Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - FINAL PLAT - CONDO CONVERSION
Plan Number - S15-053
Review Name: RESUBMITTAL - FINAL PLAT - CONDO CONVERSION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2016 | KROBLES1 | START | PLANS SUBMITTED | Completed | |
| 01/11/2016 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: City of Tucson Planning and Development Services Department FROM: Suzanne Gilpin GIS Cartographer Pima County Assessor's Office (520)724-4387 DATE: January 12, 2016 RE: Assessor's Review and Comments Regarding Final Plat- CASA SETON S15-053 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. __X___ Plat does not meet Assessor's Office requirements. COMMENTS: " There must be a section tie, with a bearing and dimension from the Section corner or Quarter corner to the point of tie on the subdivision. " All adjacent subdivisions should be named, with map and plat in the appropriate areas around the subject subdivision. " A Deed from Potter Place LLC must be recorded to Title Security Agency as Trustee of Trust No. 201539S prior to recording Plat. |
| 01/12/2016 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 01/12/2016 | BVIESTE1 | PIMA COUNTY | WASTEWATER | Approved | REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 724-6500 DIRECTOR FAX: (520) 724-9365 January 12, 2016 To: Bob Tenor Bruce Brown, R.L.S. Engineering and Environmental Services Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: _______________________________________________ Debbie Ketchem, Civil Engineer Assistant - Sr. Development Liaison Unit Subject: Casa Seton, Lots 1-11 and Common Areas "A" & "B" Final Plat - 2nd Submittal, P15WS00045 (S15-053) Approval Letter Pima County Regional Wastewater Reclamation Department (PCRWRD) hereby "Approves" the above referenced submittal of the Final Plat submitted on January 8, 2016. Approval of the above referenced submittal does not authorize the construction of public or private sewer systems. Prior to the construction of such features, a Construction Authorization needs to be obtained from PDEQ. Approval will need to be reobtained if the scope of the project changes that may impact the sewer. This also could include the language in the Dedication as well as easements for utilities/sewers. We would request that you contact RWRD-DLU to discuss what action if any shall be required. If the jurisdiction requires RWRD signature on the Mylar and there has been changes without communication it could delay the obtaining of RWRD's signature. Do not hesitate to contact me if you have any questions at (520) 724-6481. Cc: Lorenzo Hernandez, P.E., C.E. Manager., RWRD Francisco Galindo, P.E., RWRD |
| 01/20/2016 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: CASA SETON FINAL PLAT S15-053 Tucson Electric Power Co., (TEP) has reviewed and approves the final plat for Casa Seton submitted on January 11, 2016. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. If you have any questions, please contact me at 520-917-8744. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQE613 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 02/08/2016 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Reqs Change | DATE: February 8, 2016 SUBJECT: Casas Seton Final Plat Engineering Re-submittal Review ADDRESS: 1777 N Potter Pl REVIEWER: Elizabeth Leibold P.E. ACTIVITY NUMBER: S15-053 SUMMARY: Engineering has reviewed the Final Plat submittal for Casa Seton Subdivision and has the remaining comments. PDSD Engineering does not recommend approval until the remaining comments are addressed. MASTER COVER SHEETS/ GENERAL NOTES: 1) Admin Man Sec.2-07.5.1.A: Clarify location of Wilson Wash more accurately on project-location map in the upper right corner of the first sheet of the plat. Wilson Wash is not straight - may use flood limits - see attached. 2) Admin Man Sec.2-07.5.3: For mylar submittal, all signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal. At mylar stage please assure ink used for seals, stamps, and signatures on mylar of final plat are permanent and non-smudge ink. 3) Admin Man Sec.2-07.5.3.C: If applicable, the following BENEFICIARY block must be included on the title page: BENEFICIARY "The beneficiary of (Title Company Name and Trust Number) is (Name and Address)." FINAL PLAT SURVEY RELATED COMMENTS: 4) UDC Sec.8.4.1.E.3, Admin Man Sec.2-07.5.4.A: Address the remaining easement comments: a) Label type of easement for keynote 1 on sheet 2; b) Clarify with blanket easement note or show on planview the following easements: i) electric/communications easement 20110820749 under Schedule B item G. ii) communications easement Bk72 pg 185 under Schedule B item J. iii) water easement Bk103 pg 273 under Schedule B item K. 5) UDC Sec.8.6.3.A, Admin Man Secs.2-07.5.1.I, 2-07.5.5: Address the remaining survey related comments: a) At least one corner of the subdivision will be tied by course and distance to a section corner, a quarter section corner, or an established city or county survey monument. The plat must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. b) Add symbol to planview and to legend for lot boundary survey monuments "to be set" (or have been set?). FINAL PLAT ASSURANCE COMMENTS: 6) Admin Man Sec.2-07.5.6.A&B: Revise CC&R's according to the remaining comments: a) Please renumber pages of the CC&R's so that every page including cover page and table of contents has a number and is sequential. Page numbering has been an issue in the past and is needed for page counting for fees, and can add delays to processing time if not corrected. b) Correct page number assignment in Table of Contents (For example, Maintenance is not on page 42.) c) Under Maintenance section in Article X, add information including maintenance of and liability for any proposed commonly-owned areas, and permanent administration by owners' association (private street and basin maintenance). d) A signed, dated, and notarized set of CC&R's will be needed at mylar stage of review at the latest. 7) UDC Sec.8.4.5.D.1.b: The final plat cannot be scheduled for Mayor and Council consideration until the original, notarized, signed assurances are reviewed and approved. a) UDC 8.6.2.B: Regarding proposed third party trust for the subdivision assurances, resubmit: i) original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST with the assurable items list; ii) original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST; iii) assure that all exhibits are attached, and the case number "S15-053" is at the top of the first page of the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST; iv) copy of the original Trust Agreement; v) Just for clarification, the copy of a sample Warranty Deed is no longer needed by this department nor City Attorney's Office nor Clerk's Office; vi) copy of the current Title Report. b) The 8½" by 11" location map sheet submitted with the revised assurance submittals that go to Mayor & Council is acceptable except that it needs the subdivision case number "S15-053" added to the page. For resubmittal, submit redlines, revised final plat sheets, CC&R's, assurances, comprehensive response letter addressing all comments, and title report. If you have any questions, do not hesitate to email me at elizabeth.leibold@tucsonaz.gov Elizabeth Leibold, P.E., CPM, CFM Civil Engineer City of Tucson (520) 837-4934 |
| 02/09/2016 | ARUIZ1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 2 rolled sets of the plans a disk containing all items submitted all items requested by review staff all items needed to approve the plan |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/10/2016 | KROBLES1 | OUT TO CUSTOMER | Completed |