Plan Review Detail
Review Status: Completed
Review Details: REVISION - TENT PLAT & CORE RESUB
Plan Number - S11-037
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/25/2011 | RONALD BROWN | H/C SITE | REVIEW | Approved | |
| 07/26/2011 | DAVID MANN | COT NON-DSD | FIRE | Denied | Fire Comments: The Note 29 from the original plans: "Fire Hydrants Shall be Provided..." remains but some areas show hydrants and others do not. Put on all the hydrants or take them off. As currently shown most areas do not comply with the old or new fire codes. Final hydrant locations will be on the water plan. Some of the lots are now large enough to have a 3600 square foot roof coverage. That would require a 1750 gallon per minute water supply, not the 1000 on the original note 33. |
| 07/27/2011 | FERNE RODRIGUEZ | PIMA COUNTY | ADDRESSING | Denied | AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: S11-037 SIERRA MORADO UNIT 2/TENTATIVE PLAT DATE: July 27, 2011 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Correct all the street suffixes for: a. Change Tiger Lily Lane to Place. b. Change Saguaro Sunset Drive to Place. c. Change Bryony Street to Lane. |
| 07/27/2011 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | >>> Zelin Canchola 07/27/2011 10:02 AM >>> Approved as shown on plan. |
| 08/01/2011 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Denied | DEPARTMENT OF PLANNING & DEVELOPMENT SERVICES Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S11-037 (Revision) Sierra Morado 7/27/11 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: S05-088 NEIGHBORHOOD PLAN: Civano PAD GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: 8/8/11 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: REVIEWER: Jbeall 837-6966 DATE: 7/27/11 Comments 1. Please provide a note to the General Notes, Sheet 1 of 14, which reads: ‘This plat is designed to meet the criteria within Sierra Morado, where at least 65 percent of the residential lots will incorporate one of the garage design treatments as found in Figures 22 and 22A of the Civano PAD.’ 2. Please attach a copy of the PDSD determination letter for the minor amendment of the Civano PAD, Sierra Morado, D-3.d Garage Treatment, Figure 22. (A copy of this letter will also need to be attached to the revision for Sierra Morado Unit 4). |
| 08/03/2011 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Denied | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 July 29, 2011 To: WARREN D. THOMPSON STANTEC CONSULTING Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________________ From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department Subject: SIERRA MORADO UNIT 2, LOTS 228-472, 506-722, 765-806, & 1531-1588; BLOCK "A", BLOCK "B"; COMMON AREA "A", "B" & "C" Tentative Plat – 2nd Submittal S11-037 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: Sheets 3-11: The sewer shown as proposed on plan has been built and accepted by the County. Please include a note on each sheet which refers to the public sewer on the plan as existing per the appropriate construction plan # with associated lot numbers.(Ref B) Sheets 10: Include a note which indicates that HCS connections will be made separately for each lot at 90 degrees to the street fronting property line. (Ref D, F, H and I) Sheet 10: Along Tiger Lilly Lane, show on plan the existing private sewer lines called out as to be abandoned and stubbed at the property line. (Ref D,F,H and I) This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second(2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. cc: Chad Amateau, PE Checked by:_________ Kristin Greene, PE, DLU Manager DLU Project folder Ref. B. - Tentative Plat Requirements – Chapter 18.69 of the Pima County Code – Section I http://www.pimaxpress.com/SubDivision/PDFs/2007/TentativePlatReview.pdf Ref. C - Arizona Administrative Code, Title 18, Chapters 5 & 9 (R18-5-205) http://www.azsos.gov/public_services/Title_18/18-05.htm and (R-18-9-E301) http://www.azsos.gov/public_services/Title_18/18-09.htm Ref. D - PCRWRD Procedures, Preliminary Sewer Layout Requirements, 1984 (revised April 1988) http://www.pima.gov/wwm/eng/stddet/pdf/procedures.pdf Ref. F - City of Tucson/Pima County Standard Details http://www.pima.gov/wwm/eng/stddet/pdf/all_det.pdf Ref. G - Pima County Code of Ordinances, Title 13 - Public Services, Division II - Sewers http://library.municode.com/index.aspx?clientID=16119&stateID=3&statename=Arizona Ref. H - City of Tucson/Pima County Standard Specifications for Public Improvements, 2003 Edition http://dot.pima.gov/transeng/stdspecsdet/standardspecs2003.pdf Ref. I - PCRWRD Engineering Directives http://www.pima.gov/wwm/eng/directives/ |
| 08/04/2011 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | Laith Alshami, Engineering and Flooplain Review, 08/04/2011, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Sierra Morado Unit 2 S11-037, Formerly S05-088, T15S, R15E, SECTION 12 RECEIVED: Revised Tentative Plat on July 28, 2011 The subject project has been reviewed. The proposed revisions are acceptable. The revised Tentative Plat is acceptable and recommended for conditional approval subject to adding the new S11-037 on the cover sheet. |
| 08/04/2011 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: S11-037 (S11-039) Sierra Morado Unit 2 Resubdivision Tentative Plat; 1st review TRANSMITTAL: August 4, 2011 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is July 25, 2011. Provide the new subdivision case number S11-037 for Sierra Morado, Unit 2 West and refer to S11-039 for Sierra Morado, Unit 2 East in the lower right corner of the plant next to the title block with all the other CDRC references (DS 2-03.2.2.B.1). There are no further comments at this time. |
| 08/05/2011 | FERNE RODRIGUEZ | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: SIERRA MORADO, UNIT 2 REVISION S11-037 Tucson Electric Power Company (TEP) has reviewed the tentative plat submitted July 25, 2011 and approves the plat. There are existing electrical facilities within the boundaries of the lot revisions. All relocation costs will be billable to the developer. TEP will determine which existing facilities will remain and those that will be removed a preliminary electrical design for the lot revisions will be provided within twenty-five (25) working days upon receipt of the Approved Tentative plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Also, submit the AutoCAD version of the plat on a CD or email to mburke@tep.com<mailto:mburke@tep.com>. Should you have any questions, please contact me at (520) 917-8745 or Mary Burke at (520) 917-8744. Liza Castillo Right of Way Agent II Tucson Electric Power Co. offc-(520) 917-8745 fax-(520) 545-1416 lcastillo@tep.com<mailto:lcastillo@tep.com> |
| 08/08/2011 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 08/09/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES August 9, 2011 Warren Thompson Stantec Consulting 201 N. Bonita Ave. # 101 Tucson, Arizona 85745 Subject: S11-037 SIERRA MORADO UNIT 2 Tentative Plat Dear Warren: Your submittal of July 22, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 8 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 8 Copies Revised Tentative Plat (HC Site, Fire, Addressing, Planning, Wastewater, Engineering, Zoning, PDSD) 4 Copies Revised Landscape Plan (Planning, Engineering, Zoning, PDSD) 2 Copies PDSD Determination Letter for the Minor Amendment of Civano PAD (Planning, PDSD) 1 Check Made out to “Pima County Treasurer” for $100 (Wastewater) Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/ Via fax: 750-7470 |
| 08/09/2011 | FRODRIG2 | ENV SVCS | REVIEW | Approved | Date Case Number Project Address August 8, 2011 S11-037 Sierra Mora do Unit 2 Replat Tentative Plat Comments: The proposed Tentative Plat for the Sierra Morado Unit-2 Replat Case No. S11-037, meets the minimum requirements for the Environmental Services, Solid Waste Disposal Standard 6-01.0 and is here Approved, Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |