Plan Review Detail
Review Status: Completed
Review Details: MINOR SUBDIVISION REVIEW
Plan Number - S13-006
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/26/2013 | CPIERCE1 | START | PLANS SUBMITTED | Completed | |
| 05/02/2013 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: May 2, 2013 SUBJECT: Valenzuela Subdivision Minor Subdivision Plat Submittal- 2nd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 5885 S Jeanette Blvd, T15S R14E Sec07 Ward 5 REVIEWER: Jason Green, CFM ACTIVITY: S13-006 SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Minor Subdivision Plat and Title Report. Engineering Division has reviewed the submitted Final Plat and recommends conditional approval at this time. The following item need to be addressed prior to submitting the Final Plat Mylar to CDRC: FINAL PLAT COMMENTS: 1) AM Sec.2-07.5.1.D: Revise the Final Plat Mylar to place the words "SEQ#____" in both the upper and lower right corners outside the margin lines on each sheet. The Plat currently has it in only one place in the lower middle, revise. GENERAL COMMENTS: Provide the Final Plat Mylar at re-submittal addressing the above comments. For questions or to schedule a meeting I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Planning & Development Services |
| 05/06/2013 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St Paul Planning Technician PROJECT: S13-006 5885 S. Jeanette Blvd. Minor Subdivision Final Plat TRANSMITTAL: May 6, 2013 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Unified Development Code (Section 8.4.1) and the Administrative Manual (Section 2-07) were addressed. 1) Place the subdivision case number S13-006 in the lower right corner of each sheet next to the title block (AM 2-07.5.1.H). (Notice the green lines.) 2) Identify each lot within the subdivision boundary as Lot 1, Lot 2, and Lot 3 (AM 2-07.5.4.B), rather than as parcel numbers, and revise the title of the plat. (Notice the green lines.) 3) A design Development Option (DDO) shall be required for the setback proposed for what is presently identified as Parcel 2. The proposed shed locations can be signed for on the plot plans by the adjacent owners, who are the same people. 4) If you do not already have an application for the DDO, acquire from the front counter. You may also be able to get one on line at this location: http://cms3.tucsonaz.gov/sites/default/files/planning/ddo_for_building_setback_and_patio_wall_height.pdf 5) Note: Plot plans, floor plans and elevations shall be required. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9 & .10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). A DDO is required for the setback from the SFR to the proposed property line to the south. The required setback is seven (7) feet, ten (10) inches. The proposed setback is five (5) feet, two (2.5) and a half inches. |
| 05/06/2013 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV, 1ST FL TUCSON, AZ 85701-1207 MICHELENE NOWAK ADDRESSING REVIEW PH #: 721-9512 TO: CITY PLANNING FROM: MICHELENE NOWAK, ADDRESSING REVIEW SUBJECT: S13-006/VALENZUELA SUBDIVISION –FINAL PLAT REVIEW DATE: May 6, 2013 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. 1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 05/06/2013 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: A Minor Subdivision - Valenzuela S13-006 Tucson Electric Power Company (TEP) has reviewed and approves the final plat submitted April 29, 2013. If you have any questions, please contact me at 917-8744. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQW603 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 05/07/2013 | PGEHLEN1 | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 May 7, 2013 To: Donald J. Loose, Project Manager Atlas Land Survey, Inc. Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Francisco Galindo, P.E. RWRD, Development Liaison Unit Subject: Valenzuela Subdivision, Parcels A-C Final Plat - 2nd Submittal, S13-006, Review Comments The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. PCRWRD hereby approves the above referenced submittal of the Final Plat received by us on April 29, 2013. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) will need to be obtained from PDEQ. If you have any questions regarding the above comments, please contact me. Michael J. Harrington, Sr. CEA Planning and Engineering - Development Liaison Unit Cc: Chad Amateau, P.E., RWRD Kristin L. Greene, P.E., RWRD Project file, T15S, R14E, Section 7 |
| 05/20/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | This review has been completed and resubmittal is required. The resubmittal must include" 1) Two rolled sets of the plans 2) a disk containing all items submitted. 3) All items requested by review staff 4) All items used to approve the plans. |
| 05/20/2013 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Denied | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ada Griffin GIS Cartographer Pima County Assessor's Office DATE: 05/20/13 RE: Assessor's Review and Comments Regarding S13-006 VALENZUELA SUBDIVISION, A MINOR SUBDIVISION * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. ___X___ Plat does not meet Assessor's Office requirements. COMMENTS: THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER, MUST MENTION THE PLAT NAME AND THE MAP AND PLAT, OF THE RESUBDIVISION THE LOCATION MAP IN THE UPPER RIGHT HAND CORNER, MUST HAVE THE SECTION, TOWNSHIP ANS RANGE THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND SUBDIVISION NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/21/2013 | CPIERCE1 | REJECT SHELF | Completed |