Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S17-047
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/22/2017 | ARUIZ1 | START | PLANS SUBMITTED | Completed | |
| 08/25/2017 | AHINES2 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | Proposal under 6 lots. No response needed from Tucson Water. |
| 08/25/2017 | ALEXANDRA HINES | UTILITIES | SOUTHWEST GAS | Passed | Notified for information only. No response needed from agency. |
| 08/28/2017 | ALEXANDRA HINES | PIMA COUNTY | WASTEWATER | Approved | August 28, 2017 To: Benedict Bautista Jeff Behrana, P.E. Optimus Civil Design Group, LLC Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: _______________________________________________ Debbie Ketchem, Civil Engineer Assistant - Sr. Development Liaison Unit Subject: Approval Letter - sewer elements only Final Plat - 1st Submittal, P17WS00073 (S17-047) Pima County Regional Wastewater Reclamation Department (PCRWRD) hereby "Approves" The Bridges - Block 14, Lots 1-2 as submitted on August 23, 2017. This approval is for elements related to the sewer system only. Approval will need to be reobtained if the scope of the project changes that may impact the sewer. This also could include the language in the Dedication as well as easements for utilities/sewers. We request the applicant to contact RWRD-DLU to discuss what action if any shall be required. If the jurisdiction requires RWRD signature on the Mylar and there has been changes without communication it could delay the obtaining of RWRD's signature. Do not hesitate to contact me if you have any questions at (520) 724-6481. Cc: Lorenzo Hernandez, P.E., C.E. Manager, RWRD Francisco Galindo, P.E., RWRD |
| 08/28/2017 | ALEXANDRA HINES | PIMA COUNTY | ADDRESSING | Reqs Change | ***Attachment is in Documents folder on PRO.*** S17-047 The Bridges - Block 14 (Discount Tire) / 1st Submittal is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you, Robin Freiman Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 09/12/2017 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principal Planner PROJECT: The Bridges at Block 14 - Final Plat Final Plat (1st Review) S17-047 TRANSMITTAL DATE: September 12, 2017 DUE DATE: September 20, 2017 COMMENTS: The Zoning review section conditionally approves the plat subject to the following comment. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements. 1. 2-07.5.1.H - Provide the final plat case number, S17-047, adjacent to the title block on all sheets. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 09/12/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 09/18/2017 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | Tucson Electric Power Co., (TEP) has reviewed and approves the final plat for The Bridges – Block 14 submitted on 8-25-17. If easements for TEP facilities are required for new development, they will be obtained by separate instrument. If you have any questions, please contact me at 520-917-8744. Thank you, Mary Burke Right of Way Agent III Tucson Electric Power Co. Land Resources – RC 131 3950 E. Irvington Road Tucson, AZ 85714-2114 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 09/20/2017 | KELLY LEE | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approv-Cond | September 20, 2017 Dear Ms. Hines, Thank you for the opportunity to comment on S17-047, The Bridges - Block 14 (Discount Tire); 1st Submittal, a final plat application. This final plat application is located north of Duvall Vista, west of the intersection of South Campbell Avenue and East Cochise Vista, and east of South Kino Parkway. This project submittal does not propose any development. The Tucson Airport Authority has no additional comments to submit on S17-047. The Tucson Airport Authority provided comments on submittal DP17-0204, dated 9/8/17, which is directly associated with S17-047. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, Senior Airport Planner cc file |
| 09/20/2017 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 240 N STONE AVENUE Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Janice Wagner GIS Cartographer Pima County Assessor's Office DATE: September 20, 2017 RE: Assessor's Review and Comments Regarding: S17-047 THE BRIDGES-BLOCK 14-FIRST FINAL REVIEW * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. __X_____ Plat does not meet Assessor's Office requirements. COMMENTS: " ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 09/20/2017 | KELLY LEE | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/12/2017 | QJONES1 | APPROVAL SHELF | Completed |
| 10/12/2017 | QJONES1 | REJECT SHELF | Completed |
| 10/12/2017 | QJONES1 | OUT TO CUSTOMER | Completed |