Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S15-031
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2015 | KROBLES1 | START | PLANS BEING WALKED THRU | Completed | |
| 07/28/2015 | MICHAEL ST. PAUL | H/C SITE | REVIEW | Passed | |
| 07/28/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Reqs Change | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: S15-031 641 North 10th Avenue Lot Split with duplex on east lot and SFR on west lot TRANSMITTAL: August 5, 2015 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-3 zone (UDC 4.7.12). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6. The minimum setback is the greater of ten (10) feet, or three-fourth (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The proposed setback for the east parcel to the proposed west property line is three (3) feet, three (3) inches. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). The proposed setback for the deck additions to the front (north) property for the east parcel with the duplex is fifteen (15) feet, ten (10) inches. FROM: Michael St.Paul, Planning Technician PROJECT: S15-031 201 West 4th Street Lot Split with duplex on east lot and SFR on west lot TRANSMITTAL: August 5, 2015 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-3 zone (UDC 4.7.12). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6. The minimum setback is the greater of ten (10) feet, or three-fourth (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The proposed setbacks for the west parcel to the proposed east property line are five (5) feet, three (3), two (2) feet, three (3) inches, and one (1) foot at the chimney |
| 09/28/2015 | EGALLET1 | ZONING-RECORDATION | REVIEW | Completed | |
| 09/28/2015 | EGALLET1 | ENGINEERING | REVIEW | Needs Review | |
| 09/28/2015 | EGALLET1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 09/28/2015 | EGALLET1 | PLUMBING-COMMERCIAL | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/28/2015 | EGALLET1 | OUT TO CUSTOMER | Completed |