Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S14-052
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S14-052
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2015 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) 4 rolled sets of the plans
2) A folded set must also be submitted to RWRD
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve this plans
01/02/2015 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Reqs Change SUBJECT: FINAL PLAT - DESERT SQUARE SHOPPING CENTER
S14-052


Tucson Electric Power Co. (TEP) has reviewed the Final Plat for Desert Square Shopping Center submitted on November 26, 2014, and is unable to approve the plat at this time. The developer has requested that an electric easement that is identified on the plat be released (DKT. 4809/549, Item No. 12). TEP is in the process of releasing this easement. Once the easement has been released and the Quit Claim Deed recorded, the easement can be removed from the final plat.


Also, the subdivision in which the project is located needs to be identified in the title block of the plat.


If you have any questions, please feel free to contact me at 917-8744.


Thank you,


Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
11/26/2014 PGEHLEN1 START PLANS SUBMITTED Completed
12/01/2014 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved Regional Traffic Engineering has no comments on this submittal and supports its approval. Thank you.



Lawrence Bigelow, MBA, MSMC
Traffic Studies Analyst
1221 S. 2nd Avenue
Tucson, AZ 85713
Office: (520) 388-4228
Cell: (520) 310-6909
lbigelow@azdot.gov
12/01/2014 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Hello,

Parcels 13510150R, L, J, and Y already have service with Tucson Water and multiple meters are already in place.
Please let me know if you need further.

Thank you,



Kellie Anderson
Tucson Water
New Area Development
520-837-2165 (direct line)
520-791-4718 (division line)
520-791-2501 (fax)
Kellie.Anderson@tucsonaz.gov


>>> DSD_CDRC 11/26/2014 10:06 AM >>>

Dear Reviewers:


This is an electronic distribution for a CDRC Final Plat (Minor Subdivisoin) review. If you normally receive paper copies of the review documents, you will receive them soon.


The applicable case numbers are:


CDRC Development Plan: S14-052

Existing and Proposed Zoning:

Proposed Use: Existing Commercial Subdivision

Due Date: December 24, 2014

Electronic Documents may be found at the following link: http://www.tucsonaz.gov/PRO/Command?mode=permit&firstTime=true&number_key=s14-052&command=InitialProcess
12/03/2014 KAY MARKS PIMA COUNTY ADDRESSING Reqs Change 201 N. STONE AV, 1ST FL
TUCSON, AZ 85701-1207





MICHELENE NOWAKADDRESSING REVIEW
PH #: 724-9512


TO:
CITY PLANNING
FROM:
MICHELENE NOWAK, ADDRESSING REVIEW

SUBJECT:
S14-052 DESERT SQUARE SHOPPING CENTER FINAL PLAT-1ST REVIEW

DATE:
DECEMBER 2, 2014








The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


1.Lots need to be numbered consecutively - Lot 1, Lot 2, Lot 3, Lot 4, Lot 5 (Lot 2A , Lot 2B is not acceptable)2.Add complete legal description to Title Block: Desert Square Shopping Center Lots 1 thru 5 and Common Area A (PAAL) being a portion of Lot 19 in Block 15 of Manana Grande in Bk 13 of Maps & Plats at Pg 89, located in Section 20 . . . 3.Tax Parcel #135-10-150H –east of proposed Lot 5- will this parcel become a portion of proposed Lot 1? If so, please show correct property line on Final Plat



Note:
Lot 3 address: 7111 E. Golf Links Rd (Walgreens Store) existing building crosses property line into Lot 2 (And has 2 different owners)
Lot 4 address: 7191 E. Golf Links Rd (Wells Fargo Bank)
Lot 5 address: 7235 E. Golf Links Rd (Eegee’s) & 7245 E.Golf Links Rd (KFC)
12/05/2014 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved See documents in PRO
12/05/2014 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)



FROM: Julieann Arechederra
GIS Cartographer
Pima County Assessor's Office


DATE: December 5, 2014


RE: Assessor's Review and Comments Regarding Final Plat S14-052/Desert Square Shopping Center


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
____X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION.


