Plan Number: S14-056
Parcel: Unknown

Address:
2815 E 5TH ST

Review Status: Completed

Review Details: RESUBMITTAL - MINOR SUBD REVIEW

Plan Number - S14-056
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/11/2015 AROMERO4 START PLANS SUBMITTED Completed
02/18/2015 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)



FROM: Ada Griffin
GIS Cartographer
Pima County Assessor's Office


DATE: February 18, 2015


RE: Assessor's Review and Comments Regarding:

S14-056/THE CORNER AT 5TH AND TREAT - SECOND REVIEW FINAL PLAT

_

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.

COMMENTS:


" THANK YOU FOR YOUR SUBMITTAL



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
03/04/2015 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: The Corner at Fifth and Treat
Final Plat (2nd Review)
S14-056

TRANSMITTAL DATE: March 4, 2015

DUE DATE: March 12, 2015

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS

Section
2-07.1.0 APPLICABILITY
2-07.2.0 APPLICATION SUBMITTAL REQUIREMENTS
2-07.3.0 SUBMITTAL TIMING
2-07.4.0 FORMAT REQUIREMENTS
2-07.5.0 CONTENT REQUIREMENTS
2-07.6.0 APPROVAL DOCUMENTS AND PROCEDURE

2-07.1.0 APPLICABILITY

Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013)

2-07.2.0 APPLICATION SUBMITTAL REQUIREMENTS
Plat application packets are available from the PDSD Department. Completed applications and accompanying materials are submitted to the PDSD. Incomplete or inaccurate applications will not be accepted, nor will any application in which the pre-application conference or neighborhood meeting requirements have not been met. Should an incomplete submittal be accepted for review, the applicant should be aware that, because of a lack of information, the review will take longer since comments cannot be finalized until after the resubmittal when the required information is provided. The types of documents and the specific number of copies required of each of the documents are on the PDSD website or may be obtained from the CDRC office.

The following documents and information shall be submitted upon application:

2.1 Application Form
A completed application signed by the property owner or authorized designee;
2.2 Plat
A plat must be prepared to the format and content requirements described herein; and,
2.3 Fees
Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule.

2-07.3.0 SUBMITTAL TIMING
Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.

2-07.5.0 CONTENT REQUIREMENTS

5.1 General

2-07.5.1.A A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile and include the following information:

1. COMMENT: Remove the parcels from the location map as it is unreadable.

2-07.5.1.D Place the words "SEQ#________" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation.

2. COMMENT: Place the words "SEQ#________" in both the upper and lower right corners outside the margin line.

2-07.5.1.H The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

3. This comment was not addressed. COMMENT: Provide the subdivision case number, S14-056, adjacent to the title block on all sheets.

2-07.5.5.B Indicate tract boundary lines; right-of-way and centerlines of streets, easements, and other rights-of-way; and property lines of residential lots and other sites, with accurate dimensions, bearings, or deflection angles and radii, arcs, and central angles of all curves.

4. COMMENT: There is an access easement shown on lot 3, called out as "10' ACCESS EASEMENT DIDICATED T.E.P. BY FINAL PLAT". What does T.E.P mean or is this an access/utility easement?

5. COMMENT: The "10' ELECTRICAL EASEMENT DEDICATED TO T.E.P. BY FINAL PLAT" should be called out as a 10' electrical easement by final plat.

Additional Comments; Supplemental Sheet

6. This comment was not addressed. COMMENT: Show the proposed easements on the plan.

7. This comment was not addressed correctly. It does not appear that the vehicle use area is included in the lot coverage. COMMENT: Provide a lot coverage calculation for each lot on the plan.

8. Remove the cloud shown around "SEE DETAIL "A" " from the plan.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, three (3) copies of the revised supplemental sheet
03/04/2015 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: March 04, 2015
DUE DATE: March 12, 2015
SUBJECT: The Corner at Fifth and Treat Minor Subdivision Final Plat Submittal- 2nd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 2815 E 5th St
REVIEWER: Jason Green, CFM
ACTIVITY: S14-056


SUMMARY: Engineering Division of Planning and Development Services Department has received the proposed Final Plat and Title Report. Engineering Division has reviewed the submitted Final Plat and does not recommend approval at this time. Refer to this link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:

FINAL PLAT COMMENTS:

1) Complied.

2) Restated: AM Sec.2-07.5.1.H: Revise the Final Plat to place the assigned subdivision case number "S14-056" in the lower right corner of the plat next to the Title Block. The number could not be located on the final plat.

3) Complied.
4) Complied.
5) Complied.
6) Complied.
7) Complied.
8) Complied.
9) Complied.
10) Complied.
11) Complied.

NEW COMMENTS:

12) AM Sec.2-07.4.3: Revise the Final Plat to have a 2-inch margin on the left side and one-half inch margins on the remaining sides to comply with standardization requirements of state law for recorded plats.

13) AM Sec.2-07.5.1.D: Revise the Final Plat to place the words "SEQ#________" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation.

GENERAL COMMENTS:

Provide a revised Final Plat at re-submittal addressing the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For questions or to schedule a meeting I can be reached at 837-4929.

Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
03/05/2015 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) All items requested by review staff
3) All items needed to approve this plan
03/05/2015 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: THE CORNER OF 5TH AND TREAT FINAL PLAT
S14-056


Tucson Electric Power Co. (TEP) has reviewed and approves the final plat for The Corner of 5th and Treat. If you have any questions, please contact me at 917-8744.


Thank you,


Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
03/05/2015 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Reqs Change

Final Status

Task End Date Reviewer's Name Type of Review Description
03/17/2015 CPIERCE1 REJECT SHELF Completed