Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S11-048
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/19/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/19/2011 | PGEHLEN1 | COT NON-DSD | REAL ESTATE | Approved | per e-mail from Jim Rossi |
| 12/19/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: December 19, 2011 SUBJECT: The Retreat Final Plat Submittal- 3rd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 920 E 22nd Street, T14S R14E Sec19 Ward 5 REVIEWER: Jason Green, CFM ACTIVITY: S11-048 SUMMARY: Engineering Division of Planning and Development Services Department has received, Sheets 1 and 2 of the proposed Final Plat and a copy of the Title Report. Engineering Division has reviewed the submitted Final Plat and Title Report and recommends approval of the Final Plat at this time. GENERAL COMMENTS: Provide a Final Plat Mylar for final CDRC approval. For questions I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Planning & Development Services |
| 12/19/2011 | JWILLIA4 | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 December 19, 2011 To: Dan Castro, Project Manager RICK ENGINEERING COMPANY Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Kristin L. Greene, P.E., Civil Eng. Manager RWRD, Development Review Manager Subject: The Retreat, Block 1 Final Plat – 2nd Submittal, S11-048, review comments The drawings of the Final Plat for the proposed project have been reviewed on behalf of Pima County Department of Environmental Quality (PDEQ) and Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to either Department. The following comments are offered. The PCRWRD hereby approves the above referenced submittal of the Final Plat received by us on November 7, 2011. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) will need to be obtained from PDEQ. Also, air quality activity permits must be secured by the developer or prime contractor from PDEQ before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Kristin L. Greene, P.E. Civil Engineering Manager, Development Liaison Unit Cc: Chad Amateau, P.E., RWRD Chandubhai Patel, P.E., RWRD Project file |
| 12/20/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES December 20, 2011 Dan Castro Rick Engineering Company, Inc. 3945 E. Fort Lowell Rd. #111 Tucson, Arizona 85712 Subject: S11-048 THE RETREAT Final Plat Dear Dan: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents: 1 Executed Final Plat Double Matte Océ or Photo Mylar. 2 Title reports current within the last thirty (30) days. 1 Check made payable to “Pima County Recorder” in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page and fees for consent(s) to dedicate, if applicable. 1 Original Set of Executed and notarized CC&R’s document (if applicable) and Assurance Package (if applicable). 1 Copied Set of Executed and notarized CC&R’s document (if applicable) and Assurance Package (if applicable). 1 CD with Digital Copy in PDF Format of Plat, CC&R’s (if applicable) and Assurances (if applicable). Assurances (if applicable) must be reviewed by the City Attorney’s Office prior to being presented to the Mayor and Council. Plats, CC&R’s and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval. Should you have any questions, please call me at (520) 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 322-6956 |