Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S13-030
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/27/2013 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/27/2013 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Passed | Approved on previous review. |
| 09/30/2013 | MICHAEL ST. PAUL | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: Michael St Paul Planning Technician PROJECT: S13-030 4030 East 22nd Street Block Plat TRANSMITTAL: September 30, 2013 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Unified Development Code (Section 8.4.1) and the Administrative Manual (Section 2-07) were addressed. Zoning conditionally approves the final plat sheets subject to adding the correct PDSD activity case number. The assigned PDSD Case number was provided incorrectly on the last review. The assigned case number is S13-030. Replace the case number S13-025 with S13-030 in the lower right corner of the final plat sheets. Previous Comment: Provide the subdivision case number (S13-025) in the lower right corner of each sheet of the final plat (AM 2-07.5.1.H). Additional comments may be necessary relative to additional information provided with subsequent submittals. |
| 10/01/2013 | CHRIS POIRIER | PIMA COUNTY | ADDRESSING | Approv-Cond | Per last comments |
| 10/01/2013 | PGEHLEN1 | UTILITIES | SOUTHWEST GAS | Approv-Cond | Informational conditions only. |
| 10/11/2013 | JOE LINVILLE | LANDSCAPE | REVIEW | Reqs Change | 1) TSM 4-02.2.4 Identification of Regulated Areas and Protected Riparian Areas All tentative plats, site plans, plot plans or other plans providing for approval of development within property that includes any regulated area as defined in Section 4-02.2.2.A, ERZ Watercourses, shall identify and delineate the regulated areas and the protected riparian area on the property and shall comply with this standard. The boundary of the regulated area and the protected riparian area should be clearly depicted on applicable submittal documents. The Naylor Wash is subject to the WASH Regulations (per TCC 29 Art. VIII, sec 29-14) and the "regulated area" includes channel and banks of a watercourse and the area within 50 feet of the top of the bank, or where there is no defined bank, 50 feet from the ten-year flood boundary. 2) AM 4-02.2.6.A Ownership of PRA Ownership of the protected riparian area shall be provided in one or more of the methods set forth below to insure continued preservation of the area. Forms of ownership of protected riparian areas include: "A. protected riparian areas for proposed subdivisions may be either publicly owned, owned by a common association, or owned by a non-profit association which provides for conservation management. " The response letter indicates that there is no common association or other public or private association designated to provide conservation management. It appears that a Technical Standards Modification Request (TSMR) per TSM 1-01.6.1.A will be required due to non-conformance with the standard. 3) AM 4-02.2.6.A D. Where the protected riparian area is on property that remains under the ownership of a single person or entity following the development, the protected riparian area shall be protected through a conservation or public easement or other legal restriction upon further development. In order to establish the extent of the protected riparian area on this site, an Environmental Resource Report per TSM 4-02.2.4.B.1 is required. |
| 10/14/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) two rolled copies of the plans 2) all items requested by staff 3) all items need to approve this plan. |
| 10/14/2013 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/15/2013 | CPIERCE1 | REJECT SHELF | Completed |