Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S12-013
Parcel: Unknown

Address:
2350 N 1ST AV

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S12-013
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/05/2012 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/12/2012 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor’s Office


DATE: 3/12/12


RE: Assessor’s Review and Comments Regarding
S12-013 WALGREENS & PAD A: FINAL PLAT


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS:

• THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER NEEDS TO MENTION THAT IT IS A RESUBDIVISION OF A PORTION OF BLOCK 4 OF DESERT HIGHLANDS ADDITION & THE MAP & PLAT OF THAT SUBDIVISON.
• THERE IS A 15’ ALLEY THAT RUNS BETWEEN LOTS 1-3 & LOTS 19-22 BELONGING TO THE CITY OF TUCSON PER ORDINANCE NO. 1391 IN DOCKET 630, PAGE 395. I CANNOT FIND ANYWHERE ON THE PLAT WHERE THE CITY IS DEDICATING OWNERSHIP OF THE ALLEY TO THIS SUBDIVISON.
• THE DEDICATION ON THE PLAT SHOWS OWNERSHIP TO BE FANELLI INVESTMENTS LLC & WALGREEN ARIZONA DRUG CO. OUR RECORDS SHOW THERE ARE ALSO OWNERS RUDOLPH E FUTER REVOC TR, THOMAS G & VIRGINIA E UNGER & RODRIGO BOJORQUEZ THAT I CANNOT LOCATE ANY DEED CONVEYING FROM THEM.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
03/15/2012 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S12-013
Walgreens & Pad A
Final Plat

TRANSMITTAL: 03/15/2012

DUE DATE: 03/20/2012

COMMENTS:


1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 03/04/2013. As of this final plat review date the tentative plat has not been approved therefore the one year date of the final plat approval is based on the date of submittal of the final plat documents. Once the tentative plat has been approved the approval date of the final plat will be on one year from the tentative plat approval date. This date will be provided on a future review of the final plat.

2. D 2-03.6.1.D.2 A small, project-location map will be drawn in the upper right corner of the first sheet of the plat at a scale of 3" = 1 mile. The location map shall provide the
following information.

2. Identify conditions within the square mile area, such as subdivisions, major
streets, major watercourses, and railroads. Reference recorded subdivision plats by book and page numbers.

3. DS 2-03.6.1.K The S12-013 subdivision case number assigned to this plat will be placed in the lower right corner of the plat next to the title block.

4. DS 2-03.6.2.D Revise general note #4 to read as follows: "This plat is subject to the conditions of rezoning case number C9-11-08, unless superseded by a subsequent rezoning ordinance."

5. DS 2-03.6.2.G Provide a general note as follows: "This plat is subject to Board of Adjustment variance C10-11-21, unless expired or superseded by a subsequent application."
Add the BOA case number near the lower right corner of all sheets.

6. DS 2-06.6 Per the conditional approval of the tentative plat, provide at the time of final plat, two copies of the CC&Rs, clearly indicating the cross vehicular access, pedestrian circulation access, maintenance of common vehicle use areas, and vehicle access for the two residential parcels (123-13-0750 and 123-13-0760). These documents have not been provided at the time of this review.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\finalplat\S12-013fp.doc
03/15/2012 LOREN MAKUS ENGINEERING REVIEW Denied March 15, 2012
S12-0013

The Final Plat cannot be approved as submitted. Please revise the following

1. Provide a complete location map as described in the development standard.
2. Include the name of the City Clerk in the approvals section. The current City Clerk is Roger Randolph.
3. Clarify the ownership information so the dedication and acknowledgment sections agree.

Loren Makus, EIT
Senior Engineering Associate
03/16/2012 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied Tucson Electric Power (TEP) has reviewed the final plat submitted March 5, 2012. TEP is unable to approve the plat at this time. There are existing electrical facilities within the boundaries of the plat. In order for TEP to approve the plat, the easements and recording information must be depicted on the final plat.

Costs associated with the removal or relocation of existing electrical facilities will be billable to the developer.

Please contact me at 917-8744 if you have any questions.

Thank you,

Mary Burke
Right of Way Agent
Tucson Electric Power Company
Mail Stop HQW603
PO Box 711
Tucson, AZ 85702
520-917-8744 Office
520-401-9895 Cell
mburke@tep.com
03/16/2012 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207


AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S12-013 WALGREENS AND PAD A/DEVELOPMENT PLAN – TENTATIVE PLAT
DATE: March 15, 2012



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

On the Final Plat delete E. from E. Edison Street and label Lot 1 on sheet 3.


Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
03/21/2012 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
03/21/2012 PGEHLEN1 COT NON-DSD REAL ESTATE Passed
03/21/2012 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

March 21, 2012

Jeff Behrana
Optimus Civil Design Group
4650 E. Cotton Center Blvd. # 200
Phoenix, AZ 85040

Subject: S12-013 WALGREENS PAD A Final Plat

Dear Jeff:

Your submittal of March 5, 2012 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 5 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Final Plat (Zoning, Engineering, TEP, Wastewater, PDSD)

3 Copies CC&R’s (Zoning, Engineering, PDSD)

1 Check Made out to “Pima County Treasurer” for $50.00 (Wastewater)

Should you have any questions, please call me at (520) 837-4893.

Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via Email: jbehrana@optimuscdg.com
03/21/2012 JWILLIA4 PIMA COUNTY WASTEWATER Denied PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


March 20, 2012

To: JEFF BEHRANA
OPTIMUS CIVIL DESIGN GROUP

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: AMIGOS DE ALPERT, LOTS 1 AND 2
Final Plat – 1st submittal
S12-013

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:
1. In the Dedication Block include reference, to hold harmless, Pima County Regional Wastewater Reclamation Department in servicing the public sewer on site.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.
The next submittal of this project will be the second(2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.
If the number of sheets changes, please adjust the review fee accordingly.

cc: Chad Amateau, PE Checked by:_________
Kristin Greene, PE, DLU Manager
DLU Project folder