Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S15-053
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/05/2015 | KROBLES1 | START | PLANS SUBMITTED | Completed | |
| 11/09/2015 | BVIESTE1 | UTILITIES | SOUTHWEST GAS | Approved | November 9, 2015 City of Tucson CDRC Attn: Patricia Gehlen, Manager 201 N. Stone Avenue Tucson, AZ 85701 RE: SWG Plan Review for Casa Seton - Final Plat CDRC: S15-053 Dear Ms. Gehlen: Southwest Gas Corporation (SWG) has no objection to the development of the above-mentioned project. Existing natural gas facilities are located in adjacent rights-of-way to the area of development and may be utilized for extension to the proposed development; specifically, an existing 2" gas main is located within the right-of-way of Elm Street Blue Stake and potholing are suggested for best accuracy when locating SWG facilities. Please be aware that SWG requires a minimum one-foot separation from distribution facilities and any proposed structures and two-foot separation from high pressure gas facilities. SWG requests the contractor use caution when working in the vicinity of gas facilities and protect and support gas facilities per Blue Stake requirements. SWG also requests that no trees be planted within close proximity to gas facilities due to root intrusion; therefore, SWG requires all tree placements have a minimum eight-foot clearance from the tree center line to existing or proposed gas facilities. Shrubs and bushes may be planted within the eight-foot clearance zone. All information is provided for reference use only. Please note that it is the responsibility of excavators or those developers planning excavation to verify actual field conditions in advance of construction so that requests for gas service or any potential issues can be addressed in a timely manner. Please include SWG in all future plat and development plan submittals of this project. If you have any questions or require any additional information, please contact me at (520) 794-6218 or TUCSWGDevReview@swgas.com. |
| 11/09/2015 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: City of Tucson Planning and Development Services Department FROM: Suzanne Gilpin GIS Cartographer Pima County Assessor's Office (520)724-4387 DATE: November 9, 2015 RE: Assessor's Review and Comments Regarding Final Plat- CASA SETON S15-053 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. __X___ Plat does not meet Assessor's Office requirements. COMMENTS: " There must be a section tie, with a bearing and dimension from the Section corner or Quarter corner to the point of tie on the subdivision. " All adjacent subdivisions should be named, with map and plat in the appropriate areas around the subject subdivision. |
| 11/10/2015 | BVIESTE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | See additional documents in PRO. We process this already for EEC, please see attached. Have a nice day, Kellie Anderson Tucson Water/New Development Administrative Assistant 520-837-2165 520-791-4718 520-791-2501 (fax) Kellie.Anderson@tucsonaz.gov |
| 11/10/2015 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | Final Plat approved by Pima County Addressing 11/09/15. (Please label project # S15-053 on all Sheets.) |
| 11/17/2015 | BVIESTE1 | PIMA COUNTY | WASTEWATER | Reqs Change | REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 724-6500 DIRECTOR FAX: (520) 724-9365 November 17, 2015 To: Bob Tenor Bruce Brown, R.L.S. Engineering and Environmental Services Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: ________________________________________________ Debbie Ketchem, Civil Engineer Assistant - Sr. Development Liaison Unit Subject: Casa Seton, Lots 1-11 and Common Areas "A" & "B" Final Plat - 1st Submittal, P15WS00045 (S15-053) Response Letter The Final Plat for the proposed project has been reviewed on behalf of Pima County Regional Wastewater Reclamation Department (PCRWRD). RWRD is requesting additional information for the above referenced submittal of the Final Plat as received on November 16, 2015. The following revisions are requested: 1. Final Plat must be signed by registered land surveyor before the Final Plat can be approved. 2. Sheet 1: General Note #3. Correct public street to "private" street. 3. The Tentative Plat (provided for reference) identifies the location of the existing private sewer different then what our records show in mapguide. Please verify the location and provide a pdf to RWRD if our records need to be corrected. See attached. The next submittal will be the second submittal for this Final Plat. The RWRD review fee for the second submittal will be $0.00 (Per PC Code, Title 13.20.030.A.2). Do not hesitate to contact me if you have any questions at (520) 724-6481. |
| 11/24/2015 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Casa Seton Final Plat (1st Review) S15-053 TRANSMITTAL DATE: November 25, 2015 DUE DATE: December 07, 2015 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS Section 2-07.1.0 APPLICABILITY 2-07.2.0 APPLICATION SUBMITTAL REQUIREMENTS 2-07.3.0 SUBMITTAL TIMING 2-07.4.0 FORMAT REQUIREMENTS 2-07.5.0 CONTENT REQUIREMENTS 2-07.6.0 APPROVAL DOCUMENTS AND PROCEDURE 2-07.1.0 APPLICABILITY Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013) 2-07.2.0 APPLICATION SUBMITTAL REQUIREMENTS Plat application packets are available from the PDSD Department. Completed applications and accompanying materials are submitted to the PDSD. Incomplete or inaccurate applications will not be accepted, nor will any application in which the pre-application conference or neighborhood meeting requirements have not been met. Should an incomplete submittal be accepted for review, the applicant should be aware that, because of a lack of information, the review will