Review Date Reviewer's Name Type of Review Description Status Comments
07/26/2013 SPOWELL1 START PLANS SUBMITTED Completed
07/26/2013 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed Approved on first review.
07/29/2013 MWYNEKE1 PIMA COUNTY WASTEWATER Approved PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 724-6500
DIRECTOR FAX: (520) 620-0135

July 24, 2013

To: Jeff Hunt, P.E., Project Manager
Cypress Civil Development, L.L.C.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Michael J. Harrington, Sr. Civil Engineering Assistant
Development Liaison Unit

Subject: FINAL PLAT Minor Subdivision, 18th & Main
Final Plat - 1st Submittal, S13-015, DLU13-116 (PSL), Review Comments

The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department.

The PDEQ and the PCRWRD hereby reject the above referenced submittal of the Final Plat as received by us on July 17, 2013, for the following reasons:

1. Sheet 1 of 2: GENERAL NOTES block, Item #8: With no underground utilities shown or required on the final plat it would be appropriate to delete item #8.

2. Sheet 1 of 2: SURVEYOR"S block, bottom left corner: Revise and correct the Sheet count.

3. Sheet 1 of 2: PROPERTY INFORMATION block: The "Owner/Developer/Archetect" is identified here with relevant property information but without any contact information. Contact City of Tucson DSD staff to see if an OWNER/DEVELOPER block is also required along with the contact information needed to identify and contact a responsible developer party. Also, check the spelling of the word architect.

4. Sheet 1 of 2: GENERAL SEWER NOTES block: There are no requirements for general sewer notes on the final plat. This heading is not needed or desired on the final plat.

5. Sheet 1 of 2: GENERAL SEWER NOTES block, Item #4: This note is not needed or desired on the final plat.



6. Sheet 1 of 2: GENERAL SEWER NOTES block, Item #8: This note is not needed or desired on the final plat.

7. Sheet 1 of 2: GENERAL SEWER NOTES block, Item #11: This private sewer operation/maintenance note is not needed under the general sewer notes heading but it is relevant and should be included on the final plat. Move this note to the General Notes block and renumber, as appropriate.

8. Sheet 1 of 2: GENERAL SEWER NOTES block, Item #17: This private sewer construction permit note is not needed under this heading but it is relevant and could be included on the final plat. Move this note to the General Notes block and renumber, as appropriate.

9. Sheet 2 of 2: Due to size, condition, age and potential sewer gas odor issues; Lots 2 and 3 will not be allowed to connect to the 33" public interceptor sewer (G-62-44) which fronts these lots in 18th Street, without a special approval process. Furthermore, the cost associated with flow-management, traffic control, design and construction make any connections to this 33" main, pipe or manhole, cost prohibitive. Provide a Private Sewer Easement across the north end of the property (10' typical), as spelled out in the preliminary sewer layout (PSL) review documents filed under case number DLU13-116. This easement would typically be recorded per "this final plat" not by separate instrument as indicated on the PSL.

a. If you determine that the location cannot be determined at this time, add a paragraph to the DEDICATION block on Sheet 1, that states something like:

AN ASSOCIATION OF PROPERTY OWNERS WILL BE FORMED TO ACCEPT RESPONSIBILITY AND LIABILITY FOR CONSTRUCTION, MAINTENANCE, OPERATION AND CONTROL OF PRIVATE SEWERS AND OTHER COMMON ELEMENTS.

b. Another acceptable alternative is for this arrangement to be documented within Covenants, Conditions and Restrictions (CC&Rs) recorded and appropriately referenced in the DEDICATION block.

The next submittal will be the second submittal for this Final Plat. The RWRD review fee for the second submittal will be $100.00 (Per PC Code, Title 13.20.030.A.2). Please let me know if you have any questions.



Michael J. Harrington, Sr. CEA
Planning and Engineering - Development Liaison Unit




Cc: Francisco Galindo, P.E., RWRD
Chad Amateau, P.E., RWRD
Kristin L. Greene, P.E., RWRD
Project file, T14S, R13E, Section 13
07/29/2013 MWYNEKE1 PIMA COUNTY WASTEWATER Approved PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 724-6500
DIRECTOR FAX: (520) 620-0135
August 1, 2013

To: Jeff Hunt, P.E., Project Manager
Cypress Civil Development, L.L.C.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Michael J. Harrington, Sr. Civil Engineering Assistant
Development Liaison Unit

Subject: FINAL PLAT Minor Subdivision, 18th & Main
Final Plat - 2nd Submittal, S13-015, DLU13-116 (PSL), Review Comments

The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department.
The drawings of the Final Plat for the proposed project have been reviewed on behalf of Pima County Department of Environmental Quality (PDEQ) and Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to either Department. The following comments are offered.
PCRWRD hereby approves the above referenced submittal of the Final Plat received by us on May 23, 2013.
Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) will need to be obtained from PDEQ.
If you have any questions regarding the above comments, please contact me.


