Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S15-061
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/04/2017 | ARUIZ1 | START | PLANS SUBMITTED | Completed | |
| 10/09/2017 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: City of Tucson Development Services FROM: Suzanne Gilpin GIS Cartographer Pima County Assessor's Office (520)724-4387 DATE: October 9, 2017 RE: Assessor's Review and Comments Regarding Final Plat- S15-061 SNAZZY SAX PROPERTIES FINAL PLAT * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. __X___ Plat does not meet Assessor's Office requirements. COMMENTS: " There must be a section tie, with a bearing and dimension from the section corner or quarter corner to the point of tie on the subdivision. " The perimeter line must be solid and the heaviest lineweight on the plat. The lot lines and common area lines must be solid and the next heaviest. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 10/26/2017 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Snazzy Sax Properties - 3656 E. Blacklidge Drive Final Plat (3rd Review) S15-061 TRANSMITTAL DATE: October 26, 2017 DUE DATE: November 01, 2017 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. This comment was not addressed. As the sequence number reference was removed from the upper right corner you now need to provide the sequence number reference in the both the upper and lower right corners outside the margin line. AM Section 2-07.5.1.D states "Place the words "SEQ#________" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation." 2-07.5.1.D Provide the "SEQ _________" along the bottom of the sheet in the lower right hand corner as shown on the redline. 2. This comment was not fully addressed. There are still walls, fences, water lines shown on the plat documents. 2-07.5.1.G The plat document should not show in development. i.e. building lines, setback lines etc. The plat should only show required property lines, easements, etc. As this site is already develop e a supplemental sheet that shows how the existing development meets code to the proposed property line will be required. See AM Sections 2-07.5.4 & 2-07.5.5 for required information on the plat. 3. This comment was not addressed correctly. The DDO number should be T16SA00332. 2-07.5.1.H As a Design Development Option (DDO) was required for this subdivision provide the DDO Case number adjacent to the title block on all sheets . See redline 4. Supplemental Sheet Comments. 5. Provide a separate supplemental development sheet. This sheet is separate from the plat sheets and should not be included in the number of sheets or the sheet index. This supplemental sheet should only contain one (1) sheet. This supplemental sheet should include all requirements for a residential plot plan. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 11/01/2017 | ALEXANDRA HINES | ZONING-RECORDATION | REVIEW | Completed | |
| 11/01/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | As previously commented, remove note 8 from the plat. |
| 11/01/2017 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/01/2019 | AMARTIN1 | OUT TO CUSTOMER | Completed |