Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S13-003
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/03/2013 | MWYNEKE1 | START | PLANS SUBMITTED | Completed | |
| 05/20/2013 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: May 20, 2013 SUBJECT: Chase Bank at Ajo and 16th Final Plat Submittal- 2nd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 728 W Ajo Way, T14S R13E Sec26 Ward 1 REVIEWER: Jason Green, CFM ACTIVITY: S13-003 SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Final Plat and Title Report. Engineering Division has reviewed the submitted Final Plat and recommends conditional approval at this time. The following items need to be addressed: FINAL PLAT COMMENTS: 1) Restated: AM Sec.2-07.5.1.A.4: Revise the Final Plat and the Location Map to label the subdivisions with Book and Page. 2) Restated: AM Sec.2-07.5.4.F: Revise the Final Plat to label and dimension the limits of the 100-year floodprone area in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines. Include the symbol within the legend on Sheet 2 with a description. The regulatory wash that is adjacent to 16th Ave has a 100-year floodplain limit associated with it and must be shown on the plat. GENERAL COMMENTS: Provide a Final Plat Mylar at re-submittal addressing the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. For questions or to schedule a meeting I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Planning & Development Services |
| 05/20/2013 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Denied | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ada Griffin GIS Cartographer Pima County Assessor's Office DATE: 05/20/13 RE: Assessor's Review and Comments Regarding - * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. ___X___ Plat does not meet Assessor's Office requirements. COMMENTS: -THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER; MUST LIST NUMBER OF LOTS -GENERAL NOTES MUST HAVE THE BASIS OF BEARING -MISSING ADJACENT SUBDIVISIONS NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION -OWNERSHIP DOES NOT MATCH; WE SHOW: VALLEY NATIONAL BANK OF AZ NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 05/22/2013 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera, Principal Planner for Terry Stevens, Lead Planner PROJECT: S13-003 728 W. Ajo Way Minor Subdivision Plat TRANSMITTAL: 05/22/2013 DUE DATE: 06/03/2013 COMMENTS: 1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 2. The previous comment was not addressed completely as requested. The existing subdivision book and page recording within the 1 mile mapped area were not listed on the location map. Portion of the Previous Comment: AM Sec.2-07.5.1.A - A project-location map must be drawn in the upper right corner of the first sheet of the plat at a scale of 3" = 1 mile and include the following information: List the book and page recording information for existing subdivisions within the 1 mile area. 3. The previous comment was not completely addressed as requested: Revise the title block as follows. List the following text "Lots 1 and 2, Being a resubdivision of a portion etc." under the words Chase at Ajo and 16th Previous comment left in it's entirety as reference: AM 2-07.5.1.E, Provide a title block in the lower right corner of each sheet with the following information: 1. Subdivision name; number of blocks, lots, and/or units; and common area; 2. Legal description by section, township, and range; and, 3. If the final plat is a resubdivision of a previously recorded plat, indicate the title and the book and page/sequence number reference of the existing subdivision. If you have any questions about this transmittal, please call David Rivera or Terry Stevens, (520) 791-5550 TLS C:\planning\cdrc\finalplat\S13-003fp2.doc |
| 05/31/2013 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: CHASE BANK FINAL PLAT S13-003 Tucson Electric Power Company (TEP) has reviewed and approves the final plat submitted for review May 3, 2013. If you have any questions, please feel free to contact me. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQW603 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 05/31/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) A disk that contains all items submitted 3) All items requested by reviewers 4) All items needed to approve the plan. |
| 05/31/2013 | PGEHLEN1 | PIMA COUNTY | WASTEWATER | Denied | Applicant did not submit plans to RWRD. |
| 05/31/2013 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/25/2013 | CPIERCE1 | REJECT SHELF | Completed |