" THERE MUST BE BEARINGS AND DIMENSIONS FOR THE PERIMETER AND ALL LOT LINES AND ALL COMMON AREAS. NE CORNER OF LOT 1 IS MISSING DISTANCE AND BEARINGS.

" ALL LOTS MUST BE NUMBERED AND HAVE SQUARE FOOTAGE. GENERAL NOTES HAS 5 LOTS, BOTTOM RIGHT CORNER SAYS LOTS 1 THRU 4 AND COMMON AREA A, AND THE DRAWING HAS LOT 1,3,4, & 2A,2B. MISSING LOT INFORMATION ON SE CORNER OF DRAWING.


" ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION.


NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
12/11/2014 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: December 11, 2014
DUE DATE: December 24, 2014
SUBJECT: Desert Square Shopping Center Block Final Plat Submittal- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 7109 E Golf Links Rd
REVIEWER: Jason Green, CFM
ACTIVITY: S14-052


SUMMARY: Engineering Division of Planning and Development Services Department has received the proposed Final Plat, Covenant Regarding Development and Use of Real Property and Title Reports (23OCT14, 26MAR14 and 10JUL14). Engineering Division has reviewed the submitted Final Plat and does not recommend approval at this time. Refer to this link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:

FINAL PLAT COMMENTS:

1) AM Sec.2-07.4.4: Revise the Final Plat to be drawn at a scale of no more than one inch equals 40-feet. Currently the plat sheet is drawn to one inch equals 60-feet. Or provide written approval from the CDRC Manager to use the proposed scale.

2) AM Sec.2-07.5.1.A.3: Revise the Final Plat and project location map to include the major watercourse (Pantano Wash) that cuts through the upper right hand corner of Section 20.

3) AM Sec.2-07.5.1.E.3: Revise the Final Plat and Title Block to indicate that the plat is a resubdivision of a previously recorded plat. Indicate the title and recordation information referencing the existing subdivision.

4) AM Sec.2-07.5.2.I: Revise the Final Plat to include the following note per the referenced standard; "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public."

5) AM Sec.2-07.5.3.A: Revise the Final Block Plat and Certification of Survey Section to read per the referenced section; "I hereby certify that the boundary survey as shown on this plat was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this plat was prepared under my direction."

6) AM Sec.2-07.5.3.B.1: Revise the Final Block Plat and Dedication Section (paragraph 1) to read per the referenced section; "We, the undersigned, hereby warrant that we are the owners and the only parties having any interest in the land shown on this plat, and we consent to the subdivision of said land in the manner shown hereon."

7) AM Sec.2-07.5.3.B.2.b: Revise the Final Block Plat and Dedication Section (paragraph 3) to include the reference to the Covenant Regarding Development and Use of Real Property SEQ#____. If the plat is utilizing a Common Area then it must be clearly defined in plan view with square footage or the cross access and parking agreement along with vehicular use area between all lots can be provided as language within the Covenant Regarding Development and Use of Real Property and a note added to the General Note Section reflecting as such.

8) AM Sec.2-07.5.3.B.3: Revise the Final Block Plat and Dedication Section (paragraph 4) to read per the referenced section; specifically change the word "flow" to "flood" at the end of the section.

9) AM Sec.2-07.5.3.B.4: Revise the Final Block Plat to include a notary section for the signature line of each property owner unless it can be assured that all 4 owners can sign the plat at the same time with one Notary.

10) AM Sec.2-07.5.3.D: Revise the Final Plat and Approval/Recording Data paragraphs to read per the referenced section;

"I, (fill in name of current City Clerk), Clerk of the City of Tucson, Arizona, hereby certify that this plat was approved by the Mayor and Council of the City of Tucson, Arizona, on this ____ day of __________, 20__."
_________________________ ______________
Clerk, City of Tucson Date

Sequence________________
Fee_____________________
State of Arizona
County of Pima
I hereby certify that the instrument
was filed for record at the request
Of__________________________
Date________________________
Time_________________________
Witness my hand and Official Seal
day and year above written.
F. ANN RODRIGUEZ, County Recorder
BY___________________________
Deputy

11) AM Sec.2-07.5.3.E: Revise the Final Plat and the Assurance Paragraph to read per the referenced section; "This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy."