take longer since comments cannot be finalized until after the resubmittal when the required information is provided. The types of documents and the specific number of copies required of each of the documents are on the PDSD website or may be obtained from the CDRC office. The following documents and information shall be submitted upon application: 2.1 Application Form A completed application signed by the property owner or authorized designee; 2.2 Plat A plat must be prepared to the format and content requirements described herein; and, 2.3 Fees Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule. 2-07.3.0 SUBMITTAL TIMING Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat. 2-07.5.0 CONTENT REQUIREMENTS 5.1 General 2-07.5.1.H The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also. 1. COMMENT: Placed the subdivision case number, S15-053, in the lower right corner of the plat next to the title block on all sheets. 2-07.5.3 Standard Paragraphs The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal. 2-07.5.3.D Approval and Recording Data Blocks The APPROVAL paragraph, where the City Clerk certifies that the plat has been approved by Mayor and Council, and the RECORDING DATA paragraph, which provides space for the recording information, must be placed on the first sheet of the plat adjacent to each other. The paragraphs are as follows. 2. COMMENT: Revise the Approval and Recording Data Blocks to match what is shown under 2-07.5.3.D. APPROVAL "I, (fill in name of current City Clerk), Clerk of the City of Tucson, Arizona, hereby certify that this plat was approved by the Mayor and Council of the City of Tucson, Arizona, on this ____ day of __________, 20__." ____________________________________________ ______________ Clerk, City of Tucson Date Sequence________________ Fee_____________________ State of Arizona County of Pima I hereby certify that the instrument was filed for record at the request Of__________________________ Date________________________ Time_________________________ Witness my hand and Official Seal day and year above written. F. ANN RODRIGUEZ, County Recorder BY___________________________ Deputy 2-07.5.6 Protective Covenants Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will: 2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and 3. COMMENT: Provide a copy of the proposed CC&Rs with your next submittal. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat & proposed CC&Rs.. |
| 11/25/2015 | STEVE SHIELDS | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) 4 rolled sets of the plans 2) A disk containing all items submitted 3) All items requested by review staff 4) All items needed to approve this plan |
| 12/02/2015 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | SUBJECT: CASA SETON FINAL PLAT S15-053 Tucson Electric Power Co. (TEP) has reviewed the final plat for Casa Seton Final Plat submitted on November 6, 2015, and is unable to approve the plat at this time. A preliminary electrical design must be completed and easements for TEP facilities shown on the plat for TEP approval. If you have any questions, please contact me at 917-8744. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQE613 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 12/07/2015 | BVIESTE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Passed | |
| 12/07/2015 | BVIESTE1 | UTILITIES | CENTURYLINK | Passed | |
| 12/15/2015 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Reqs Change | DATE: December 15, 2015 SUBJECT: Casas Seton Final Plat Engineering Submittal Review ADDRESS: 1777 N Potter Pl REVIEWER: Elizabeth Leibold P.E. ACTIVITY NUMBER: S15-053 SUMMARY: Engineering has reviewed the Final Plat submittal for Casas Seton Subdivision and have the following comments. Review was delayed due to understaffing and employee sickness. Please see also redlines. PDSD Engineering does not recommend approval until the following comments are addressed. MASTER COVER SHEETS/ GENERAL NOTES: 1) Admin Man Sec.2-07.5.1.A: Clarify location of Wilson Wash more accurately on project-location map in the upper right corner of the first sheet of the plat. 2) Admin Man Sec.2-07.5.1.H: Add the subdivision case number (S15-053) in the lower right corner of each sheet of the final plat. Also provide old subdivision case numbers in the lower right corner of each sheet. 3) Add the following notes: a) Tech Man Sec.4-04.14.3.2: Add note to sheet 1: that the "Owner or Owners shall be solely responsible for operation, maintenance, and liability for drainage structures and detention basins; Owner or Owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and detention facilities at least once each year, and that these regular inspection reports will be on file with the Owner for review by City staff, upon written request; City staff may periodically inspect drainage and detention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and Owner or Owners agree to reimburse the City for any and all costs associated with maintaining drainage and detention facilities, should the City find the Owner or Owners deficient in their obligation to adequately operate and maintain their facilities. b) Admin Man Sec.2-07.5.2.C: Provide the following notes: i) "Total miles of new public streets are ____. ii) "Total miles of new private streets are ____." c) Admin Man Sec.2-07.5.2.I: Add note: "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." 