Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S14-049
Parcel: Unknown

Address:
6105 E PIMA ST

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S14-049
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/28/2014 AROMERO4 START PLANS SUBMITTED Completed
10/30/2014 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Letter received for Tentative plat approval is still valid
11/03/2014 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved See documents in PRO
11/03/2014 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson


FROM: Suzanne Gilpin
GIS Cartographer
Pima County Assessor's Office


DATE: 10/31/14


RE: Assessor's Review and Comments Regarding Final Plat-
S14-049 ALAMO CROSSING


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.


COMMENTS:



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
11/03/2014 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV, 1ST FL

TUCSON, AZ 85701-1207







MICHELENE NOWAK
ADDRESSING REVIEW

PH #: 721-9512







TO:
CITY PLANNING
FROM:
MICHELENE NOWAK, ADDRESSING REVIEW

SUBJECT:
S14-049 ALAMO CROSSING LOTS 1—18-FINAL PLAT/1ST REVIEW

DATE:
OCTOBER 31, 2014







The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



PLEASE LABEL PROJECT# S14-049 ON ALL SHEETS.





1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Final Plat to City Planning



***PIMA COUNTY ADDRESSING MUST RECEIVE A COPY OF THE RECORDED FINAL PLAT PRIOR TO THE ASSIGNMENT OF ANY ADDRESSES. PLEASE COORDINATE THE DELIVERY AND RECORDATION OF THE MYLAR WITH THE CITY OF TUCSON PLANNING***



2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.





***The Pima County Addressing Section can use digital CAD drawing files.

These CAD files can be e-mailed to: CADsubmittals@pima.gov

The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.***
11/06/2014 PGEHLEN1 PIMA COUNTY WASTEWATER Reqs Change REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 724-6500
DIRECTOR FAX: (520) 724-9365

November 6, 2014

To: Dan Castro, P.E.
Rick Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department
From: Francisco Galindo, P.E.
Civil Engineer, Development Liaison Unit
Subject: Alamo Crossing, Lots 1-18, Common Areas "A", "B-1" and "B-2"
Final Plat - 1st Submittal, S14-049, Request for Additional Information Letter


Pima County Regional Wastewater Reclamation Department (PCRWRD) hereby Request for Additional Information for the above referenced submittal of the Final Plat received on October 30, 2014:
1. All sheets, add project number S14-049 in lower right hand corner.
2. Sheet 1, in dedication, paragraph four, third line:
Delete "are granted" and replace with "irrevocably grants".
The revised sheets may be submitted electronically to Francisco.Galindo@pima.gov or to Debbie.Ketchem@pima.gov, no fee required. After RWRD's review and acceptance of the revised sheets, an Approval Letter will be sent.
Approval of the above referenced submittal does not authorize the construction of public or private sewer systems. Prior to the construction of such features, a Construction Authorization needs to be obtained from PDEQ.

Please contact me at 724-6733 if you have any questions.



Francisco Galindo, P.E., Civil Engineer
Development Liaison Unit

Cc: Lorenzo Hernandez, P.E., C.E. Manager., RWRD
Chad Amateau, P.E., RWRD
Debbie Ketchem, RWRD
Project file:
11/10/2014 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Alamo Crossing
Development Package (1st Review)
S14-049

TRANSMITTAL DATE: November 11, 2014

DUE DATE: November 26, 2014

The Zoning Review Section conditionally approves the final plat for this project subject to the following conditions.

1. COMMENT: The tentative plat must be approved.

2-07.5.1.H The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

2. COMMENT: Provide the subdivision case number, S14-049, in the lower right corner of the plat next to the title block.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
11/14/2014 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: November 14, 2014
SUBJECT: Alamo Crossing Final Plat- Engineering Review
TO: Zach Hinman
LOCATION: 6105 E Pima St; T14S R14E Sec01
REVIEWERS: Jason Green, CFM
ACTIVITY: S14-049

SUMMARY: Engineering Division of Planning and Development Services Department has received the proposed Final Plat, Title Report and Draft CC&Rs. Engineering Division has reviewed the submitted Final Plat and does not recommend approval at this time. Refer to this link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:

FINAL PLAT COMMENTS:

1) AM Sec.2-07.5.1.B: Revise the Final Plat to include a Sheet Index on the first sheet. Per the referenced section if the plat contains more than 1 sheet, a sheet index should be included representing what is on each sheet.

2) AM Sec.2-07.5.1.H: Revise the Final Plat to place the assigned subdivision case number "S14-049" in the lower right corner of the plat next to the Title Block.

3) AM Sec.2-07.5.3.B.2.c: Revise the Final Plat to read per the referenced section. Specifically the wording "public sewers" must be added to the last sentence of the paragraph.

4) AM Sec.2-07.5.3.E: Revise the Final Plat and the Assurance Paragraph to read per the referenced section; "This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy."

5) AM Sec.2-07.5.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between monuments were measured or calculated for all property line boundary information. This can be labeled in plan view are as a note within the General Note Section.

6) AM Sec.2-07.5.6: Revise the CC&Rs to accurately describe the property per the Title Block on the Final Plat, specifically describe the Common Areas in the first paragraph of the CC&Rs to match the Title Block with exact wording.

7) AM Sec.2-07.5.6: Revise the CC&Rs and Article 8 to include specific language for the required maintenance responsibility of the retention basins and associated drainage infrastructure.

8) AM Sec.2-07.5.6: Revise the CC&Rs to verify all spelling within the CC&Rs. One specific typographical error was found in Section 5.13, sentence 2.

9) AM Sec.2-07.5.6: A signed and original notarized copy of the CC&Rs will be required prior to Final Plat Mylar approval.

10) AM Sec.2-07.6.1.B: The final plat cannot be scheduled for Mayor and Council consideration until either Financial Assurances are submitted or a copy of a performance bond for the project is submitted. The final plat cannot be scheduled for Mayor and Council consideration until Financial Assurances are submitted and approved.

11) AM Sec.2-07.6.1.E: Submit two copies of an updated title report (current within 30 days) at Mylar submittal. A statement from the title company certifying the title report previously submitted is still valid is acceptable in place of an additional title report. The Title Report submitted has an effective date of May 09, 2014 which does not meet the 30 day requirement.

GENERAL COMMENTS:

Provide a revised Final Plat, CC&Rs, Title Report, and Assurances at re-submittal addressing the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For questions or to schedule a meeting I can be reached at 837-4929.

Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
11/21/2014 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed
11/21/2014 PGEHLEN1 UTILITIES CENTURYLINK Passed 1
11/21/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required.
Please resubmit the following items:

1) Two rolled sets of the plans
2) A disk containing all items submitted
3) All items requested by review staff
4) All items needed to approve this plan
11/21/2014 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: ALAMO CROSSING FINAL PLAT
S14-049


Tucson Electric Power Co. (TEP) has reviewed and approves the final plat submitted for review on October 30, 2014.
Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission.


If you have any questions, please feel free to contact me at 917-8744.




Thank you,


Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com