Plan Number: S11-050
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S11-050
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/04/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/04/2011 FERNE RODRIGUEZ COT NON-DSD REAL ESTATE Passed
11/17/2011 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor’s Office


DATE: 11/17/11


RE: Assessor’s Review and Comments Regarding
S11-050 SORRENTO SQUARE RETAIL CENTER- FINAL PLAT


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS: THANK YOU FOR YOUR SUBMITTAL.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
11/23/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207

AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S11-050 SORRENTO SQUARE/FINAL PLAT
DATE: November 23, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1. On the Location Map change 22-91 to 28-91.
2. After each Common Area, include in parenthesis the uses.
11/30/2011 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied Re: Sorrento Square Retail Center - Final Plat
S11-050


Tucson Electric Power (TEP) has reviewed the final plat submitted November 7, 2011. TEP is unable to approve the plat at this time. In order for TEP to approve the final plat, all existing electrical easements must be identified on the plat.

Should you have any questions, please contact me at 917-8744.

Thank you,

Mary Burke
Associate Right of Way Agent
Tucson Electric Power Company
88 E. Broadway Blvd. 85701
Mail Stop HQW603
Tucson, AZ 85702
520-917-8744 Office
520-401-9895 Cell
mburke@tep.com
11/30/2011 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 11/30/2011,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Sorrento Square Retail Center
S11-050, T14S, R15E, SECTION 26

RECEIVED: Final Plat and Title Report on November 07, 2011

The subject project has been reviewed. The project can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that where made and references the exact location in the Final plat and in the Title Report where the revisions were made:

Final Plat:

1. Provide 2" margin on the left side and 1.5" margin on the remaining sides as required by D.S. 2-03.6.1.B.
2. Provide the complete S11-050 case number on every sheet (D.S. 2-03.6.1.K.).
3. Since the approved Tentative Plat/Development Plan does not have the proposed lot lines, submit a supplemental plan that shows the lot lines and all proposed improvements, including buildings, drainage facilities, parking areas, P.A.A.L's and easement, in order to clarify that the proposed lot lines and improvements will not be in conflict.
4. The gross area of the subdivision does not match the area shown on the approved Development Plan. Clarify the discrepancy (D.S. 2-03.6.2.A.).
5. Provide a general note which states: "A floodplain use permit is required for all improvements that are proposed within the areas that are affected by the regulatory floodplain (D.S. 2-03.6.2.E.).
6. Add the following general note: "Any relocation, modification, etc. of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public" (D.S. 2-03.6.2.I.).
7. Since the project does not appear to have private streets, remove any reference to private streets in the "Dedication" (D.S. 2-03.6.3.B.2.c).
8. It appears that the description of Common Area "C" is incorrect. Correct the description on both sheets.
9. It is not clear if assurances are required, for this subdivision, to assure the construction of the proposed infrastructure within the common areas. If assurances are submitted in the form of a "Third Party Land Trust", The "Beneficiary" Block must be added (D.S. 2-03.6.3.C.) and (D.S. 2-03.6.3.E.).
10. In the "Assurances" Block, replace "City of Tucson Engineer" by "City of Tucson Development Services Department Engineering Administrator" (D.S. 2-03.6.3.E.).
11. Is the company requesting the recordation of the plat called "The Architecture Company" or this is a generic name that needs to be replaced with the real name? (D.S. 2-03.6.3.D.).
12. Ensure that all applicable easements described in the Title Report are shown on the plat (D.S. 2-03.6.4.A.).
13. Show the required setbacks from the proposed detention/retention basins (D.S. 2-03.6.4.E.).
14. Show the detention/retention areas (within the common areas) in a surveyable and readily retraceable manner (D.S.2-03.6.4.I). Showing the survey information of the common areas within which there are detention/retention basins does not suffice.
15. In order to expedite the plat review and approval, provide the boundary survey and closure calculations report in accordance with D.S. 2-03.6.5.C.3.
16. Submit a copy of the project CC & R's. The CC & R's shall specifically address the maintenance of the drainage facilities. The CC & R's should include a paragraph, which addresses the maintenance of the drainage structures in details (i.e. what facilities to be inspected and maintained, how, when, by whom, the detention/retention basin maintenance list, keeping records, and repair decisions, etc). This Office also recommends including a Drainage Facilities maintenance checklist in the CC & R's to facilitate the Lot Owners Association maintenance responsibilities (D.S.2-03.6.6.).


RESUBMITTAL REQUIRED: Revised Final Plat, CC & R's, and Assurances
12/05/2011 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S11-050
Sorrento Square Retail Center
Final Plat

TRANSMITTAL: 12/05/2011

DUE DATE: 12/07/2011

COMMENTS:


1. An applicant has three (3) years from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 9/07/2013.

2. Provide a reference set of plans clearly indicating the location of all buildings, drainage basins, vehicle use areas, etc. in relation to the proposed property lines.

3. DS 2-03.6.1.K This project has been assigned case number S11-050. Place this number near the lower right corner of all sheets.

4. DS 2-03.6.2.A General note number 1 indicates a different gross area than shown on the last approved Development Plan. Clarify.

5. DS 2-03.6.6 Provide a copy of the recorded CC&Rs indicating maintenance for common areas, cross access, cross parking agreements, etc.

6. DS 2-03.6.3.D In the blank for the approval portion of the final plat, place the city clerks name, Roger W. Randolph.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\finalplat\S11-050fp.doc
12/08/2011 JWILLIA4 PIMA COUNTY WASTEWATER Denied PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135

December 8, 2011


To: Kevin Hall, Project Manager
Cypress Civil Development

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Kristin L. Greene, P.E., CE Manager
RWRD, Development Review Manager

Subject: Sorrento Square Retail Center
Lots 1 through 10 & Common Areas A, B & C
Final Plat - 1st Submittal, S11-050, review comments



The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The PDEQ and the PCRWRD hereby reject the above referenced submittal of the Final Plat as received by us on October 11, 2011, for the following reasons:

1. All sheets, Title Block: Boldly show the entire project case number, adjacent to the Title block.

2. Sheets 1 and 2: Revise the Area map and the Final Plat so that they show the existing Public Sewer Easement. Where appropriate show easement dimensions and recording information.

3. Revise the Dedication block, second paragraph, first sentence, so that: …COMMON AREAS… ARE GRANTED (or dedicated) AS EASEMENTS TO CITY OF TUCSON, PIMA COUNTY AND UTILITY COMPANIES…


4. Project has not been sealed by RLS or PE.

The next submittal will be the second submittal for this Final Plat. The RWRD review fee for the second submittal will be $100.00 (Per PC Code, Title 13.20.030.A.2). Please let me know if you have any questions.




Kristin L. Greene, P.E.
Civil Engineering Manager, Development Liaison Unit

































Cc: Chad Amateau, P.E., RWRD
Chandubhai Patel, P.E., RWRD
Robert E. Flynt, PC DSD
Project file
12/08/2011 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
12/09/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

December 9, 2011

Kevin Hall
Cypress Civil Development
2102 N. Country Club # 9
Tucson, Arizona 85716

Subject: S11-050 SORRENTO SQUARE RETAIL CENTER Final Plat

Dear Kevin:

Your submittal of November 4, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 6 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

6 Copies Revised Final Plat (Addressing, TEP, Engineering, Zoning, Wastewater, PDSD)

2 Copies Assurances Package (Engineering, PDSD)

3 Copies CC&R’s (Zoning, Engineering, PDSD)

2 Copies Boundary Survey & Closure Calculations (Engineering, PDSD)

1 Check Made out to “Pima County Treasurer” for $100.00 (Wastewater)

Should you have any questions, please call me at 837-4893.

Sincerely,



John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (520) 296-1571