Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: S11-044
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - TENT PLAT & CORE RESUB

Plan Number - S11-044
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/20/2015 EGALLET1 START PLANS SUBMITTED Completed
11/27/2015 MARTIN BROWN FIRE REVIEW Reqs Change Please include site plan indicating location(s) of existing and/or proposed fire hydrants
12/03/2015 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: S11-044 (revision)
9250 S Houghton Road
Houghton Town Center - Tentative Plat
(revised sheets 1, 2, 4, 5, 8, 8A, 11A, 12, 13, 13A, and L1, L4, L5, L8, L9, L25, L27, L29, L30)

TRANSMITTAL DATE: December 3, 2015

DUE DATE: December 7, 2015

COMMENTS: Address the following zoning comments and resubmit for review. The comments are based on the revision cover letter submitted with the revised TP. The comments are based on comparison of the last revision TP on file with PDSD.

COMMENT 01 - S11-044 shall be updated with all new development proposals in order have the current information for the overall development. It is acknowledged that your firm has not produced all the documents for all of the proposed developments in the HTC but it is fair to say that the S11-044 document is updated by your firm and should depict all developments and calculations accordingly.

COMMENT 02 - The following comments are related to sheet 8.

a. On sheet 8, the location of the short term bicycle parking facilities could not be verified. Review the plan for location and add and label the short term facilities for the Food Service building on lot 24. Add to the keynotes that the short term facilities are within 50 feet of the main entrance or add the dimension from the facility to the main entrances of all buildings depicted on sheet 8.

b. There are two key notes locations with the number 15 that need to be revised. One is noted as a ramp key note but the leader arrow is not pointing to the ramp the keynote 15 is point to a sidewalk. The keynote with the number 15 circled in green on lot 29 along the northwest corner of the building that is supposed to be pointing to an accessible ramp does not appear to match the other two accessible ramps that include the same keynote 15. On lot 26 the keynote with the number 15 is pointing to an accessible ramp that also does not match the other ramps. Revise as required with the correct keynotes that include the correct detail drawing. (The detail sheet was not included in the package so it is not clear if the detail drawings match the keynote callouts or if the details drawing have been revised to match the locations.

c. Keynote number 16 on sheet 8 that is located across from the retail building on lot 26 notes that a ramp is proposed in the HC access aisle. The drawing must be revised to provide a ramp with the sidewalk and not in the assess aisle. Revise as required. (key note is circled in green.)

d. A sidewalk must be provided to the dumpster location next to building on lot 27.
Add a dimension between the long term bicycle facility and the southeast corner of the building on lot 27. The minimum width required is 4 feet.

e. Keynote number 22 could be verified on sheet 8. Clarify which accessible ramp was to be annotated with keynote 22.

f. I believe that the FFE of 34 feet labeled for the buildings on lots 27, 28, and 29 is a typo. Provide the correct FFE for these buildings.

03. Sheet 8A - The dimensions on the property lines do not seem to be accurate. In using the 50 scale to verify distance information labeled for the property lines, it was noted that several of the dimensions are incorrect. Review the survey information and revise the lot line distance information that is incorrect on Sheet 8A. if the distance labeled on sheet 8A were used to verify the lot areas double check the lot areas for accuracy.

04. Sheet 11A - Clarify if all the uses listed on sheet 11A include along with the existing uses all current development proposals under PDSD review.

05. Sheet L5 - After reviewing the sheet L-5 and consulting with the landscaper plans reviewer it has been noted that there does not appear to be sufficient vegetation to create a 30 inch opaque screen in front of the lot 24 Food Service Drive-through facing Houghton Road. Contact Andrew Connor about the screening materials to screen to the drive-through lane.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Site Plan and Landscape plans
12/03/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Clarify the first floor elevations for the buildings on lots 27, 28, and 29. On sheet 5 the first floor elevations are 12.00' but on sheet 8 the first floor elevations are shown as 34.00'. Considering that the existing contours run from 3009' to 3013' in the building pad area, a first floor elevation of 3034' could cause an accessibility issue.
12/07/2015 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Ensure that all Zoning and Engineering comments and concerns are addressed prior to Landscape approval.
12/07/2015 LOREN MAKUS ENGINEERING REVIEW Approv-Cond The revision is approved on the condition the floor elevations are corrected to be consistent with the adjacent grades.
12/07/2015 DAVID RIVERA H/C SITE REVIEW Reqs Change see zoning comments
12/08/2015 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) 2 rolled sets of the plans
2) All items requested by review staff
3) All items needed to approved this plan

Final Status

Task End Date Reviewer's Name Type of Review Description
12/08/2015 AROMERO4 OUT TO CUSTOMER Completed