Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S17-005
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S17-005
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2017 MMENDIB1 START PLANS SUBMITTED Completed
03/14/2017 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
240 N STONE AVENUE
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR

TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)



FROM: Janice Wagner
GIS Cartographer
Pima County Assessor's Office

DATE: March 13, 2017

RE: Assessor's Review and Comments Regarding:

MOUNTAIN VAIL ESTATES, PART B / S17-005 1ST REVIEW

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
03/20/2017 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Reqs Change Tucson Electric Power Co., (TEP) has reviewed the final plat submitted on March 13, 2017, and is unable to approve the plat at this time. An electrical design must be completed and TEP easements shown on the plat before TEP can approve. Please provide the signed letter approving the Equipment Placement that was emailed to Stantec on January 23, 2017, so that TEP may initiate the preliminary electrical design for the subdivision.



If you have any questions, please feel free to contact me at 520-917-8744.



Thanks,



Mary Burke

Right of Way Agent III

Tucson Electric Power Co.

Mail Stop HQE613

PO Box 711, Tucson, AZ 85702

Office - 520-917-8744

Cell - 520-401-9895

mburke@tep.com
03/20/2017 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Reqs Change See Comments in PRO: https://www.tucsonaz.gov/pro/pdsd/permitdetail/S17-005/30509004C

S17-005 Mountain Vail Estates Part I / 1st Submittal is being Returned for Corrections by Pima County Addressing.

Please let me know if you have any questions.

Thank you,



Robin Freiman

Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor
Tucson, AZ 85701

(520) 724-7570

Description: Description: cid:image001.png@01CE70DF.60625CC0
03/20/2017 AHINES2 UTILITIES SOUTHWEST GAS Passed Agency notified for information only.
03/24/2017 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: March 27, 2017
DUE DATE: April 10, 2017
SUBJECT: Final Plat
TO: Warren D. Thompson, PE
LOCATION: 11480 E Rincon Range Drive
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: S17-005
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per AM 2-07.5.4E show the required erosion hazard setback or add EHS into the description in the legend if it has the same alignment as the 100 year floodplain limits.
2) Per AM 2-07.5.4I show the detention/retention basins in a readily survey able manner.
3) Either side of lot one on sheet 3 has erroneous text that reads "label text" which should be removed.
4) Per AM 2-07.5.4C please label each common area individually that will have separate restrictions. There is some confusion where common area A (Landscape) is used to describe both wash area that is to be maintained as natural undisturbed open space and also some of the retention/detention basins adjacent to lots 48 and 49 and 54 and 55. The common area B is only shown on the basin north of lot 28 and at the South west corner of the site. It may appear the intention is to restrict two of the basins and other landscape areas labeled common area A as NUOS. It appears there should be some common area labels for the two basins and landscape areas that are labeled with separate letter designations from the natural wash. This could impact the format of the assurances.
5) Per AM 2-07.5.1H please update the S17-000 number to S17-005.
6) Per AM 2-07.5.4A identify the name of each street being created by this plat. There is a street on sheet 4 that does not have names yet.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.
04/04/2017 KLEE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved not in the Tucson Water availability area
04/04/2017 KLEE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved See Vail Water Company Assured Water Supply Letter in Sire/PRO.
04/05/2017 KLEE1 ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
04/05/2017 STEVE SHIELDS ZONING REVIEW Completed CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Mountain Vail Estates - Part I
Final Plat (1st Review)
S17-005

TRANSMITTAL DATE: March 22, 2017

DUE DATE: April 10, 2017

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS

1. 2-07.5.1.H Provide the final plat case number, S17-005, adjacent to the title block on all sheets.

1. 2-07.5.2.D General note 3 remove the reference to "C15-13-03" from the note as it is an annexation not a rezoning.

2. 2-07.5.2.J Provide a general note on the plan stating: "This subdivision is subject to Ordinance No.11130 which established zoning in the Mountain Vail Annexation Area".

3. Until development package DP16-0221 is approved the final plat cannot be approved.

Once the above comments are addressed Zoning is willing to provide an over the counter review. Call or email to schedule an appointment for this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
05/09/2017 KLEE1 PIMA COUNTY WASTEWATER Approved March 15, 2017


To: Warren Thompson, P.E.
Stantec Consulting Services Inc.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: _______________________________________________
Debbie Ketchem, Civil Engineer Assistant - Sr.
Development Liaison Unit
Subject: Approval Letter - sewer elements only
Final Plat - 1st Submittal, P17WS00018 (S17-005)


Pima County Regional Wastewater Reclamation Department (PCRWRD) hereby "Approves" Mountain Vail Estates - Part I, Lots 1 - 55 and Common Areas "A" - "C" as submitted on March 13, 2017. This approval is for elements related to the sewer system only.
Approval will need to be reobtained if the scope of the project changes that may impact the sewer. This also could include the language in the Dedication as well as easements for utilities/sewers. We request the applicant to contact RWRD-DLU to discuss what action if any shall be required. If the jurisdiction requires RWRD signature on the Mylar and there has been changes without communication it could delay the obtaining of RWRD's signature.

Do not hesitate to contact me if you have any questions at (520) 724-6481.

Cc: Lorenzo Hernandez, P.E., C.E. Manager, RWRD
Francisco Galindo, P.E., RWRD

Final Status

Task End Date Reviewer's Name Type of Review Description
05/08/2017 MMENDIB1 OUT TO CUSTOMER Completed