Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S12-043
Parcel: Unknown

Address:
10411 E BILBY RD

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S12-043
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2012 CPIERCE1 START PLANS SUBMITTED Completed
07/31/2012 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co. (TEP) approves the amended final plat submitted for review Friday, July 20, 2012.

Please contact me at 520-917-8745 if you have any questions.


Mary Burke
Right of Way Agent
Tucson Electric Power Company
Mail Stop HQW603
PO Box 711
Tucson, AZ 85702
520-917-8744 Office
520-401-9895 Cell
mburke@tep.com
07/31/2012 JWILLIA4 PIMA COUNTY WASTEWATER Passed
08/01/2012 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Denied PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S12-043 Civano II Revision Final Plat 8/1/12

(X) Final Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(X) Other - Construction Documents for Miniparks

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Civano PAD

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY: 8/21/12

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
(X) Final Plat
() Development Plan
() Landscape Plan
(X) Other - Construction Documents for Miniparks


REVIEWER:JB 837-6966 DATE: 08/1/12
Planning and Development Services Department
Community Planning Section
S12-043
August 1, 2012


Staff offers the following comments:

1. Please correct and revise the Final Plat to show the new lot / site configuration for the miniparks. Please label and identify the new square footage for the minipark areas.

2. Please correct the case reference on sheet 1 to read 'S97-035' instead of '297-035'. I believe this is an error.
08/09/2012 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
S12-043 (DP12-0121)
Civano II, Resubdivision
Final Plat; 1st review


TRANSMITTAL: August 8, 2012


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is July 30, 2013.

2) Provide the new subdivision case number S12-043 in the lower right corner of the plant next to the title block of the Development Plans, and the Tentative and Final Plats, with all the other CDRC references (DS 2-03.2.2.B.1).

3) The minimum lot size for the mini-parks is four thousand, five hundred (4,500) square feet (Civano PAD, Master Development Plan C-3 Definitions, Mini-Parks: p.56).

4) The plans as presented define the mini-parks as an expansion of Common Area "C" Arbor Walks. The area calculations for Common Area "C" appear to include the square footage of the lots (2,070 square feet for each lot) to be absorbed into the common area. The minimum lot size requirement is thereby resolved.

5) The plat must represent the common area as defined. Remove the lot lines from the former parcels. Simply delineate parks as an expansion of Common Area "C" on the tentative and final plat drawings, along with the Development Plan drawings.

6) There are no further comments at this time.
08/13/2012 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207

AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S12-043 CIVANO II/ AMENDED FINAL PLAT
DATE: August 13, 2012



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

On the Final Plat:

1. Under the Location Map change section 1 to 12.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***
08/14/2012 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 08/14/2012,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Civano II
S12-043, T15S, R15E, SECTION 12
Reference S03-021 and DP12-0121

RECEIVED: Revised Final Plat on July 20, 2012

The subject submittal has been reviewed. The Final Plat shall be recommended approval pertaining to Engineering and Floodplain, after to the following comments have been satisfactorily addressed:

1. Provide the complete case # (i.e. S12-043) as required by D.S. 2-03.6.1.K.
2. Remove the lot lines between the affected lots and the Arbor Walks to show the lots as part of Common Area "C".
3. Since the converted lots are intended to be parks, revise the description of Common Area "C" to include "Parks". Revise the Title Block accordingly.


RESUBMITTAL REQUIRED: Revised Final Plat
08/15/2012 ED ABRIGO PIMA COUNTY ASSESSOR Approv-Cond Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor's Office


DATE: 7/23/12


RE: Assessor's Review and Comments Regarding
S12-043 CIVANO II


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.

COMMENTS: THE LOCATION MAP IN THE UPPER RIGHT HAND CORNER STATES THE PROJECT IS IN SECTION 1, TOWNSHIP 15, RANGE 15E. IT SHOULD BE SECTION 12 LIKE THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
08/20/2012 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
08/21/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied This review has been completed. Resubmittal is required.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/18/2012 CINDY AGUILAR OUT TO CUSTOMER Completed