Michael J. Harrington, Sr. CEA
Planning and Engineering - Development Liaison Unit




: Francisco Galindo, P.E., RWRD
Chad Amateau, P.E., RWRD
Kristin L. Greene, P.E., RWRD
Project file, T14S, R13E, Section 13
07/29/2013 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV, 1ST FL
TUCSON, AZ 85701-1207


MICHELENE NOWAK
ADDRESSING REVIEW
PH #: 721-9512



TO: CITY PLANNING
FROM: MICHELENE NOWAK, ADDRESSING REVIEW
SUBJECT: S13-015/FINAL PLAT 18TH/MAIN SUBDIVISION
DATE: July 29, 2013




The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
07/30/2013 JIM EGAN COT NON-DSD FIRE Approv-Cond An approved fire hydrant with the capability of providing 1,000GPM for 2hours at 20psi residual pressure is required to be within 600 feet of all exterior walls along the fire apparatus access route, for any future single family homes. Any commercial structures will require a higher fire flow with fire hydrants located closer.
08/01/2013 PGEHLEN1 PIMA COUNTY SOUTHWEST GAS Approv-Cond See letter in SIRE from first review.
08/07/2013 MICHAEL ST. PAUL ZONING REVIEW Approved
08/16/2013 ELIZABETH LEIBOLD ENGINEERING REVIEW Denied TO: Everett Trueblood R.L.S.
SUBJECT: S13-015 Final Plat 2nd submittal Minor Subdivision Engineering Review
ADDRESS: 695 S MAIN AV, Ward 6
LOCATION: T14S R13E Section 13
FLOODPLAIN: FEMA zone X-unshaded, 2279L
REVIEWER: Elizabeth Leibold, P.E.

SUMMARY: Engineering has reviewed and provided remaining comments to the revised final plat sheets for18th and Main subdivision. Per AM 2-06.4.1, applicable registration seal and signature shall be provided if prepared by or with the assistance of a registered professional surveyor. All sealing shall be consistent with AZ BTR guidelines. Comments were outstanding since surveyor's seal were not provided.
Engineering does not recommend approval of the Final Plat at this time. Prior to resubmittal, address the remaining plat comments.

MASTER COVER SHEETS/ GENERAL NOTES:
10) AM 2-07.5.3.E: Add punctuation at end of sentence for Assurance paragraph on sheet 1.

SURVEY RELATED COMMENTS:
12) AM 2-07.5.5.A: Assure that survey information on planview indicates that at least one corner of the plat shall be tied with bearing and distance to a section corner, a quarter section corner or an established COT survey monument.
13) AM 2-07.5.5.B: Assure that all easements are clearly drawn, labeled with sequence number or Book/page or Docket/page, and/or listed as a blanket easement, and/or labeled with accurate dimensions and bearings on the plat.
15) AM 2-07.5.5.C.4: State whether the property corner nail information for SW corner of project, near north curb return, that was provided was actually found at site, since no seal was provided on resubmittal.

Submit revised Final Plat sheets sealed by registrant, Title Report Schedule B, and response letter. Please call me to set up a meeting prior to resubmittal to expedite resubmittal review, or call for clarifications at 837-4934.

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Department
08/19/2013 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Denied This review has been completed.

Resubmittal is required.

Please resubmit the following items:

1) Two rolled sets of the plans
2) All items requested by review staff
3) All items needed to approve this plan.
08/19/2013 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)


FROM: Ada Griffin
GIS Cartographer
Pima County Assessor's Office


DATE: August 15, 2013


RE: Assessor's Review and Comments Regarding:

S13-015-18th/MAIN-SUBDIVISION

_

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.

COMMENTS:

Thank you for your submittal



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
08/19/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied Resubmittal requirements are under the record folder.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/21/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed