Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S11-006
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/01/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/07/2011 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S11-006 The District Final Plat - (Block Plat) TRANSMITTAL DATE: April 7, 2011 DUE DATE: April 18, 2011 COMMENTS: Conditionally approved 1. Zoning conditionally approves the Final Plat as submitted. As of this review there is an understanding that the Plat will not be recorded due to ongoing negotiations with the adjacent landowners. It is further acknowledged that there will be a re-submittal of the development package depicting the new layout for the northwest area of the site which will include a parking lot and revisions to 5th Avenue street design. A revised Final Plat drawing will be required for review and approval based on the final design which may include the additional parcels under negotiations. Once the revised final plat drawing is revised and approved by Mayor and council the plat will be recorded. Per the PDSD Directors concurrence of Paul J. Iezzi's letter, permits for buildings will be issued for construction assuming that complete zoning approval of the development package is granted and any MDR issues related to an appeal or conditions are addressed. PDSD will place a hold on issuance of permits until such time as complete zoning approval is granted. Once the building permits are issued a hold on issuance of the C of O for all buildings will be placed on all buildings until such time the final plat is recorded. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\finalplat\S11-006fpca.doc |
| 04/12/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES April 12, 2011 Tri Miller Rick Engineering Company, Inc. 3945 E. Fort Lowell Rd. #111 Tucson, Arizona 85712 Subject: S11-006 THE DISTRICT Final Plat Dear Tri: Your submittal of February 3, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Final Plat (Zoning, Assessor, PDSD) 2 Copies Ownership Deed Documentation for Parcels (Assessor, PDSD) Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |
| 04/12/2011 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | Laith Alshami, Engineering and Floodplain Review, 04/12/2011, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: The District S11-006, T14S, R13E, SECTION 12 RECEIVED: Final Plat on April 04, 2011 The subject submittal has been reviewed. The Final Plat is acceptable and it is hereby recommended for approval pertaining to Engineering and Floodplain Review. |
| 04/12/2011 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Denied | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Sherry Hyde Senior Property Technician Pima County Assessor’s Office DATE: 4/11/11 RE: Assessor’s Review and Comments Regarding S11-006 THE DISTRICT: RESUBMITTAL * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * COMMENTS: THE FOLLOWING WAS NOT ADDRESSED FROM THE PRIOR LETTER DATED 3/15/11. THE DEDICATION SHOWS OWNERSHIP TO BE TUCSON HOUSING LLC, HOWEVER, THE ASSESSOR’S OFFICE SHOWS LANDMARK TITLE TR 18121 & TITLE SECURITY AGENCY OF ARIZONA TR 2004. I CANNOT LOCATE ANY DEED SHOWING OWNERSHIP OF THESE PARCELS TO BE TUCSON HOUSING LLC. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |