Review Status: Completed
Review Details: MINOR SUBDIVISION REVIEW
Plan Number - S14-024
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/06/2014 | AROMERO4 | START | PLANS SUBMITTED | Completed | |
| 06/09/2014 | PGEHLEN1 | PIMA COUNTY | WASTEWATER | Passed | Per form signed by L. Hernandez. |
| 06/10/2014 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | See letter in SIRE |
| 06/10/2014 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | Regional Traffic Engineering has no comments on this submittal and supports the Final Plat acceptance. Thank you. |
| 06/10/2014 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Susan King GIS Cartographer Pima County Assessor's Office DATE: June 10, 2014 RE: Assessor's Review and Comments Regarding Final Plat S14-024 3954 East Holmes * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 06/11/2014 | ROBERT SHERRY | PLUMBING-RESIDENTIAL | REVIEW | Approved | |
| 06/11/2014 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: 3954 E. Holmes Lots 1 & 2 Condominium Final Plat (1st Review) S14-024 TRANSMITTAL DATE: June 11, 2014 DUE DATE: July 07, 2014 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS 2-07.5.1.H The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also. 1. COMMENT: Place the subdivision case number, S14-024, in the lower right corner of the plat next to the title block. Additional Comments 2. COMMENT: Separate the supplemental site plan from the final plat. 3. COMMENT: Provide a lot coverage for Lot 1 on the supplemental site plan, see UDC Article 6.4.3 for requirements. 4. COMMENT: Remove the proposed residence from Lot 2 as this will required a separate plot plan when developed. 5. The supplemental site plan shows "SHEET 1 OF 2" in the lower right hand corner. Provide sheet 2 of 2 or change the sheet count. Once the above comments have been addressed Zoning is willing to provide and over the counter review. Call or email to schedule this appointment. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and supplemental sheet. |
| 06/13/2014 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 06/17/2014 | KAY MARKS | PIMA COUNTY | ADDRESSING | Reqs Change | 201 N. STONE AV, 1ST FL TUCSON, AZ 85701-1207 MICHELENE NOWAK ADDRESSING REVIEW PH #: 724-9512 TO: CITY PLANNING FROM: MICHELENE NOWAK, ADDRESSING REVIEW SUBJECT: 3954 EAST HOLMES, LOTS 1 & 2/ FINAL PLAT 1ST REVIEW DATE: JUNE 12, 2014 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1. Label project# S14-024 on all Sheets 2. On Title Block correct to: 3954 East Holmes, Lots 1 & 2 being a Re-Subdivision of a portion of Lot 1, Block 5, Country Club Heights . . . . . . |
| 06/25/2014 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | SUBJECT: 3954 E. HOLMES ST. – MINOR SUB S14-024 Tucson Electric Power Co. (TEP) has reviewed the Site Plan for 3954 E. Homes St. Minor Subdivision and is unable to approve the plat at this time. Please add a ten-foot wide TEP easement for the existing overhead facilities that are located adjacent and parallel to the southern property boundary. Permanent access to the facilities must be maintained at all times. Please feel free to contact me at 917-8744 with any questions. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQW603 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 06/25/2014 | RONALD BROWN | ZONING HC | REVIEW | Reqs Change | 1. All new residential dwelling developments are to comply with the Inclusive Home Design Ordinance #10463. Please provide a note of compliance to that effect on the drawings. |
| 06/26/2014 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | Drainage Statement 1. Revise the discussion of the all-weather-access requirements to address the provisions of the Standards Manual for Drainage Design and Floodplain Management. See Section 11.2 for the all-weather-access requirements. Supplemental Site Plan and Plat 2. Show how each lot receives utility service and provide easements as necessary. For example, the existing house receives its electrical service from the power pole at the southwest corner of the existing lot. Provide an easement for the power line. Also show where the water service will enter the property. Tucson Water requires the meter to be on the property receiving the service. 3. On the supplemental site plan, show new sidewalks. If sidewalks are not provided before the subdivision is approved, assurances will be required for the provision of sidewalks. Describe the assurance mechanism to be used. 4. In your response letter, provide a discussion of all required items in Administrative Manual 2-09.3.0. Indicate which items are complete and describe in detail. Indicate how each of the incomplete items will be completed or provided for in the assurances. 5. Check spelling and grammar in all notes on all sheets. Make sure the language of the dedication statement has agreement in number. |
| 06/27/2014 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Passed | |
| 06/27/2014 | PGEHLEN1 | UTILITIES | SOUTHWEST GAS | Approved | See documents in PRO |
| 06/30/2014 | PGEHLEN1 | COT NON-DSD | TUCSON POLICE DEPARTMENT | Approved | I have no issues with this request. |
| 07/01/2014 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 07/07/2014 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 07/07/2014 | JANE DUARTE | COT NON-DSD | PARKS & RECREATION | Approved | Patricia, Tucson Parks and Recreation does not have any planned or existing facilities affected by this subdivision. Please mark the Parks and Recreation review status as "approved". Thank you, Howard Howard B. Dutt, ASLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Fax: (520) 791-4008 Howard.Dutt@tucsonaz.gov |
| 07/08/2014 | PGEHLEN1 | UTILITIES | CENTURYLINK | Passed | |
| 07/08/2014 | PGEHLEN1 | OTHER AGENCIES | U. S. POST OFFICE | Passed | |
| 07/08/2014 | PGEHLEN1 | UTILITIES | EL PASO NATURAL GAS | Passed | |
| 07/08/2014 | ROBERT YOUNG | PIMA COUNTY | PIMA CTY - DEV REVIEW | Passed | |
| 07/08/2014 | PGEHLEN1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | see documents in PRO |
| 07/08/2014 | PGEHLEN1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Passed | |
| 07/09/2014 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) 4 rolled sets of the plans 2) A disk with all items submitted 3) All items requested by review staff 4) All items needed to approve this plan. |
| 07/09/2014 | PGEHLEN1 | ENV SVCS | REVIEW | Approved | Comments: ES approves of individual 95 gallon refuse and recycle containers for both lots 1 and 2. Lot 1 will receive curbside service off Holmes and lot 2 from Longfellow. No objections. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/08/2014 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |