Plan Number: S14-002
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - FINAL PLAT - CONDO CONVERSION

Plan Number - S14-002
Review Name: RESUBMITTAL - FINAL PLAT - CONDO CONVERSION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/22/2014 PGEHLEN1 START PLANS SUBMITTED Completed
01/24/2014 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved See Documents in SIRE
01/27/2014 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: January 27, 2014
SUBJECT: Plaza Central- Railyard Condominium Final Plat Submittal- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 345 E Congress St, T14S R13E Sec12 Ward 6
REVIEWER: Jason Green, CFM
ACTIVITY: S14-002

SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Final Plat, Condominium Declaration and Title Report. Engineering Division has reviewed the submitted Final Plat and does not recommend approval at this time. Refer to this link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:

FINAL PLAT COMMENTS:

1) AM Sec.2-07.5.1.H: Revise the Final Plat to place the assigned subdivision case number "S14-002" in the lower right corner of the plat next to the Title Block on all sheets.

2) AM Sec.2-07.5.3.D: Revise the Final Plat and Recording Data paragraph to read per the referenced section;

Sequence________________
Fee_____________________
State of Arizona
County of Pima
I hereby certify that the instrument
was filed for record at the request
Of__________________________
Date________________________
Time_________________________
Witness my hand and Official Seal
day and year above written.
F. ANN RODRIGUEZ, County Recorder
BY___________________________
Deputy

3) AM Sec.2-07.5.3.E: Revise the Final Plat and the Assurance Paragraph to read per the referenced section; "This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by a land trust financial assurance agreement, the posting of performance bonds, an escrow account, letter of credit, or other security as the City of Tucson deems necessary and proper. In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the city may suspend the issuance of building permits or certificates of occupancy."

4) AM Sec.2-07.5.6: Revise the Condominium Declaration (CD) to accurately describe the property per the Title Block on the Final Plat, specifically included and describe the Common Elements and Limited Common Elements in the first paragraph of the CD to match the Title Block with exact wording for all common/limited common elements.

5) AM Sec.2-07.5.6: A signed and original notarized copy of the CD will be required prior to Final Plat Mylar approval.

6) AM Sec.2-07.6.1.E: Submit two copies of an updated title report (current within 30 days). A statement from the title company certifying the title report (dated 06DEC13) previously submitted is still valid is acceptable in place of an additional title report.


GENERAL COMMENTS:

Provide a revised Final Plat, CC&R and Title Report at re-submittal addressing the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For questions or to schedule a meeting I can be reached at 837-4929.

Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
01/27/2014 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
01/27/2014 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Plaza Centro
Final Plat (1st Review)
S14-002

TRANSMITTAL DATE: January 28, 2014

DUE DATE: February 5, 2014

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

1. UDC Section 8.5.2.A, Final Plat Approval Period. A final plat shall be approved and recorded within three years of the tentative plat approval date. A final plat is subject only to the ordinances in effect at the time of the tentative plat application except where an ordinance specifically states that it applies to pending applications.

SECTION 2-07.0.0: FINAL PLAT, BLOCK PLAT, MINOR SUBDIVISION, AND CONDOMINIUM PLAT APPLICATIONS

2-07.5.1.H The S(Year)-___ subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also.

1. COMMENT: Place the subdivision case number, S14-002. in the lower right corner of the plat next to the title block.

2-07.5.3.D Approval and Recording Data Blocks. The APPROVAL paragraph, where the City Clerk certifies that the plat has been approved by Mayor and Council, and the RECORDING DATA paragraph, which provides space for the recording information, must be placed on the first sheet of the plat adjacent to each other. The paragraphs are as follows.

2. COMMENT: Review AM 2-07.5.3.D Approval and Recording Data Blocks and provide the correct approval and recording block.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
01/27/2014 RONALD BROWN ZONING HC REVIEW Approved
01/28/2014 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved See letter in SIRE.
01/28/2014 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: AMENDED CONDO FINAL PLAT - PLAZA CENTRO RAILYARD
S14-002

Tucson Electric Power Co. has reviewed the Amended Final Plat submitted on January 22, 104 and is unable to approve the plat at this time. Please add the following easement language to the Dedication:

"AN EASEMENT IS GRANTED TO TUCSON ELECTRIC POWER FOR THE PURPOSE OF ACCESS, INSTALLATION AND MAINTENANCE OF ELECTRICAL METERS CABLE AND CONDUITS THAT WILL BE GROUPED TOGETHER AND ATTACHED TO EXTERIOR WALLS." Upon addition of the above language, TEP can approve the Final Plat.

If you have any questions, please feel free to contact me at 917-8744.

Thank you,

Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com<mailto:mburke@tep.com>
01/31/2014 PGEHLEN1 PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV, 1ST FL
TUCSON, AZ 85701-1207

[Description: Pcseal]



MICHELENE NOWAK
ADDRESSING REVIEW
PH #: 721-9512


TO:

CITY PLANNING

FROM:

MICHELENE NOWAK, ADDRESSING REVIEW

SUBJECT:

S14-002 2ND AMENDMENT CONDOMINIUM FRINAL PLAT FOR PLAZA CENTRO-RAILYARD UNITS 1-12-1ST REVIEW OF FINAL PLAT

DATE:

January 31, 2014


The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

PLEASE PUT PROJECT# S14-002 ON ALL SHEETS.


1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Final Plat to City Planning.

***PIMA COUNTY ADDRESSING MUST RECEIVE A COPY OF THE RECORDED FINAL PLAT PRIOR TO THE ASSIGNMENT OF ANY ADDRESSES. PLEASE COORDINATE THE DELIVERY AND RECORDATION OF THE MYLAR WITH THE CITY OF TUCSON***

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.

***The Pima County Addressing Section can use digital CAD drawing files.
. These CAD files can be e-mailed to CADsubmittals@pima.gov<mailto:CADsubmittals@pima.gov> The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County's Geographic Information System. Your support is greatly appreciated.***
02/03/2014 KBROUIL1 COT NON-DSD FIRE Approved .
02/03/2014 ED ABRIGO PIMA COUNTY ASSESSOR Denied Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)


FROM: Julieann Arechederra
GIS Cartographer
Pima County Assessor's Office


DATE: January 31, 2014


RE: Assessor's Review and Comments Regarding:
S14-002 PLAZA CENTRO AMENDED CONDO


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
____X___ Plat does not meet Assessor's Office requirements.

COMMENTS:



" THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION.


" CHECK OWNERSHIP TO MAKE SURE IT MATCHES WHAT WE HAVE. OUR RECORDS SHOW OWNERSHIP FOR UNITS 6-10 TO BE TUCSON PROPERTIES I LLC.



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
02/06/2014 PGEHLEN1 UTILITIES CENTURYLINK Passed
02/06/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) 4 rolled sets of the plans
2) A disk containing all items submitted
3) All items requested by review staff
4) All items needed to approve these plans
02/06/2014 PGEHLEN1 PIMA COUNTY WASTEWATER Approved REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 724-6500
DIRECTOR FAX: (520) 724-9365

February 5, 2014


To: Marty Magelli, P.E., Project Manager
Baker & Associates Engineering, LLC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Francisco Galindo, P.E., Civil Engineer
Planning and Engineering - DLU

Subject: 2nd Amended Condominium Final Plat
Final Plat - 1st Submittal, S14-002, Review Comments

The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department.
PCRWRD hereby approves the above referenced submittal of the Final Plat received by us on January 22, 2014.
Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) will need to be obtained. Cypress Civil Development indicated that the development will not include any public sewers.

If you have any questions regarding the above comments, please contact me.




Francisco Galindo, P.E.
Planning and Engineering - Development Liaison Unit


Cc: Chad Amateau, P.E., RWRD
Lorenzo Hernandez, P.E., RWRD
Project file
02/06/2014 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
02/11/2014 CPIERCE1 REJECT SHELF Completed
02/11/2014 SHANAE POWELL OUT TO CUSTOMER Completed