Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S11-014
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S11-014
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/26/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/26/2011 FERNE RODRIGUEZ COT NON-DSD REAL ESTATE Passed
04/29/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S11-014 BUSINESS PARK OF THE DESERT/FINAL PLAT
DATE: April 29, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
05/05/2011 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor’s Office


DATE: May 5, 2011


RE: Assessor’s Review and Comments Regarding
S11-014 BUSINESS PARK OF THE DESERT- FINAL PLAT


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS: THANK YOU FOR YOUR SUBMITTAL.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
05/13/2011 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#236716 May 13, 2011

Dear Mr. Castro:

SUBJECT: BUSINESS PARK OF THE DESERT
S11-014


Tucson Electric Power Company has reviewed and disapproved the development plan submitted May 11, 2011. It appears that there are conflicts with the existing facilities within the boundaries of this proposed development. Please show facilities on the plan. A facilities map is attached for reference. Existing equipment is located within proposed Pedestrian Access Easement. No structures or buildings may be placed on top of existing stubs or equipment. Conflicts can not be determined until facilities are properly indicated on the plan. Customer will be responsible for relocation costs and a new route for existing stubs. New easements may be required for relocation.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Please call the area Designer Jessica Marchbanks at (520) 917-8737, should you have any questions.

Sincerely,


Henrietta Noriega
Office Specialist
Design/Build
hn
Enclosures
Cc J.Marchbanks, Tucson Electric Power
DSD, City of Tucson (E-Mail)
05/24/2011 JWILLIA4 PIMA COUNTY WASTEWATER Denied May 24, 2011

To: Dan Castro
Rick Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C Patel, P.E., Civil Eng. Manager
Development Review Division (Wastewater)

Subject: Business Park of The Desert, Lots 1, 2 & 3 and Common Areas "A"
A Resubdivision of the Phase I Condominiums, S11-014


The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The 1.General: A Site Plan is required showing the existing and proposed sewers, point and method of connection, access, etc. for Lots 1 & 2.

The Final Plat cannot be approved without first reviewing and approving the site plan.

2. Sheet 2: The extent and location of the 20-foot R/W is not clear. Please clarify by showing the R/W boundaries and properly pointing the arrow.

3. Please do not resubmit this Final Plat until the Site Plan gets approved.

4. All sheets: Show this project number S11-014 in the Title Block.

5. All sheets: Show the approved Site Plan number as a reference number near the Title Block.

6. The next submittal will need a review fee of $ 50.00.

If you have any questions regarding the above comments, please do not hesitate to contact me.
05/24/2011 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S11-014
Business Park of the Desert
Final Plat

TRANSMITTAL: 05/24/2011

DUE DATE: 05/24/11

COMMENTS:


1. An applicant has one (1) year from the date of submittal to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 04/27/12.

2. DS 2-03.6.1.K this project has been assigned case number S11-014. Place this number near the lower right corner of all sheets.

3. Provide a copy of the approved site plan clearly indicating the proposed new lot line in order to verify location of the new lot line in relation to the proposed buildings.

4. Provide a revised copy of the CC&Rs with the number of lots (revise cover sheet to match cover sheet of plan) and revise the body of the document, in the CC&Rs cross access and if required cross parking will be required to be provided between Lot 1 and Lot 2.

5. DS 2-03.6.2.H Add the following note: "There will be no further division of lots without the expressed approval of the City of Tucson."

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961


TLS C:\planning\cdrc\finalplat\S11-014fp.doc
05/25/2011 JASON GREEN ENGINEERING REVIEW Denied DATE: May 24, 2011
SUBJECT: Business Park of the Desert Final Plat Submittal- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 7000 S Palo Verde Road, T15S R14E Sec16 Ward 5
REVIEWER: Jason Green, CFM
ACTIVITY: S11-014


SUMMARY: Engineering Division of Planning and Development Services Department has received, Sheets 1 and 2 of the proposed Final Plat, Draft Master Declaration of Covenant for Maintenance of Common Area Improvements, and a copy of the Title Report. Engineering Division has reviewed the submitted Final Plat and Title Report and does not recommend approval of the Final Plat at this time. The following items need to be addressed:


FINAL PLAT COMMENTS:

1) DS Sec.2-03.6.1.K: Revise the Final Plat to indicate the subdivision cases number assigned (S11-014) in the lower right hand corner of the plans on all sheets.

2) DS Sec.2-03.6.2.H: Revise the Final Plat to include the following General Note: "There will be no further division of lots without the expressed approval of the City of Tucson."

3) DS Sec.2-03.6.3.B: Revise the Dedication paragraph to include the recordation # for the proposed CC&Rs.

4) DS Sec.2-03.6.3.D: Revise the Approval Paragraph to include all of the statement from the referenced section. The statement on the proposed plat should include all of the following language; "Witness my hand and official seal, the day and year above as written."

5) DS Sec.2-03.6.3.E: Revise the signature lines within the Assurance Section on Sheet 1 to include the entire name for the Planning & Development Services Department

6) DS Sec.2-03.6.4.A: Clarify on the proposed plat the existing drainage easement for the drainage infrastructure and detention/retention basin. Per the proposed the easement is to be granted by this Final Plat approval however the easement has already been dedicated by the last Final Plat for Business Park of the Desert recorded under Book 64 Page 57. Verify if there are changes in the easement that requires new recordation or revise to show the recordation number that currently exist for all easements.

7) DS Sec.2-03.6.6.A: Revise the Master Declaration of Covenant for Maintenance of Common Area Improvements to accurately reflect all of the proper common area labels and responsibility for maintenance and liability for any proposed commonly-owned areas. Revise the following information within the Master Declaration of Covenant for Maintenance of Common Area Improvements:

a) Revise to accurately describe the property (Name, number of lots and blocks, common areas, with descriptions) per the Title Block. Either the Master Declaration of Covenant for Maintenance of Common Area Improvements or the Title Block must be revised and must match with exact wording for the name and all common areas.

b) Provide all Exhibits A, B and C within the Master Declaration of Covenant for Maintenance of Common Area Improvements. All exhibits must be provided in order for the Master Declaration of Covenant for Maintenance of Common Area Improvements to be a complete package.

c) Revise all portion of the Master Declaration of Covenant for Maintenance of Common Area Improvements that references Book and Page, instead these areas should reference the Sequence #.

d) Verify that all blanks within the Master Declaration of Covenant for Maintenance of Common Area Improvements are filled in.

8) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until Financial Assurances are submitted and approved.


GENERAL COMMENTS:

Provide a revised Final Plat at re-submittal. The revised Final Plat must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Final Plat.

For questions or to schedule a meeting I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
05/25/2011 JWILLIA4 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
05/26/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

May 26, 2011

Dan Castro
Rick Engineering Co, Inc.
3945 E. Fort Lowell Rd. # 111
Tucson, Arizona 85712

Subject: S11-014 Business Park of the Desert Final Plat

Dear Dan:

Your submittal of April 26, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 5 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Final Plat (TEP, Wastewater, Zoning, Engineering, PDSD)

2 Copies Approved Site Plan (Zoning, PDSD)

3 Copies CC&R's (Zoning, Engineering, PDSD)

Should you have any questions, please call me at 837-4893.

Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 520-322-6956