Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S15-061
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2017 | PIBARRA1 | START | PLANS SUBMITTED | Completed | |
| 02/28/2017 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CITY OF TUCSON PLANNING & DEVELOPMENT SERVICES DEPARTMENT FROM: Suzanne Gilpin GIS Cartographer Pima County Assessor's Office (520)724-4387 DATE: February 28, 2017 RE: Assessor's Review and Comments Regarding Final Plat(2)- S15-061 SNAZZY SAX PROPERTIES * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. __X___ Plat does not meet Assessor's Office requirements. COMMENTS: " General notes must have the Basis of Bearing. " The perimeter line must be solid and heaviest line weight on the plat. The lot lines and common area lines must be solid and the next heaviest. " All adjacent subdivisions should be named, with map and plat in the appropriate areas around the subdivision. " Ownership should be labeled on signature lines with notary lines. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 03/07/2017 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Snazzy Sax Properties - 3656 E. Blacklidge Drive Final Plat (2nd Review) S15-061 TRANSMITTAL DATE: March 7, 2017 DUE DATE: March 24, 2017 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. 2-07.5.1.A.2 Label the section, township, and range; section corners; north arrow; and the scale on the location map. See redline. 2. 2-07.5.1.B If you are going to provide two (2) sheets for the final plat provide a sheet index on the first sheet. 3. . 4. 2-07.5.1.D Provide the "SEQ _________" along the bottom of the sheet in the lower right hand corner as shown on the redline. 5. 2-07.5.1.E.3 As this subdivision is a resubdivision of and existing plat the title block should reflect "A RESUBDIVISION OF THE EAST 65 FEET" as shown on the redline. 6. 2-07.5.1.F The plat should be oriented with the drawing with the north toward the top of the page. 7. 2-07.5.1.G The plat document should not show in development. i.e. building lines, setback lines etc. The plat should only show required property lines, easements, etc. As this site is already develop e a supplemental sheet that shows how the existing development meets code to the proposed property line will be required. See AM Sections 2-07.5.4 & 2-07.5.5 for required information on the plat. 8. 2-07.5.1.H Remove the S15-061 from outside the margin and provide it as shown on the redline. 9. 2-07.5.1.H As a Design Development Option (DDO) was required for this subdivision provide the DDO Case number adjacent to the title block on all sheets . See redline Supplemental Sheet Comments. 10. Provide a separate supplemental development sheet. This sheet is separate from the plat sheets and should not be included in the number of sheets or the sheet index. This supplemental sheet should only contain one (1) sheet. 11. Provide a lot coverage calculation for both proposed parcels on the supplemental sheet, see attached highlighted plot plan requirements sheet. Zoning acknowledges that some of these comments should have been made on the 1st review but unless corrected the plat will not be able to be recorded. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 03/08/2017 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | S15-061 Minor Subdivision/ 2nd Submittal is Approved by Pima County Addressing. Thank you, Robin Freiman Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 Description: Description: cid:image001.png@01CE70DF.60625CC0 |
| 03/21/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 03/21/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | 1. Revise the signature lines for the assurances paragraph. The line for PDSD Engineering Administrator needs to be changed to City Engineer. 2. A current title report is required when the plat is approved and forwarded to Mayor and Council for approval. All easements shown in the title report will need to be included on the plat. Note 8 should be removed. |
| 03/22/2017 | KLEE1 | ZONING-RECORDATION | REVIEW | Completed | |
| 03/22/2017 | KLEE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/06/2017 | MMENDIB1 | OUT TO CUSTOMER | Completed |