12) AM Sec.2-07.5.4.A: Revise the Final Plat to indicate the width of the alley adjacent to the east and north east portion of the site. Label the roadways and alleys as Public or Private.

13) AM Sec.2-07.5.4.C: Revise the Final Plat to label Common Area "A" with a separate designation in plan view. Enclose with a solid line the common area in plan view or revise the (CRD&URP), if applicable, to provide language about cross access and cross parking along with the vehicular use area between all lots within the subdivision and add a General Note referencing the all-inclusive easement as per the (CRD&URP).

14) AM Sec.2-07.5.5.A: Revise the Final Plat so that at least one corner of the subdivision is tied by course and distance to a section corner, a quarter section corner or an established city or county survey monument. Corner tie recordation information is to be provided on the plat.

15) AM Sec.2-07.5.5.C.4.b: Revise the Final Plat so that all corners have a one-half inch iron rod tagged by a registered land surveyor. Per plan view the northwest corner of Lot 2A is missing either the set or found survey monument, revise.

16) AM Sec.2-07.5.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between all monuments were measured or calculated for all property line boundary information. This can be labeled in plan view are as a note within the General Note Section or Legend.

17) AM Sec.2-07.5.6: Revise the Covenant Regarding Development and Use of Real Property (CRD&URP) to add the assigned subdivision case number to Section B.

18) AM Sec.2-07.5.6: Revise the (CRD&URP) to use the correct legal document that references the new Unified Development Code in Section C. This form references the old Land Use Code which is no longer applicable.

19) AM Sec.2-07.5.6: Revise the (CRD&URP), if applicable, to provide language about cross access and cross parking along with the vehicular use area between all lots within the subdivision. As stated in the comment above either the plat needs to clearly define the limits of Common Area "A" in plan view or the plat needs to be revised to provide a reference to the CRD&URP in a General Note to allow all inclusive cross access and parking.

20) AM Sec.2-07.5.6: Revise the (CRD&URP) to provide an original signed, sealed and notarized copy for Final Block Plat approval.

21) AM Sec.2-07.6.1.E: Submit two copies of the updated title reports (current within 30 days) at Mylar submittal. A statement from the title company certifying the title reports previously submitted is still valid is acceptable in place of an additional title report. The Title Reports submitted have an effective dates of 23OCT14, 26MAR14 and 10JUL14 which do not meet the 30 day requirement.

GENERAL COMMENTS:

Provide a revised Final Plat and Title Report at re-submittal addressing the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For questions or to schedule a meeting I can be reached at 837-4929.

Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
12/12/2014 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Desert Square Shopping Center
Final Plat (1st Review)
S14-052

TRANSMITTAL DATE: December 16, 2014

DUE DATE: December 26, 2014

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS

Section
2-07.1.0 APPLICABILITY
2-07.2.0 APPLICATION SUBMITTAL REQUIREMENTS
2-07.3.0 SUBMITTAL TIMING
2-07.4.0 FORMAT REQUIREMENTS
2-07.5.0 CONTENT REQUIREMENTS
2-07.6.0 APPROVAL DOCUMENTS AND PROCEDURE

2-07.1.0 APPLICABILITY

Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013)

2-07.2.0 APPLICATION SUBMITTAL REQUIREMENTS
Plat application packets are available from the PDSD Department. Completed applications and accompanying materials are submitted to the PDSD. Incomplete or inaccurate applications will not be accepted, nor will any application in which the pre-application conference or neighborhood meeting requirements have not been met. Should an incomplete submittal be accepted for review, the applicant should be aware that, because of a lack of information, the review will take longer since comments cannot be finalized until after the resubmittal when the required information is provided. The types of documents and the specific number of copies required of each of the documents are on the PDSD website or may be obtained from the CDRC office.

The following documents and information shall be submitted upon application:

2.1 Application Form
A completed application signed by the property owner or authorized designee;
2.2 Plat
A plat must be prepared to the format and content requirements described herein; and,
2.3 Fees
Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule.

2-07.3.0 SUBMITTAL TIMING
Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.

2-07.4.0 FORMAT REQUIREMENTS
Plats must:
4.4 Be drawn to a scale of no more than one inch equals 40 feet; and,

1. COMMENT: The proposed scale does not meet this requirement.

2-07.5.0 CONTENT REQUIREMENTS

5.1 General

2-07.5.1.A A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile and include the following information:

2-07.5.1.A.1 The project site approximately centered within a one square mile area;

2. COMMENT: Show the project site centered within the one square mile area.

2-07.5.1.A.3 Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and,

3. COMMENT: Label the subdivisions on the location map.

2-07.5.1.E Provide a title block in the lower right corner of each sheet with the following information:

2-07.5.1.E.1 Subdivision name; number of blocks, lots, and/or units; and common area;

4. COMMENT:

2-07.5.1.E.3 If the final plat is a resubdivision of a previously recorded plat, indicate the title and the book and page/sequence number reference of the existing subdivision.

5. COMMENT: As this is a resubdivision of an existing plat provide the required info.

2-07.5.1.H The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

6. COMMENT: Provide the subdivision case number, S14-052, adjacent to the title block.

2-07.5.2 General Notes
The plat must include the following general notes. Additional notes specific to each project are required when pertinent. Fill in the blanks with the project-specific information.

2-07.5.2.B "The total number of lots is ____."

7. COMMENT: General note 2 states the total number of lots is 5 but it appears that there are 6, clarify.


2-07.5.3 Standard Paragraphs
The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal.

2-07.5.3.D Approval and Recording Data Blocks
The APPROVAL paragraph, where the City Clerk certifies that the plat has been approved by Mayor and Council, and the RECORDING DATA paragraph, which provides space for the recording information, must be placed on the first sheet of the plat adjacent to each other. The paragraphs are as follows.

8. COMMENT: Revise the Final Plat and Approval/Recording Data paragraphs to read per this section.

APPROVAL

"I, (fill in name of current City Clerk), Clerk of the City of Tucson, Arizona, hereby certify that this plat was approved by the Mayor and Council of the City of Tucson, Arizona, on this ____ day of __________, 20__."

____________________________________________ ______________
Clerk, City of Tucson Date

Sequence________________
Fee_____________________
State of Arizona
County of Pima
I hereby certify that the instrument
was filed for record at the request
Of__________________________
Date________________________
Time_________________________
Witness my hand and Official Seal
day and year above written.
F. ANN RODRIGUEZ, County Recorder
BY___________________________
Deputy


2-07.5.3.E Assurances
The following ASSURANCE block must be placed on the plat's first sheet.
9. COMMENT: Revise the Assurance block to read per this section.


ASSURANCES

"This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy."


City of Tucson Planning and Development Services Department Director


City of Tucson PDSD Engineering Administrator

2-07.5.4 Proposed Subdivision Information
Provide the following information on the plat:

2-07.5.4.B. Identify each block or lot within the subdivision boundary by number, and include the square footage of each;

10. COMMENT:

2-07.5.4.C. If the project has common areas, label each common area individually with a separate letter designation. Enclose with a solid line each common area, private street, etc., that will have separate restrictions, a separate homeowners' association, or any common area that is separated by a public right-of-way;

11. COMMENT: Show the proposed common area "A" on the plat as required above.

2-07.5.6 Protective Covenants

Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will:
2-07.5.6.A. Provide for maintenance of and liability for any proposed commonly-owned areas; and

12. COMMENT: As common areas are proposed some type of CC&R is required. The CC& R's should address at a minimum; cross access, cross parking, maintenance of common areas, etc. Provide a copy of the proposed CC&R's with your next submittal.

13. COMMENT: As buildings are proposed across property lines, Walgreens over lot 2B, a recorded covenant Regarding Development and Use of Real Property, see attached, must be recorded. Provided a copy of the recorded document with your next submittal. The provided covenant references the LUC and is not correct.

Additional Comments;

14. COMMENT: Remove the reference to "PERMITTING NOTES" as the notes shown under permitting notes should be under General Notes.

