Plan Number: S17-023
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S17-023
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2017 KROBLES1 START PLANS SUBMITTED Completed
10/10/2017 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)



FROM: Ada Griffin
GIS Cartographer
Pima County Assessor's Office


DATE: October 9, 2017


RE: Assessor's Review and Comments Regarding:

S17-023 2nd review Final plat Camino Modern

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
___X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" THE PERIMETER LINE MUST BE SOLID AND HEAVIEST LINE WEIGHT ON THE PLAT. THE LOT LINES AND COMMON AREA LINES MUST BE SOLID AND THE NEXT HEAVIEST.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
10/13/2017 ALEXANDRA HINES PIMA COUNTY ADDRESSING Approv-Cond The 2nd Submittal Camino Modern Final Plat (S17-023) is Conditionally Approved by Pima County Addressing subject to the mylars showing the correct directional prefixes. The streets must be labeled E Avant Garde Wy, E Ultra Dr, and E Innovative Dr.

Please let me know if you have any questions.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
10/24/2017 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera for Steve Shields - Principal Planner
PDSD Zoning Review Section

PROJECT: Camino Modern, Lots 1-54 and Common Areas, "A", "B", "C"
Final Plat (2nd Review)
S17-023

TRANSMITTAL DATE: October 24, 2017

DUE DATE: October 24, 2017

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. Follow Up To Previous Comment 3: Per your response to the previous comment 3, the site area has been revised to match the area listed on the tentative plat. Clarify if the area on the tentative plat has also been revised. The area listed on the last copy of the tentative plat files on line at PDSD do not match what has been listed on the latest revision of the final plat.

PREIOVUS COMMENT 3: 2-07.5.2.A - Clarify why the square footage shown under General Note 1, 226,460 sf is different from what is shown under the tentative plat General Note 4, 226,388 sf.


2. Follow Up Comment to Previous Comment 4: per discussion with staff, the information related to the legal description under the recitals section A shall be listed on the cover sheet of the CC&R's.

2-07.5.6 Protective Covenants
Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will:
2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and

PREVIOUS COMMENT 4: Provide a copy of the CC&R's with your next submittal.


3. Follow Up To Previous Comment 5: As of this review of the Final Plat the tentative plat has not been approved. AS noted in the previous comment, the final plat cannot be approved until the tentative plat is approved.

2-07.5.1.A.2 Label the section, township, and range; section corners; north arrow; and the scale;

PREVIOUS COMMENT 5: Until tentative plat DP17-0024 is approved the final plat cannot be approved.


If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and revised cover sheet of teh CC&R's
10/25/2017 LOREN MAKUS ENGINEERING REVIEW Approved
10/27/2017 KELLY LEE PIMA COUNTY WASTEWATER Needs Review
10/30/2017 KELLY LEE ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
10/30/2017 KELLY LEE UTILITIES TUCSON ELECTRIC POWER Reqs Change TEP does not approve the final plat for Camino Modern as submitted on September 28, 2017. Easements for TEP facilities must be shown on the final plat in order for us to approve.

Thank you,


Mary Burke
Right of Way Agent III
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com

Final Status

Task End Date Reviewer's Name Type of Review Description
11/03/2017 KROBLES1 OUT TO CUSTOMER Completed