Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S14-024
Parcel: Unknown

Address:
3954 E HOLMES ST

Review Status: Completed

Review Details: RESUBMITTAL - MINOR SUBD REVIEW

Plan Number - S14-024
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2014 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/11/2014 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV, 1ST FL

TUCSON, AZ 85701-1207







MICHELENE NOWAK
ADDRESSING REVIEW

PH #: 721-9512







TO:
CITY PLANNING
FROM:
MICHELENE NOWAK, ADDRESSING REVIEW

SUBJECT:
3954 EAST HOLMES, LOTS 1 & 2/FINAL PLAT 1ST REVIEW

DATE:
AUGUST 11, 2014







The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.





1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Final Plat to City Planning



***PIMA COUNTY ADDRESSING MUST RECEIVE A COPY OF THE RECORDED FINAL PLAT PRIOR TO THE ASSIGNMENT OF ANY ADDRESSES. PLEASE COORDINATE THE DELIVERY AND RECORDATION OF THE MYLAR WITH THE CITY OF TUCSON PLANNING***



. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.





***The Pima County Addressing Section can use digital CAD drawing files.

These CAD files can be e-mailed to: CADsubmittals@pima.gov

The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.***
08/12/2014 LOREN MAKUS ENGINEERING REVIEW Approv-Cond The Engineering Section recommends approval of the minor subdivision plat on the following conditions:
1. Revise the supplemental site plan to provide for 5 foot sidewalks in the right-of-way. TSM 10-01.4.1.A.1.a
2. Revise the supplemental site plan to show the Sight Visibility Triangles for the street intersection. TSM 10-01.5.1 Note that SVTs are not required for the driveways.
3. Provide a complete estimate for the cost of all assurable items, including utility connections, sidewalks and driveways. Include a draft of the assurances documents for review.
Loren Makus
08/14/2014 STEVE SHIELDS ZONING REVIEW Approved
08/22/2014 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: 3954 E. HOLMES, LOTS 1 & 2

S14-024 – MINOR SUBDIVISION



Tucson Electric Power Co. (TEP) has reviewed and approves the Final Plat for 3954 E. Holmes, Lots 1 & 2. If you have any questions, please contact me at 917-8744.



Thank you,



Mary Burke

Right of Way Agent

Tucson Electric Power Co.

Mail Stop HQW603

PO Box 711, Tucson, AZ 85702

Office - 520-917-8744

Cell - 520-401-9895

mburke@tep.com
09/03/2014 RONALD BROWN ZONING HC REVIEW Approved
09/04/2014 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

September 4, 2014


Ken Perry

Subject: S14-024/ 3954 E HOLMES ST MINOR SUB Final Plat

Dear Ken:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

1 Executed Final Plat Double Matte Océ or Photo Mylar.

2 Title reports current within the last thirty (30) days.

1 Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with Consent to Dedicate and CC&R fees if applicable. Consent to Dedicate and CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page, if applicable. If the Consent to Dedicate is also a fixture filing, there is an additional $3 fee. If you are unsure of the fees, please call the County Recorders Office.

1 Original Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable).

1 Copied Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable).

1 CD with Digital Copy in PDF Format of Plat, CC&R's (if applicable) and Assurances (if applicable).

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Should you have any questions, please call me at (520) 837-4919.

Sincerely,

Patricia Gehlen
Project Manager


All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via Permits Plus
09/05/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond see letter above

Final Status

Task End Date Reviewer's Name Type of Review Description
09/22/2014 CPIERCE1 OUT TO CUSTOMER Completed