Plan Number: S13-006
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S13-006
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2013 CPIERCE1 START PLANS SUBMITTED Completed
02/01/2013 PGEHLEN1 PIMA COUNTY WASTEWATER Approv-Cond PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135
February 1, 2013

To: Donald J. Loose, Project Manager
Atlas Land Survey, Inc.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Brandon Matheson, P.E., CE Manager
RWRD, Development Review Manager

Subject: Valenzuela Subdivision, Parcels A-C
Final Plat - 1st Submittal, S13-006, Review Comments

The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department.
PCRWRD hereby approves the above referenced submittal of the Final Plat received by us on January 30, 2013 subject to following.
" The Title block in the upper right corner states: PARCEL A - F. The plat shows only three parcels, A, B & C. Please rectify.
" In the Dedication block, second paragraph: After the words …GRANT TO, add the words, CITY OF TUCSON… After the words …PIMA COUNTY, delete the words, WASTE WATER MANAGEMENT…
Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) will need to be obtained from PDEQ.

If you have any questions regarding the above comments, please contact me.


Michael J. Harrington, Sr. CEA
Planning and Engineering - Development Liaison Unit

Cc: Chad Amateau, P.E., RWRD
Kristin L. Greene, P.E., RWRD
Project file, T15S, R14E, Section 7
02/04/2013 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved see Letter in SIRE
02/04/2013 JIM EGAN COT NON-DSD FIRE Approved
02/05/2013 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved Regional Traffic Engineering has no comments on this submittal and recommends its acceptance. Thank you.

________________________________

Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
.
02/08/2013 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St Paul Planning Technician

PROJECT:
S13-006
5885 S. Jeanette Blvd.
Minor Subdivision Final Plat


TRANSMITTAL: January 22, 2013


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Unified Development Code (Section 8.4.1) and the Administrative Manual (Section 2-07) were addressed.


1) The consultants and owners attend a pre-submittal meeting and the final plat for a minor subdivision was approved for submittal on January 12th of 2013 (UDC 8.4.1.C).

2) An applicant has one year for the date of application to obtain approval of a site plan or final plat (UDC Section 3.3.3.G.5.c).

3) Place the subdivision case number S13-006 in the lower right corner of each sheet next to the title block (AM 2-07.5.1.H).

4) Use the exact working provided in Administrative Manual for the Certification of Survey (AM 2-07.5.3.A).

5) Provide the information in the Approval exactly as presented in the Administrative Manual (AM 2-07.5.3.D). The City Clerk is Roger Randolph.

6) Identify each lot within the subdivision boundary by number, and include the square footage of each (AM 2-07.5.4.B).

7) Depict the structures only on the plot plans and remover them from the final plat.

8) The scale for parcel A is too small. Try using 11" x 17" sheets for the plot plans.

9) A design Development Option (DDO) shall be required for the setback proposed for what is presently identified as Parcel B.

10) If you do not already have an application for the DDO, acquire from the front counter. You may also be able to get one on line at this location: http://cms3.tucsonaz.gov/sites/default/files/planning/ddo_for_building_setback_and_patio_wall_height.pdf

11) Note: Plot plans, floor plans and elevations shall be required.

12) DDO comments shall be provided at the time when proper drawings are provided.
02/11/2013 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Here are my comments -

DATE: 2/11/2013
CASE: S13-006 MINOR SUBDIVISION
COMMENT: No objections or adverse comments

Daily PM Peak
Vehicle Trip Generation: 0 0

Thanks,
-Eric
02/19/2013 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
02/20/2013 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
02/21/2013 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: A Minor Subdivision - Valenzuela
S13-006


Tucson Electric Power Company (TEP) has reviewed and approves the final plat submitted January 30, 2013.

Please forward any future submittals of this plat to our office.

If you have any questions, please contact me at 917-8744.

Thank you,

Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com<mailto:mburke@tep.com>
02/21/2013 PGEHLEN1 COT NON-DSD TUCSON POLICE DEPARTMENT Approved I have no issues with this request.

CSO Becky Noel #37968
Tucson Police Dept
837-7428
02/22/2013 RONALD BROWN ZONING HC REVIEW Passed
02/25/2013 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: February 26, 2013
SUBJECT: Valenzuela Subdivision Minor Subdivision Plat Submittal- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 5885 S Jeanette Blvd, T15S R14E Sec07 Ward 5
REVIEWER: Jason Green, CFM
ACTIVITY: S13-006

SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Minor Subdivision Plat and Title Report. Engineering Division has reviewed the submitted Final Plat and does not recommend approval at this time. Refer to the links for further clarification:
http://cms3.tucsonaz.gov/files/planning/UDC_ADOPTED_100912.pdf; http://cms3.tucsonaz.gov/files/planning/Technical_Manual_ADOPTED_100912.pdf; http://cms3.tucsonaz.gov/files/planning/Admin_Manual_ADOPTED_100912.pdf

The following items need to be addressed:

FINAL PLAT COMMENTS:

1) AM Sec.2-07.1: Revise the Final Plat to remove all buildings, sight visibility triangles, driveway references, access gates, fencing, meters, hydrants, etc. The Final Plat is to show only surveyable and boundary information. The other structures, SVTs, access gate references, fencing, meters, hydrants, etc must be shown on the supplemental house exhibits only.

2) AM Sec.2-07.5.1.A.4: Revise the Final Plat and the Location Map to label the subdivisions with recordation information within the 1-mile area.

3) AM Sec.2-07.5.1.E: Revise the Final Plat to provide the Title Block in the lower right corner of each sheet. Provide the subdivision name, number of lots and the legal description by section, township and range. Also provide the resubdivision of a previously recorded plat.

4) AM Sec.2-07.5.1.H: Revise the Final Plat to place the assigned subdivision case number "S13-006" in the lower right corner of the plat next to the Title Block.

5) AM Sec.2-07.5.3.A: Revise the Final Plat and the Certification Survey paragraph to read per the referenced standard; "I hereby certify that the boundary survey as shown on this plat was performed under my direction and that all existing or proposed survey monuments and markers shown are correctly described. I further certify that this plat was prepared under my direction."

6) AM Sec.2-07.5.3.E: Revise the Final Plat and Assurance Block to provide the correct signature lines per the referenced standard;
_____________________________________________
City of Tucson Development Services Department Director
_________________________________________________________
City of Tucson Development Services Department Engineering Administrator

7) AM Sec.2-07.5.4.A: Revise the Final Plat to label all roadways as "Public," Remove the Typical cross sections for the roadways and instead provide the right-of-way dimensions on the plat with the appropriate dedication notation.

8) AM Sec.2-07.5.5.A: Revise the Final Plat so at least one corner of the subdivision is tied by course and distance to a section corner or an established survey monument.

9) AM Sec.2-07.5.5.C.2: Revise the Final Plat to provide a reference to the Basis of bearings. The purpose of the basis of bearings on a survey is to enable another surveyor to retrace the original survey. As such, the statement must be referenced to found, readily locatable monuments. The basis of bearings should be established from two (2) found, physically monumented points described and shown on the final plat. If the monuments at each end of the reference line are fully described on the plat, they need not be described in the "Basis of Bearings" statement.

GENERAL COMMENTS:

Provide a revised Final Plat at re-submittal addressing the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For questions or to schedule a meeting I can be reached at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
02/27/2013 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved January 31, 2013

Maria C. Valenzuela
5885 S. Jeanette Blvd
Tucson, AZ 85706

Attn: Maria C. Valenzuela

SUBJECT: Water Availability for project: 5885 S. Jeanette Blvd, APN: 14025063A, Case #: S13-006, T-15, R-14, SEC-07, Lots: 237, Location Code: TUC, Total Area: 1.7ac,
Zoning: R-2

WATER SUPPLY
Tucson Water will provide water service to this project based on the subject zoning of the above parcels. Tucson Water has an assured water supply (AWS) designation from the State of Arizona Department of Water Resources (ADWR). An AWS designation means Tucson Water has met the criteria established by ADWR for demonstration of a 100-year water supply - it does not mean that water service is currently available to the subject project.

WATER SERVICE
The approval of water meter applications is subject to the current availability of water service at the time an application is received. The developer shall be required to submit a water master plan identifying, but not limited to: 1) Water Use; 2) Fire Flow Requirements; 3) Offsite/Onsite Water Facilities; 4) Loops and Proposed Connection Points to Existing Water System; and 5) Easements/Common Areas.

Any specific area plan fees, protected main/facility fees and/or other needed facilities' cost, are to be paid by the developer. If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be financially responsible for modifying or enhancing the existing water system to meet those needs.

This letter shall be null and void two years from the date of issuance.

Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development.

If you have any questions, please call New Development at 791-4718.

Sincerely,


Scott Schladweiler, P.E.
Engineering Manager
Tucson Water Department

SS:bjp
CC:File
02/27/2013 PGEHLEN1 ENV SVCS REVIEW Approved This Plat is approved by Environmental Services for residential waste and recycling in City boundaries.





Jeff Drumm, P.E.
Environmental Manager
City of Tucson Environmental Services
520-837-3713
02/28/2013 ED ABRIGO PIMA COUNTY ASSESSOR Denied Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)


FROM: Suzanne Gilpin
GIS Cartographer
Pima County Assessor's Office


DATE: February 27, 2013


RE: Assessor's Review and Comments Regarding Final Plat
S13-006/MINOR SUBDIVISION


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
_X ____ Plat does not meet Assessor's Office requirements.

COMMENTS:

" OWNERS NAME OF RECORD IS MARIA C VALENZUELA AND NOT MARIA VALENZUELA AS STATED ON PLAT.
" THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION
" TOP RIGHT CORNER OF PLAT STATES PARCELS A-F, AND A-C SHOW ON PLAT.
" ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED WITH MAP & PLAT IN APPROPRIATE AREAS AROUND SUBDIVISION.



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
02/28/2013 JOE LINVILLE LANDSCAPE REVIEW Approved
02/28/2013 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved
02/28/2013 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Passed
02/28/2013 KAY MARKS PIMA COUNTY ADDRESSING Denied TO:

CITY PLANNING

FROM:

AUDREY FARENGA, BY M. NOWAK, ADDRESSING REVIEW

SUBJECT:

S13-006/VALENZUELA SUBDIVISION

DATE:

February 28, 2013




The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


1. Spell out street suffix for: Jeanette Boulevard
2. Correct street suffix and spell out for: Alvord Road
3. Remove: PARCELS A - F as shown in heading
4. Correct quarter to N.W. ¼ of Section 7 as shown in heading
03/01/2013 PGEHLEN1 UTILITIES EL PASO NATURAL GAS Passed
03/01/2013 PGEHLEN1 OTHER AGENCIES U. S. POST OFFICE Passed
03/01/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed. Revisions are required. The resubmittal must include 4 rolled sets of the plans, 1 folded set of the plans (RWRD), a disk with copies of all plans and items submitted, and all other items requested by review staff. RWRD may charge additional fees for the 2nd review.
03/01/2013 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
03/01/2013 PGEHLEN1 UTILITIES CENTURYLINK Passed
03/01/2013 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
03/01/2013 CPIERCE1 OUT TO CUSTOMER Completed