Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S14-042
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2014 | SPOWELL1 | START | PLANS SUBMITTED | Completed | |
| 09/09/2014 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Letter from Vail Water District valid through 2/16/2015 |
| 09/09/2014 | PGEHLEN1 | PIMA COUNTY | WASTEWATER | Reqs Change | REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 724-6500 DIRECTOR FAX: (520) 724-9365 September 17, 2014 To: Linda Thompson, Subdivision Coordinator The WLB Group, Inc. Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Francisco Galindo, P.E., Civil Engineer RWRD, Development Liaison Unit Subject: The Vistas at Rincon Knoll "Lots 1 thru 160, Block 1 and Common Areas "A" Thru "E" Final Plat - 1st Submittal, S14-042, Review Comments Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the Final Plat received on September 12, 2014. The plat is being "Returned for Additional Information". The following information is required for the next submittal: 1. Sheet 1 of 20. Add "Pima County" as a grantee to the 2nd paragraph of the Dedication 2. Sheet 3 of 20. The proposed Public Sewer Easement must be centered over the proposed public sewer as shown on the Sewer Improvement Plans. Please disregard the comment letter dated September 16, 2014, comment 2 was removed, and also disregard the comment letter dated September 17, 2014, it now refers to the new City's project number. The next submittal will be the second submittal for this Final Plat. The RWRD review fee for the second submittal will be $100.00 (Per PC Code, Title 13.20.030.A.2). Do not hesitate to contact me at (520) 724-6733 if you have any questions. Francisco Galindo, P.E. Civil Engineer, Development Liaison Unit Cc: Lorenzo Hernandez, P.E., RWRD Chad Amateau, P.E., RWRD Project file, DP13-0169, S14-042 |
| 09/09/2014 | PGEHLEN1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Passed | |
| 09/10/2014 | PGEHLEN1 | UTILITIES | SOUTHWEST GAS | Approved | See documents in PRO |
| 09/11/2014 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (Fax 520-791-5559) FROM: Suzanne Gilpin GIS Cartographer Pima County Assessor's Office DATE: September 11, 2014 RE: Assessor's Review and Comments Regarding Final Plat S14-042 - THE VISTAS AT RINCON KNOLLS * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. ___X___ Plat does not meet Assessor's Office requirements. COMMENTS: " The perimeter line must be solid and heaviest line weight on the plat. The lot lines and common area lines must be solid and the next heaviest. Lines for erosion setbacks, floodplain lines etc. should be the lightest line weight and be dashed or dot-dashed. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 09/17/2014 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S14-042 10495 S Millicent Trail Final Plat - The Vistas at Rincon Knoll Lots 1-160 Block one, and Common Areas A - E, A re- subdivision of M/P BK 64, Page 6,7,8,9 Phases 1,2,3,4 . TRANSMITTAL DATE: September 19, 2014 DUE DATE: October 7, 2014 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code and Development Standards were addressed. This plan has been reviewed for compliance with the Administrative Manual Standards listed in section 2-07 of the City of Tucson Administrative Manual. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC). The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. 1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site Final Plat that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A Final Plat application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is . SECTION 2-07: FINAL PLAT / MNOR SUBDIVISION Section 2-07.5.1.A - A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of three inches equals one mile and include the following information: 2-07.5.1.A.4 - The city's jurisdictional limits, if within the mapped area. 01. COMMENT: Draw and label the City of Tucson / Pima County jurisdictional limits on the location map. ********************************************************************* 2-07.5.1.H - The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also. 02. COMMENT: This project has been assigned the PDSD Subdivision Case number S14-042. List the case number in the lower right corner next to the title block of plan sheets. Also, list in the lower right corner of all plan sheets the following case numbers as reference, S06-125, T06SA00237, C9-06-07, and C15-04-02. ********************************************************************* 2-07.5.2.D - If the property is subject to conditions of rezoning, add the following note: "This plat is subject to the conditions of rezoning case number C9-__-__, unless superseded by a subsequent rezoning ordinance." 03. COMMENT: Add as a general note on sheet 1, the rezoning statement as noted in the standard above. (The rezoning case number is C9-06-07.) ********************************************************************* 2-07.5.2.F - If the property is subject to the requirements of the Hillside Development Zone, add the note: "Prior to the issuance of any building permits, Hillside Development Zone approval is required for Lots ____." 04. COMMENT: Add as a general note on sheet 1, the Hillside statement as noted in the standard above ********************************************************************* 2-07.5.3.D - Approval and Recording Data Blocks 05. COMMENT: On the cover sheet in the approvals text block, replace the City of Tucson clerk's name listed on the cover sheet with the current Clerk's name, "Roger Randolph". Revise the approval text block to comply with the current information listed in Administrative Manual section 2-07.5.3.D. ********************************************************************* 2-07.5.4. E - Show required setbacks, such as erosion hazard, drainage, etc.; 06. COMMENT: Revise the annotation for the setback noted as 10 feet to state the greatest of 10' or ¾ the height on all sheets where noted. ********************************************************************* 07. COMMENT: Provide a copy of the revised CC&R's in the next submittal. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and any requested documents. |
| 09/22/2014 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Reqs Change | 201 N. STONE AV, 1ST FL TUCSON, AZ 85701-1207 MICHELENE NOWAK ADDRESSING REVIEW PH #: 724-9512 TO: CITY PLANNING FROM: MICHELENE NOWAK, ADDRESSING REVIEW SUBJECT: S14-042 THE VISTAS AT RINCON KNOLLS LOTS 1-160 COMMON AREAS “A-E” /FINAL PLAT-1ST REVIEW DATE: SEPTEMBER 19, 2014 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Label Project# S14-042 on all Sheets On Sheet 2 correct tax parcel# above #305-06-003W and #305-72-2800 to: #205-90-004A Label Common Area “D” areas on map. Label Common Area “C” on map. Spell out Paige Canyon Lane, American Peak Drive, Alessi Peak Place, Pantano View Drive. Correct street sequence to Rincon Knolls Loop. On Sheet 3 label Common Area “D”. On Sheet 4 correct tax parcel# east of Common Area “D” (in Section 4-16-16E) to #305-06-003X. Tax parcel# east of Common Area “D” in Section 9-16-16E is #305-05-1250. On Sheet 5 correct tax parcel# east of Common Area “D” to #305-06-003X. On Sheet 8 correct tax parcel# east of Lot 145 to #305-06-003X. On Sheet 12 please correct the North Arrow. NOTE: When the plat of “The Vistas at Rincon Knolls” records all streets previously recorded lying within Block 1 will become null and void. d |
| 10/02/2014 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | SUBJECT: THE VISTAS AT RINCON KNOLLS S14-042 Tucson Electric Power Co. (TEP) has reviewed the final plat submitted on September 9, 2014. TEP is unable to approve the plat at this time. An electrical design must be completed and easements for our equipment must be shown on the plat prior to TEP approval. Please feel free to contact me at 917-8744 if you have any questions regarding this review. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQW603 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 10/07/2014 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | Revise general note 7 to match the administrative standard. Even block 1 will require council approval for platting. Clearly indicate the purpose for each of the common areas. Provide the subdivision number on each sheet. |
| 10/08/2014 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. The following items must be included in the resubmittal: 1) 4 rolled sets of the plans 2) A disk that includes all items submitted 3) All items requested by review staff 4) All items needed to approve this plan |
| 10/08/2014 | PGEHLEN1 | UTILITIES | CENTURYLINK | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/12/2014 | SHANAE POWELL | REJECT SHELF | Completed |