4) Admin Man Sec.2-07.5.3: The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal. At mylar stage please assure ink used for seals, stamps, and signatures on mylar of final plat are permanent and non-smudge ink. 5) Admin Man Sec.2-07.5.3.D: Under the APPROVAL / RECODING DATA paragraphs, add missing Sequence number block: Sequence________________ Fee_____________________ State of Arizona County of Pima I hereby certify that the instrument was filed for record at the request Of__________________________ Date________________________ Time_________________________ Witness my hand and Official Seal day and year above written. F. ANN RODRIGUEZ, County Recorder BY___________________________ Deputy 6) Admin Man Sec.2-07.5.3.C: If applicable, the following BENEFICIARY block must be included on the title page: BENEFICIARY "The beneficiary of (Title Company Name and Trust Number) is (Name and Address)." 7) Admin Man Sec.2-07.5.3.B.4: Add the signature lines for the property owners. The number of signatures depends on the number of persons who have fee title interest according to a title report current within 30 days of recordation of the proposed plat. Make sure the property owners are correctly provided with beneficiary in Dedication sections on sheet 1. 8) Admin Man Sec.2-07.5.3.D: For the Approval and Recording Data Blocks on sheet 1, provide additional space for state seal / notary stamp). FINAL PLAT SURVEY RELATED COMMENTS: 9) UDC Sec.8.4.1.E.3, Admin Man Sec.2-07.5.4.A: Address the following easement comments: a) Assure that all easements are clearly drawn, labeled with Sequence Number, Book/page or Docket/page, and/or listed as a blanket easement, and/or labeled with accurate dimensions and bearings on the plat. b) Label type of easement for keynote 1 on sheet 2; c) Add / show / label on planview any utility easements (for electric). 10) Admin Man Sec.2-07.5.4: Provide the following information on the plat: a) A. Indicate leader lines for widths of street within the subdivision boundary being created by this plat. b) E. Show required setbacks, such as basin drainage setbacks; c) G. Lots 1 & 11 may be designated with a star symbol indicating location for access. d) H. Consider providing and showing no-vehicular access easement or no access easement along south project boundary; e) I. Label/show detention areas in a surveyable and readily retraceable manner. 11) Admin Man Sec.2-07.5.3: Provide Certification statement for civil engineer with expiration date of seal shall include certification of basin setbacks. 12) UDC Sec.8.6.3.A, Admin Man Secs.2-07.5.1.I, 2-07.5.5: Address the following survey related comments: a) At least one corner of the subdivision will be tied by course and distance to a section corner, a quarter section corner, or an established city or county survey monument. The plat must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. b) Describe all found boundary survey monuments on planview. c) Add symbol to planview and to legend for lot boundary survey monuments to be set (or have been set?). d) Add symbol to legend for Private Street survey monument. e) A one-half inch iron rod tagged by a registered land surveyor must be set at all lot corners upon completion of construction. Add "lot" to Note 1 on sheet 2. f) Consider adding a Note 3 to sheet 2 that states: All dimensions are measured (or calculated or recorded) unless other wise noted. Otherwise, clarify all boundary dimensions on planview as (M), (C), or (R). g) Add symbol to legend for "(C#)". Clarify where these curve numbers are located on plat since Reviewer was unable to find those curves identified on plat planview. FINAL PLAT ASSURANCE COMMENTS: 13) Admin Man Sec.2-07.5.6.A&B: Provide CC&R's for maintenance of and liability for any proposed commonly-owned areas, that includes the special situations requiring permanent administration by an owners' association (private street and basin maintenance). 14) UDC Sec.8.4.5.D.1.b: If any assurable improvement is not in place (common aea improvements and boundary survey monuments), assurances will be required. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are reviewed and approved. Address the following: a) If assurable items are intended to be constructed after plat, then the assurance documents must be submitted with subdivision descriptions on any page, including exhibit descriptions, matching the title block description on the first sheet of the plat. Please be aware that the legal office may reject assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block. b) UDC 8.6.2.B: Acceptable Forms of Assurances include: Completion/Performance Bond, Escrow Account, Letter of Credit, Third Party Land Trust, or an alternative forms of assurance acceptable to the PDSD Director and the City Attorney's Office in form and substance. (Personal checks are not accepted and Mayor and Council approval of the alternate assurance method, agreement, or form(s) is required prior to the approval of the final plat). If a third party trust is proposed for the subdivision assurances, address comments and resubmit: i) original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST with the assurable items list; ii) original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST; iii) assure that all exhibits are attached, and the case number "S15-053" is at the top of the first page of the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST; iv) copy of the original Trust Agreement; v) copy of a sample Warranty Deed; vi) copy of the current Title Report. c) The 8½" by 11" location map sheet submitted with the revised assurance submittals that go to Mayor & Council is acceptable except that it needs the subdivision case number added to the page. See redlines for additional comments. For resubmittal, submit redlines, revised final plat sheets, CC&R's, assurances, comprehensive response letter addressing all comments, and title report. If you have any questions, do not hesitate to call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/18/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |