Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S11-048
Parcel: Unknown

Address:
1000 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S11-048
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2011 JWILLIA4 START PLANS SUBMITTED Completed
11/17/2011 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor's Office


DATE: 11/17/11


RE: Assessor's Review and Comments Regarding
S11-048 THE RETREAT: RESUBMITTAL- FINAL PLAT


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.

COMMENTS: THANK YOU FOR YOUR SUBMITTAL.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
11/21/2011 JASON GREEN ENGINEERING REVIEW Approv-Cond DATE: November 21, 2011
SUBJECT: The Retreat Final Plat Submittal- 2nd Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 920 E 22nd Street, T14S R14E Sec19 Ward 5
REVIEWER: Jason Green, CFM
ACTIVITY: S11-048

SUMMARY: Engineering Division of Planning and Development Services Department has received, Sheets 1 and 2 of the proposed Final Plat and a copy of the Title Report. Engineering Division has reviewed the submitted Final Plat and Title Report and recommends conditional approval of the Final Plat at this time. The following items need to be addressed prior to final Mylar approval:


FINAL PLAT COMMENTS:

1) Completed.
2) Completed.
3) Completed.
4) Completed.

5) Restated: DS Sec.2-03.6.4.A: It is acknowledged that a lease agreement is proposed for the billboard lease area and ingress/egress however at a minimum the lease area for the billboard must be shown in plan view on the final plat prior to final plat Mylar approval.

6) Completed.

7) Restated: DS Sec.2-03.6.4.A: Provide recordation information for all proposed vacated easements per the submitted Easement release form and as stated in the comment letter prior to final plat Mylar approval.

8) Completed.
9) Completed.
10) Acknowledged. Subject to Landscape Approval.
11) Completed.
12) Acknowledged.


GENERAL COMMENTS:

Provide a Final Plat Mylar at re-submittal addressing the 2 outstanding comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For questions or to schedule a meeting I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
11/22/2011 DAVID RIVERA ZONING REVIEW Approved
11/22/2011 FERNE RODRIGUEZ PIMA COUNTY ADDRESSING Approved AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S11-048 THE RETREAT/ REVISED FINAL PLAT
DATE: November 18, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
12/05/2011 JWILLIA4 PIMA COUNTY WASTEWATER Denied PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135
December 2, 2011


To: Dan Castro, Project Manager
RICK ENGINEERING COMPANY

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Kristin L. Greene, P.E., Civil Eng. Manager
RWRD, Development Review Manager

Subject: The Retreat, Block 1
Final Plat – 2nd Submittal, S11-048, review comments



The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The PDEQ and the PCRWRD hereby reject the above referenced submittal of the Final Plat as received by us on October 11, 2011, for the following reasons:

1. Item #4, from the review letter dated October 27, 2011, has not been adequately addressed. “RWRD has an active sanitary sewer in the 23rd Street right-of-way. Provide the recording information for the vacation (release) of this public asset. Per Bill Knight, Program Manager’s letter to Mr. Rossi, dated February 18, 2011, RWRD retains an easement over the public sewer line (see attached). Revise the plat as appropriate.”

• Show an existing public sewer easement in the vacated right-of-way for 23rd Street, or dedicate an easement over existing sewer G-253, by this plat.

• Label the portion of the easement that will be released or vacated with a label that read something like:
“To be Vacated by Separate Instrument,” with a “Sequence # ___________’ line.

Questions about release or vacation of existing easements, over active public sewers, should be directed to Mr. Steven Reuter, Program Manager, RWRD Real Property/Environmental/Cultural Resources. Steven may be reached by phone at (520) 740-6608, or via email at steven.reuter@pima.gov

The next submittal will be the second submittal for this Final Plat. The RWRD review fee for the third submittal will be $39.00 (Per PC Code, Title 13.20.030.A.2).

Please let me know if you have any questions.




Kristin L. Greene, P.E.
Civil Engineering Manager, Development Liaison Unit


























Cc: Chad Amateau, P.E., RWRD
Chandubhai Patel, P.E., RWRD
Project file
12/06/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

December 6, 2011

Dan Castro
Rick Engineering Company, Inc.
3945 E. Fort Lowell Rd. #111
Tucson, Arizona 85712

Subject: S11-048 THE RETREAT Final Plat

Dear Dan:

Your submittal of October 11, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Final Plat (Wastewater, Engineering, PDSD)

1 Check Made out to “Pima County Treasurer” for $39 (Wastewater)

Should you have any questions, please call me at 837-4893.

Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 322-6956