful 12345/1st Submittal
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Plat meets Assessor's Office requirements.
__X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" The title block must be in the lower right hand corner: It must have a subdivision name, and it must have the number of lots or units or block or elements or any combination of these. It must have the common areas listed, if there are any. It must have the section, township and range and if it is a resubdivision, it must mention the plat name and the map & plat.
" The location map must be in the upper right hand corner and must have the section, township and range. The project area should be outlined or have an arrow pointing to it.
" General notes must have the gross area of the subdivision, the number of lots, the number of miles of new road, public or private, even if the number is 0 and the Basis of Bearings.
" There must be a section tie, with a bearing and dimension from the section corner or quarter corner to the point of tie on the subdivision.
" The perimeter line must be solid and the heaviest line weight on the plat. The lot lines and common area lines must be solid and the next heaviest. Lines for erosion setbacks, floodplain lines etc. should be the lightest line weight and be dashed or dot-dashed.
" All Adjacent subdivisions should be named, with map and plat in the appropriate areas around the subdivision.
" No ownership or approval shown on plat.
NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
05/07/2018 DAVID RIVERA HC SITE REVIEW Reqs Change
05/07/2018 KAY MARKS PIMA COUNTY ADDRESSING Approved S18-030 Respectful 12345 / 1st Submittal is Approved by Pima County Addressing. Once deeds are recorded the existing addresses 1516 and 1520 E Waverly St will be retired and the Pending Addresses shown on the attached pdf will be issued for the new lots.

Please let me know if you have any questions.

Thank you,



Robin Freiman

Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor
Tucson, AZ 85701

(520) 724-7570
05/08/2018 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approv-Cond Tucson Electric Power Co., (TEP) has reviewed the survey for the minor subdivision Respectful 12345, and has no objection to the lot split. Since the plat is not in standard format, please include TEP on the 2nd submittal.



If you have any questions, please contact me at 520-917-8744.



Thank you,



Mary Burke

Right of Way Agent III

Tucson Electric Power Co.

Land Resources – RC 131

3950 E. Irvington Road

Tucson, AZ 85714-2114

Office - 520-917-8744

Cell - 520-401-9895

mburke@tep.com
05/08/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/09/2018 KELLY LEE ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
06/20/2018 LPEREZ2 OUT TO CUSTOMER Completed