15. COMMENT: There is an electrical easement that runs across the north side of lot 2B, as this easement runs under the existing Walgreens it will need to be abandoned prior to approval of this plat. Show the easement as to be abandoned per sequence number ## on the plat.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
12/15/2014 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
12/16/2014 RONALD BROWN ZONING HC REVIEW Approved
12/18/2014 JIM EGAN COT NON-DSD FIRE Approved
12/22/2014 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Approved See documents in PRO
12/23/2014 JOE LINVILLE LANDSCAPE REVIEW Reqs Change Revise as requested by other agencies.
12/23/2014 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved
12/23/2014 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Completed
12/23/2014 PGEHLEN1 COT NON-DSD TUCSON POLICE DEPARTMENT Approved I have no issues with this proposal.



>>> DSD_CDRC 11/26/2014 10:06 AM >>>

Dear Reviewers:


This is an electronic distribution for a CDRC Final Plat (Minor Subdivisoin) review. If you normally receive paper copies of the review documents, you will receive them soon.


The applicable case numbers are:


CDRC Development Plan: S14-052

Existing and Proposed Zoning:

Proposed Use: Existing Commercial Subdivision

Due Date: December 24, 2014

Electronic Documents may be found at the following link: http://www.
12/24/2014 PGEHLEN1 ENV SVCS REVIEW Approved The Final Plat has been reviewed on behalf of Environmental Services and is approved. If there are any questions, I can be reached at kperry@perryengineering.net
12/24/2014 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
12/24/2014 PGEHLEN1 UTILITIES CENTURYLINK Passed
12/24/2014 PGEHLEN1 OTHER AGENCIES U. S. POST OFFICE Passed
12/24/2014 PGEHLEN1 UTILITIES EL PASO NATURAL GAS Passed
12/24/2014 PGEHLEN1 PIMA COUNTY WASTEWATER Reqs Change REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 724-6500
DIRECTOR FAX: (520) 724-9365


December 26, 2014


To: Rene Pina, P.E.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department
From: Francisco Galindo, P.E.
Civil Engineer, Development Liaison Unit
Subject: Desert Square Shopping Center, Lot 1, 2A, 2B, 3 & 4
Final Plat - 1st Submittal, S14-052, Review Comment Letter


The Final Plat for the proposed project has been reviewed on behalf of Pima County Regional Wastewater Reclamation Department (PCRWRD).
RWRD is requesting additional information for the above referenced submittal of the Final Plat as received on December 26, 2014. The following revisions are requested:
1. Please verify the ownership of the parcels. The owner "Sierra Industrial Park Delaware, LLC" was not identified as an owner per Pima County Assessor's records. Provide current information regarding ownership.
2. Define the Boundary of the proposed subdivision. The line type shall be darker than the surrounding parcels. Correct appropriately.
3. In the Title Block correct reference to "Resubdivision of a portion of Mañana Grande, Lot 19, Block 15, Book 13 - Page 89.

4. Use minimum standard size for lettering. Correct appropriately.

5. In Legend, correct symbol for survey monument. Follow City of Tucson / Pima County 2003 Edition, Standard Detail #100.

6. Easements where existing sewer G-73-06 is located. Use unique line type to distinguish the various easements in that location and label respectively.


S14-052
Desert Square Shopping Center
Final Plat - 1st Review


7. Please clarify: Is there private sewer within the easement identified as "10' easement for electric"? If so, please show.

8. Show location of all private sewer easements within the boundary of the project.

9. Parcel East of lot 4, There is a 10' Public Utility Easement; Dkt. 3617/419 Item 8 shown. Provide a copy of document with the next submittal (I was unable to obtain a copy of the easement with the docket number provided above).

The next submittal will be the second submittal for this Final Plat. The RWRD review fee for the second submittal will be $50.00 (Per PC Code, Title 13.20.030.A.2). Do not hesitate to contact me at (520) 724-6733 if you have any questions.
Do not hesitate to contact me if you have any questions at (520) 724-6733.




Francisco Galindo, P.E. Civil Engineer
Development Liaison Unit


Cc: Lorenzo Hernandez, P.E., C.E. Manager., RWRD
Chad Amateau, P.E., RWRD
Debbie Ketchem, RWRD
Project file
12/24/2014 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
01/05/2015 CPIERCE1 REJECT SHELF Completed