Address:
6026 E 29TH ST

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S17-068
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2017 KROBLES1 START PLANS SUBMITTED Completed
11/21/2017 ALEXANDRA HINES UTILITIES SOUTHWEST GAS Passed Agency notified for information only.
11/21/2017 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
240 N STONE AVENUE
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR

TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Janice Wagner
GIS Cartographer
Pima County Assessor's Office

DATE: November 21, 2017

RE: Assessor's Review and Comments Regarding:

MINOR LAND SUBDIVISION - FIRST FINAL REVIEW

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
___X____ Plat does not meet Assessor's Office requirements.

COMMENTS:

" THE LOCATION MAP MUST BE IN THE UPPER RIGHT HAND CORNER AND MUST HAVE THE SECTION, TOWNSHIP AND RANGE. THE PROJECT AREA SHOULD BE OUTLINED OR HAVE AN ARROW POINT TO IT.

" THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION.

" THE PERIMETER LINE MUST BE SOLID AND HEAVIEST LINE WEIGHT ON THE PLAT. THE LOT LINES AND COMMON AREA LINES MUST BE SOLID AND THE NEXT HEAVIEST. LINES FOR EROSION SETBACKS, FLOODPLAIN LINES ETC. SHOULD BE THE LIGHTEST LINE WEIGHT AND BE DASHED OR DOT-DASHED.

" THERE MUST BE BEARINGS AND DIMENSIONS FOR THE PERIMETER AND ALL LOT LINES AND ALL COMMON AREAS. (FINAL PLAT)

" ALL LOTS MUST BE NUMBERED AND HAVE SQUARE FOOTAGE. IF THE AREA IS TOO SMALL, THEY CAN HAVE A TABLE TO THE SIDE FOR THE SQUARE FOOTAGE.

" ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION.

" CHECK OWNERSHIP TO MAKE SURE IT MATCHES WHAT WE HAVE.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
11/21/2017 AHINES2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed Proposed subdivision has assured water supply since less than 6 lots.
11/21/2017 ALEXANDRA HINES OTHER AGENCIES U. S. POST OFFICE Passed Agency notified for information only.
11/21/2017 KAY MARKS PIMA COUNTY ADDRESSING Approved S17-068 E 29th St / 1st Submittal is Approved by Pima County Addressing.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
11/21/2017 ALEXANDRA HINES OTHER AGENCIES PIMA ASSN OF GOVTS Passed Agency notified for information only.
12/05/2017 JIM EGAN COT NON-DSD FIRE Approved
12/05/2017 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Completed
12/13/2017 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/13/2017 ANDREW CONNOR NPPO REVIEW Approved
12/13/2017 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
12/18/2017 SSHIELD1 HC SITE REVIEW Passed
12/18/2017 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: 6026 E. 29th Street
Final Plat (1st Review)
S17-068

TRANSMITTAL DATE: December 18, 2017

DUE DATE: December 18, 2017

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS

2-07.5.0 CONTENT REQUIREMENTS

5.1 General

1. 2-07.5.1.A - The location map shall be drawn at a scale of three inches equals one mile

2. 2-07.5.1.A.1 Show the project site approximately centered within a one square mile area on the location map.
3. 2-07.5.1.A.2 Label the section, township, and range; section corners; north arrow; and the scale on the location map.

4. 2-07.5.1.A.3 Label all subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area on the location map.

5. 2-07.5.1.B As the provided "RECORD OF SURVEY" will not be recorded with the final plat remove it from the set.
6. 2-07.5.1.D Place the words "SEQ#________" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation.

7. 2-07.5.1.E.1 Provide a name for the subdivision and the number of lots within the title block.

8. 2-07.5.1.H Place the subdivision case number, S17-068 in the lower right corner of the plat next to the title block.

9. 2-07.5.1.I Provide a legend which shows and describes all symbols used on the drawing must be placed on either the first sheet of the plat or the first sheet which contains all or part of the subdivision drawing.

2-07.5.3 Standard Paragraphs
The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal.

10. COMMENT: Revise the "APPROVAL" block to match what is shown in Administrative Manual 2-07.0 Section 2-07.5.3.D.


If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
12/19/2017 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Provide the notes required by Administrative Manual Section 2-07.0.0. (Modify the assurances signature lines to provide a signature for the City of Tucson City Engineer instead of the PDSD Engineering Administrator.
2. Provide tie to a section corner or quarter corner.
3. Clarify in the notation that the right-of-way dedication is by this plat.
4. Clarify the assurances mechanism to be used for this subdivision. Provide the appropriate notes.
5. Remove the unnecessary line work, such as the existing fence, the curb and curb openings.
12/20/2017 ALEXANDRA HINES PIMA COUNTY WASTEWATER Reqs Change The applicant is responsible for obtaining review and approval with PC wastewater by emailing sewer@pima.gov. Provide approval is final plat submittal.
12/20/2017 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the final plat submitted on November 21, 2017.

Please call the New Construction Department at 520-918-8300 to apply for service. Submit a final set of approved plans including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required, they will be obtained by separate instrument.

Please contact me at 520-917-8744 should you have any questions.

Thank you,

Mary Burke
Right of Way Agent III
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
12/20/2017 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this Final Plat.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
12/20/2017 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
01/11/2018 KROBLES1 OUT TO CUSTOMER Completed