Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S11-043
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/06/2013 | CPIERCE1 | START | PLANS SUBMITTED | Completed | |
| 05/07/2013 | PGEHLEN1 | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 May 7, 2013 To: PAT MARUM WOOD PATEL & ASSOCIATES Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________________ From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department Subject: THE BRIDGES--BLOCK 10; LOTS 1-84; BLOCKS "A" AND "B" & COM- MON AREAS "A", "B", "C" Development Plan - 3rd Submittal S11-043 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the Site Plan as received by us on May7, 2013. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. If you have any questions about this review letter please call me @ the phone number above. |
| 05/14/2013 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: S11-043 The Bridges - Block 10 Tentative Plat (3rd Review) TRANSMITTAL DATE: May 14, 2013 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements. 2. D.S. 2-03.1.E Zoning acknowledges this comment should have been made on an earlier review. Please revise the sheet number X of Y to include the total number of sheet 14. 3. All calculations on sheet 2, "TRACKING TABLE FOR THE BRIDGES PAD - 15" need to reflect the last approved development package Dp12-0113> If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat. |
| 05/17/2013 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Approved | |
| 05/31/2013 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | DATE: May 31, 2013 TO: Patricia Gehlen; CDRC Coordinator FOR: Pat Marum, P.E., Wood Patel Engineering SUBJECT: The Bridges Block 10 Tentative Plat 2nd Re-submittal Engineering Review LOCATION: T14S R14E Section 30 REVIEWER: Elizabeth Leibold CASE NUMBER: S11-043 SUMMARY: Engineering has reviewed the resubmitted development package for the Tentative Plat and other documents, and recommends approval of the Tentative Plat. Please be aware that per Technical Standard 11-01.4, if easements are relocated, not in use, or proposed for abandonment, then the documentation of the vacation/abandonment/relocation shall be submitted prior to approval of Final Plat. The request for abandonment of the utility easements as indicated should be made to the entity holding an easement interest shortly after the City Development Review Committee (CDRC) approval of the tentative plat. Schedule B Item 18 (2011-2440170) was not found on the Tentative Plat, and the following easements on this submittal of the Tentative Plat were not found on the Title Report and will need to be addressed at Final Plat review stage: a) Dkt.107-pg.588 Re. 2013-1210195 b) Dkt.638-pg.32 Re. 8281-2493 c) Dkt.1671-pg.177 Re. 2012-2790064 d) Dkt.2048-pg.562 Re. 8281-2491 e) Dkt.2182-pg.307 Re. 2012-2790065 f) Dkt.7894-pg.1024 Re. 2012-2790063 If you have any questions, please call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services |
| 06/03/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | Once revised sheets have been submitted to address the conditions of approval, the plans will be signed. In addition to the revised sheets, please submit all items (documents, reports etc) used to approve these plans. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/10/2013 | CPIERCE1 | REJECT SHELF | Completed |
| 06/10/2013 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |