Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S14-042
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/22/2015 | CPIERCE1 | START | PLANS SUBMITTED | Completed | |
| 06/04/2015 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S14-042 10495 S Millicent Trail Final Plat - The Vistas at Rincon Knoll Lots 1-160 Block one, and Common Areas A - E, A re- subdivision of M/P BK 64, Page 6,7,8,9 Phases 1,2,3,4 . TRANSMITTAL DATE: June 4, 2015 DUE DATE: June 22, 2015 COMMENTS: Conditional Approval pending final comment is addressed and approval of the revised tentative plat. 1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site Final Plat that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A Final Plat application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 9, 2015. COMMENT The text for the building setback on sheet 6 next to lot 20 was not removed. Remove the text as required. 1. Follow-up to previous comment 6: The note for the building setbacks on sheet 3 adjacent to lots 1 -4 was not revised correctly, and the note on sheet 6 adjacent to lots 14 - 28 was not revised correctly. (***Typically the building setbacks are noted on the tentative plat and not the final plat. It would be best to remove the building setbacks from the final plat document but if you decide to keep them on the plan they need to be corrected as per the previous comment.) 2-07.5.4. E - Show required setbacks, such as erosion hazard, drainage, etc.; PREVIOUS COMMENT 06: Revise the annotation for the setback noted as 10 feet to state the greatest of 10' or ¾ the height on all sheets where noted. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 06/11/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 06/19/2015 | PGEHLEN1 | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: THE VISTAS AT RINCON KNOLLS FINAL PLAT S14-042 Tucson Electric Power Co. has reviewed and approved the final plat for The Vistas at Rincon Knolls submitted on May 27, 2015. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. If you have any questions, please contact me at 520-917-8744. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQW603 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 06/22/2015 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES June 22, 2015 Linda Thompson Subject: S14-042 RINCON KNOLLS Final Plat Dear Linda: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: 1 Executed Final Plat Double Matte Océ or Photo Mylar. 2 Title reports current within the last thirty (30) days. 1 Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with Consent to Dedicate and CC&R fees if applicable. Consent to Dedicate and CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page, if applicable. If the Consent to Dedicate is also a fixture filing, there is an additional $3 fee. If you are unsure of the fees, please call the County Recorders Office. 1 Original Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). 1 Copied Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). 1 CD with Digital Copy in PDF Format of Plat, CC&R's (if applicable) and Assurances (if applicable). 1 Check for balance owed City of Tucson for review ($149.93) Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval. Should you have any questions, please call me at (520) 837-4919 . Sincerely, Patricia Gehlen Project Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via Permits Plus |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/17/2015 | PGEHLEN1 | APPROVAL SHELF | Completed |
| 07/17/2015 | PGEHLEN1 | REJECT SHELF | Completed |
| 07/17/2015 | PGEHLEN1 | OUT TO CUSTOMER | Completed |