Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - CONDO CONVERSION
Plan Number - S11-042
Review Name: FINAL PLAT - CONDO CONVERSION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/30/2011 | DAVID MANN | COT NON-DSD | FIRE | Approved | |
| 09/08/2011 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Denied | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Sherry Hyde Senior Property Technician Pima County Assessor’s Office DATE: 9/6/11 RE: Assessor’s Review and Comments Regarding S11-042 WAREHOUSE BREWERY CONDOMINIUMS: FINAL PLAT- CONDO CONVERSION * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor’s Office requirements. ___X___ Plat does not meet Assessor’s Office requirements. COMMENTS: THERE MUST ME A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION. THE TITLE BLOCK STATES COMMON ELEMENT A AS PARKING AREAS & ENTRY DRIVES, BUT THE DRAWING APPEARS TO SHOW THE DRIVE AREA AS COMMON AREA B. IT APPEARS THAT COMMON ELEMENT A & IN THE DRAWING IS THE WALKS, ENTRIES… I CANNOT FIND THE LIMITED COMMON ELEMENT “A” LISTED ON THE DRAWING. THE SQUARE FOOTAGE FOR COMMON ELEMENT A & B NEEDS TO BE LISTED. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 09/21/2011 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: WAREHOUSE BREWERY CONDOMINIUMS S11-042 Tucson Electric Power Co. (TEP) approves the final plat submitted for review August 29, 2011. Any easements required to serve this project will be secured by separate instrument. Please forward any resubmittals of the final plat to this office. Feel free to contact me at (520)917-8744 if you have any questions. Thank you, Mary Burke Associate Right of Way Agent Tucson Electric Power Company 4350 E. Irvington Road Mail Stop DS315 Tucson, AZ 85714 520-917-8744 Office 520-401-9895 Cell mburke@tep.com |
| 09/21/2011 | RONALD BROWN | H/C SITE | REVIEW | Denied | Need to show parking layout, accessible parking and accessible route from parking to accessible entry of building and to Broadway right of way. |
| 09/21/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. As per table 602 of the 2006 IBC, all building walls within 10' of the property line must be 1 hour fire rated. 2. Need to show parking layout, accessible parking and accessible route from parking to accessible entry of building and to Broadway right of way. |
| 09/26/2011 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: S11-042 WAREHOUSE BREWERY CONDOMINIUMS/FINAL PLAT DATE: September 23, 2011 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through Pima County Addressing. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 09/28/2011 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S11-042 Warehouse Brewery Condominiums Final Plat TRANSMITTAL: 09/28/2011 DUE DATE: 09/28/2011 COMMENTS: 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a final plat. If, at the end of that time, the final plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this final plat is 08/28/2012. 2. DS 2-03.6.1.K This project has been assigned case number S11-042. Place this number near the lower right corner of all sheets. 3. DS 2-03.6.2.A Revise general note #2 to read as follows: The gross area of this subdivision is 0.56 acres. 4. Label the elevation sheet as reference only for building heights. FYI: It appears that changes to the exterior of the building are proposed. A separate site plan submittal will be required with approval from the Development Review Board (DRB). Contact Russlyn Wells (837-4948) for further information on DRB procedures. 5. Review LUC Sec. 4.1.9.2 and comply by providing the required report. 6. Provide cross sections of each unit and provide a table clearly indicating the cubic volume of each unit. See Engineering comments. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\finalplat\S11-042fp.doc |
| 09/28/2011 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | September 28, 2011 D11-042 Warehouse Brewery Condominiums Plat Review The plat cannot be approved as submitted. Please revise the following items: 1. The description of the common elements in the title block doesn't match the graphical depictions on the plat. Revise the plat to be consistent. 2. At least one (1) corner of the subdivision must be tied by course and distance to a section corner, a quarter section corner, or an established City or County survey monument. The plat must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plat. 3. Revise the Declaration of Covenants, Conditions and Restriction to correct the spelling of restaurant, where it is misspelled in several places. 4. Revise exhibit C to account for 100%. 5. Provide building and unit cross-sections and analysis showing volumes of each unit. |
| 09/29/2011 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | |
| 09/29/2011 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | September 29, 2011 To: LINDA THOMPSON, WLB Group Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department From: Chandubhai C Patel, P.E., Civil Eng. Manager Development Review Division Subject: WAREHOUSE BREWERY CONDOMINIUMS Units 1, 2 and 3, Limited Common Element “A” and Common Elements “A” and “B” Final Plat - 1st Submittal, S11-042 The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and the Regional Wastewater Reclamation Department hereby approve the above referenced submittal of the Final Plat as received by us on August 29, 2011. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. Please let me know if you have any questions. |
| 09/30/2011 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES September 30, 2011 Jack Buchanan The WLB Group, Inc. 4444 East Broadway Blvd. Tucson, Arizona 85711 Subject: S11-042 Warehouse Brewery Condos Final Plat Dear Jack: Your submittal of 8/29/2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 6 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Final Plat (Assessor, Building, ADA, Engineering, Zoning, PDSD) 2 Copies Revised CC&R's (Engineering, PDSD) Should you have any questions, please call me at (520) 837-4919. Sincerely, Patricia Gehlen Project Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 881-7480 |