Plan Number: S11-037
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - FINAL PLAT REVIEW

Plan Number - S11-037
Review Name: REVISION - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/29/2011 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 08/08/2011,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Sierra Morado Unit 2 West
S11-037, Formerly S05-088, T15S, R15E, SECTION 12

RECEIVED: Revised Final Plat on July 28, 2011

The subject project has been reviewed. The proposed revisions are acceptable; however the Final Plat can not be approved at this time. Address the following comments before the next submittal:

1. The revised Tentative Plat has not been approved by several agencies. Since the Final Plat might change as a result of the denial comments, it can not be recommended for approval, by Engineering and Floodplain Review, at this time.
2. The submitted title report appears to have legal and easement descriptions that are not applicable to the submitted final plat and the new lots shown on it. Clarify.
3. The easement proposed to be abandoned shall be either abandoned by the plat or the abandonment shall be processed and the recordation information shall be shown on the final plat.
4. Revise all reference to the "Development Services Department" to read "Planning and Development Services Department". Revise the first sheet accordingly.
5. Revise the "City of Tucson Engineer" signature line to read "City of Tucson Planning and Development Services Engineering Administrator".


RESUBMITTAL REQUIRED: Revised Final Plat and Title Report
08/04/2011 MICHAEL ST. PAUL ZONING REVIEW Approv-Cond CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
S11-037 (S11-039)
Sierra Morado Unit 2 Resubdivision
Final Plat; 1st review


TRANSMITTAL: August 4, 2011


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


Provide the case number (S11-037) in the lower right corner of each sheet of the final plat (DS 2-03.6.1.K).

The Final Plat shall be approved with the Tentative Plat approval.
08/04/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S11-037 SIERRA MORADO UNIT 2 WEST/FINAL PLAT
DATE: August 4, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
08/08/2011 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor’s Office


DATE: 8/4/11


RE: Assessor’s Review and Comments Regarding
S11-037 SIERRA MORADO UNIT 2 WEST


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS: THANK YOU FOR YOUR SUBMITTAL

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
08/09/2011 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
08/09/2011 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: SIERRA MORADO, UNIT 2 REVISION
S11-037

Tucson Electric Power Company (TEP) has reviewed the final plat submitted July 28, 2011 and approves the plat.

There are existing electrical facilities within the boundaries of the lot revisions. All relocation costs will be billable to the developer.

TEP will determine which existing facilities will remain and those that will be removed a preliminary electrical design for the lot revisions will be provided within twenty-five (25) working days upon receipt of the Approved Tentative plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Also, submit the AutoCAD version of the plat on a CD or email to mburke@tep.com<mailto:mburke@tep.com>. Should you have any questions, please contact me at (520) 917-8745 or Mary Burke at (520) 917-8744.

Liza Castillo
Right of Way Agent II
Tucson Electric Power Co.
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com<mailto:lcastillo@tep.com>
08/22/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

August 22, 2011

Warren Thompson P.E.
Stantec Consulting
201 N. Bonita Ave. # 101
Tucson, Arizona 85745

Subject: S11-037 SIERRA MORADO UNIT 2 REVISION Final Plat

Dear Warren:

Your submittal of July 28, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 2 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Final Plat (Engineering, PDSD)

2 Copies Revised Title Report (Engineering, PDSD)


Should you have any questions, please call me at 837-4893.

Sincerely,





John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 750-7470
08/22/2011 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Approved August 19, 2011

To: Warren D. Thompson, P.E.
Stantec Consulting

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C Patel, P.E., Civil Eng. Manager
Development Review Division ( Wastewater)

Subject: SIERRA MORADO, UNIT 2 WEST (Replat)
Lots 1531 through 1546 and Common Areas “A” and “B”, S11-037


The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The PDEQ and the PCRWRD hereby approve the above referenced submittal of the Final Plat received by us on July 28, 2011.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above comments, please do not hesitate to contact me.