Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S12-055
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2013 | PGEHLEN1 | UTILITIES | SOUTHWEST GAS | Approved | Comments are in SIRE |
| 01/03/2013 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | DATE: January 2, 2013 TO: Jeff Behrana, P.E., OPTIMUS ACTIVITY: S12-055 PROJECT: Tucson Marketplace Phase 3 Final Plat - 1st review LOCATION: Ward 5 FEMA: 2237K, Zone X-Unshaded WATERSHED: Mission View Wash Watershed adjacent to Greyhound Wash Detention Area REVIEWER: Elizabeth Leibold, P.E. SUMMARY: The Final Plat Development Package for the Phase 3 of the Tucson Market Place was received and reviewed by Planning & Development Services Department Engineering. PDSD Engineering does not recommend approval until the following items are addressed. COMMENTS: 1) City of Tucson Administrative Manual Section No. 2-07.5.1.A.2: Label section corners in project location map. Also, an extra line is showing up for west section line; correct/clarify. 2) Admin. Man Secs.2-07.5.1.A.4, 2-07.5.1.G : Label Greyhound Wash and clarify centerline for I-10 in project location map. 3) Admin. Man Sec.2-07.5.1.B: Clarify think lines shown on sheet 2 in legend. 4) Admin. Man Sec.2-07.5.1.C: Describe and clarify PAD. 5) Admin. Man Sec.2-07.5.1.E.1: In Title Blocks on each sheet, add/provide "lots 1-5". 6) Admin. Man Sec.2-07.5.1.H: Add plat case number: S12-055 next to Title Block on each sheet. 7) Admin. Man Secs.2-07.5.2.A&B: See redlines and add to general note 1 for "gross area of this subdivision". 8) Admin. Man Sec.2-07.5.3.B.1: Assure verbiage matches this section of the requirements. 9) Admin. Man Sec.2-07.5.3.B.2.b: Add this section of the requirements regarding Dedication language. 10) Admin. Man Sec.2-07.5.3.E: Add missing verbiage (last sentence) per this section of the requirements. "… In the event that any such assurance expires, lapses or is otherwise inadequate to assure the completion of assurable infrastructure, the City may suspend the issuance of building permits or certificates of occupancy." 11) Admin. Man Sec.2-07.5.4.K: Explain how this section of the requirements is met - phasing notes or otherwise. 12) Admin. Man Sec.2-07.5.5.B: All easements within the platted area shall have dimensions and bearings or otherwise surveyable. See redlines. 13) Admin. Man Sec.2-07.5.5.C: All boundary monuments shall be found or set. Describe all lot boundary corners for Block 6 and new lots on plat planviews. For clarification, a note to general notes or legend may be added per section 2-07.5.5.C.4.b. Also, indicate lines as either measured or calculated; for clarification, a note to general notes or legend may be added per section 2-07.5.5.C.5. 14) Admin. Man Sec.2-07.5.6: If lot corners are not set, assurances may be required. 15) Admin. Man Sec.2-07.6.1.B: See redline comments. Return redlines. Set up a meeting to go over comments before resubmittal. If you have any questions, please call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services |
| 01/07/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | Corrections required. Resubmit 3 rolled sets of the plan and a disk. |
| 01/07/2013 | PGEHLEN1 | PIMA COUNTY | WASTEWATER | Approved | Approval letter is in SIRE. |
| 01/07/2013 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 01/07/2013 | PGEHLEN1 | UTILITIES | CENTURYLINK | Passed | |
| 01/07/2013 | PGEHLEN1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Passed | |
| 01/07/2013 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Reqs Change | AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: S12-055 TUCSON MARKETPLACE PHASE 3/FINAL PLAT DATE: January 7, 2013 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1. Include Lots 1 - 5 on all title blocks. 2. Label Tucson Marketplace Boulevard on all sheets. |
| 12/18/2012 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/18/2012 | PGEHLEN1 | COT NON-DSD | REAL ESTATE | Passed | |
| 12/20/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Tucson Marketplace - Phase 3 S12-055 (1st Review) Final Plat TRANSMITTAL DATE: December 24, 2012 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before October 30, 2013. 2. D.S. 2-03.6.1.D.3 Label the section corners on the location map. 3. D.S. 2-03.6.1.F If the project is located within the boundaries of a Planned Area Development (PAD) zone, such as Williams Addition, Gateway Center, Tucson Community Center, Rio Nuevo, La Entrada, or Civano, include a reduced-scale map of the entire PAD District on the first sheet, indicating the location of the portion being developed. 4. D.S. 2-03.6.1.H The title block should include the number of proposed blocks for this subdivision. 5. D.S. 2-03.6.1.K Provide the S12-055 in the lower right corner of the plat next to the title block. 6. D.S. 2-03.6.1.K Provide the rezoning case number C9-06-32 in the lower right corner of the plat next to the title block. 7. D.S. 2-03.6.2.A The gross area of the subdivision should include the entire acreage of Block 6. 8. D.S. 2-03.6.2.B The total number of lots listed under General Note 2 is not correct. The total should reflect 6 as the remaining area of Block 6 should be counted as Lot 6. 9. D.S. 2-03.6.2.B Sheets 2, 3, 4 & 5 within the plat map revise all references to "BLOCK 6" to Lot 6. 10. D.S. 2-03.6.2.D Provide a general note stating ""THIS PLAT IS SUBJECT TO THE CONDITIONS OF REZONING CASE NUMBER C9-06-32, UNLESS SUPERSEDED BY A SUBSEQUENT REZONING ORDINANCE." 11. D.S. 2-03.6.6 The Declaration of Reciprocal Easements and of Covenants and Restrictions with need to be revised to reflect the changes to Block 6. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C\planning\cdrc\finaplat\s12-015fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat & revised Declaration of Reciprocal Easements and of Covenants and Restrictions |
| 12/20/2012 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Sherry Hyde Senior Property Technician Pima County Assessor's Office DATE: 12/19/12 RE: Assessor's Review and Comments Regarding S12-055 TUCSON MARKETPLACE-PHASE 3 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. ___X____Plat does not meet Assessor's Office requirements. COMMENTS: " THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER NEEDS TO STATE THE NUMBER OF LOTS BELOW "TUCSON MARKETPLACE - PHASE 3. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 12/27/2012 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: FINAL PLAT FOR TUCSON MARKETPLACE - PHASE 3 S12-055 Tucson Electric Power has reviewed and approves the Final Plat for the above commercial subdivision received on December 19, 2012. Any additional easements required for installation of electrical facilities will be obtained by separate instrument. If there are any questions concerning this correspondence, please contact me at 917-8744. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQW603 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/13/2013 | CPIERCE1 | REJECT SHELF | Completed |
| 02/13/2013 | CPIERCE1 | OUT TO CUSTOMER | Completed |