Plan Number: S10-024
Parcel: Unknown

Address:
6109 E PIMA ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S10-024
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/26/2010 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/02/2010 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Alamo Lofts
S10-024 (2nd Review)
Final Plat

TRANSMITTAL DATE: August 02, 2010

DUE DATE: September 13, 2010

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section conditionally approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

1. Provide the DSMR case number near the lower right hand corner, near the title block of the plan.

2. General Note 7 is not a requirement of D.S. 2-03. Remove General Note 7 from the plat.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C\planning\cdrc\finaplat\S10-024fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
09/07/2010 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)
FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor’s Office


DATE: 9/7/10


RE: Assessor’s Review and Comments Regarding
S10-024 ALAMO LOFTS: RESUBMITTAL

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS: THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER IS MISSING THE SECTION, TOWNSHIP & RANGE.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
09/09/2010 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Approved September 9, 2010

To: Dan Castro
Rick Engineering

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C Patel, P.E., Civil Eng. Manager
Development Review Division (Wastewater)

Subject: ALAMO LOFTS, Lots 1 Thru 22, Common Areas “A”, “B-1” Thru “B-6” & “C”
Final Plat – 2nd Submittal
S10--024



The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The The PDEQ and the PCRWRD hereby approve the above referenced submittal of the Final Plat received by us on August 26, 2010.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above comments, please do not hesitate to contact me.
09/14/2010 FERNE RODRIGUEZ UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: ALAMO LOFTS

S10-024



Tucson Electric Power Co. (TEP) approves the final plat submitted for
review August 26, 2010.

Electric service will be provided to this subdivision in accordance with
the rules and regulations approved by the Arizona Corporation
Commission.

Please forward any resubmittals of the final plat to this office.



Please contact me at (520) 917-8745 if you have any questions.





Liza Castillo

Right of Way Agent II

Tucson Electric Power Co.

UniSource Energy Services

offc-(520) 917-8745

fax-(520) 545-1416

lcastillo@tep.com <mailto:lcastillo@tep.com>
09/15/2010 PGEHLEN1 CC&R CC&R's Denied Denied per Engineering comments.
09/15/2010 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: September 14, 2010
CDRC/Zoning Manager
SUBJECT: Alamo Lofts, 6109 E. Pima Street
Tentative Plat, Final Plat S09-010 and Grading Plan T10BU00987 (Second Review)
T14S, R14E, Section 01

SUBMITTAL REQUIRED: Final Plat, Tentative Plat, Drainage Report and Grading Plan (Development Package).

The Final Plat (FP), Tentative Plat (SP), Drainage Report (DR) and Grading Plan (T10BU00987) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a detailed response letter to the comments along with the corrected copies of the FP.
2. Submit the remaining assurance for review:
" Amendment to Trust

3. Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review.
4. Common areas "B-1" Thru "B-6" will need to be described individually in the title block per D.S. 2-01.3.9.C.


Tentative Plat:

1. Please include a detailed response letter to the comments along with the corrected copies of the TP.
2. Common areas "B-1" Thru "B-6" will need to be described individually in the title block per D.S. 2-01.3.9.C.
3. The 10-year event must flow under all the pedestrian paths from any area. Adjust the drainage/sidewalk so that the flow is not on top of the sidewalks and show the placement and size of the sidewalk scuppers. A DSMR (DS10-15) was conditionally approved by Matt Flick. Here is the response and conditions for the DSMR:
PDSD Engineering CONDITIONALLY APPROVES the DSMR with the following condition:

Flow shall be taken beneath sidewalks at locations of concentrated flow. This is necessary to ensure conformance with Rezoning Condition #12 as per Ord. 10370: "The pedestrian circulation path, in any form, must be free from inundation during runoff from a ten-year storm."

4. Correct the "See Sheet" numbers on pages 5 and 6.


Drainage Report:
1. Please include a detailed response letter to the comments along with the corrected copies of the DR.
2. The addendum to the DR must be submitted along with the original DR provided all comments have been met.
3. An addendum to the original DR will be accepted addressing the proposed changes in the drainage scheme especially the new channel at the north property line.
4. Provide details of all drainage structures in the DR or the addendum.
5. The 10-year event must flow under all the pedestrian paths from any area. Adjust the drainage/sidewalk so that the flow is not on top of the sidewalks and show the placement and size of the sidewalk scuppers. A DSMR (DS10-15) was conditionally approved by Matt Flick. Here is the response and conditions for the DSMR:
PDSD Engineering CONDITIONALLY APPROVES the DSMR with the following condition:

Flow shall be taken beneath sidewalks at locations of concentrated flow. This is necessary to ensure conformance with Rezoning Condition #12 as per Ord. 10370: "The pedestrian circulation path, in any form, must be free from inundation during runoff from a ten-year storm."

Grading Plan:
1. Please include a detailed response letter to the comments along with the corrected copies of the GP.
2. The 10-year event must flow under all the pedestrian paths from any area. Adjust the drainage/sidewalk so that the flow is not on top of the sidewalks and show the placement and size of the sidewalk scuppers. A DSMR (DS10-15) was conditionally approved by Matt Flick. Here is the response and conditions for the DSMR:
PDSD Engineering CONDITIONALLY APPROVES the DSMR with the following condition:

Flow shall be taken beneath sidewalks at locations of concentrated flow. This is necessary to ensure conformance with Rezoning Condition #12 as per Ord. 10370: "The pedestrian circulation path, in any form, must be free from inundation during runoff from a ten-year storm."

Stormwater pollution prevention plan:
1. The SWPPP is a plan that is a dynamic entity. Therefore the previously approved SWPPP showing the major changes on the subdivision will suffice for this project.
2. The SWPPP text, NOI, NOT, general permit, certifications etc. must also be submitted along with the SWPPP plan in the DP.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/6109 E. Pima St CDRC DEV PKG 2
09/16/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

September 15, 2010

Dan Castro
Rick Engineering Company
3945 E. Fort Lowell Road # 111
Tucson, Arizona 85712

Subject: S10-024 ALAMO LOFTS Final Plat

Dear Dan:

Your submittal of June 21, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Final Plat (Zoning, Engineering, PDSD)

2 Copies Assurances "Amendment to Trust" (Engineering, PDSD)

Should you have any questions, please call me at 837-4917.


Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 322-6956
09/16/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES
*** REVISION ***
September 16, 2010


Dan Castro
Rick Engineering Company
3945 E. Fort Lowell Road # 111
Tucson, Arizona 85712

Subject: S10-024 ALAMO LOFTS Final Plat

Dear Dan:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) 8 ½" X 11" copy of plat
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page and fees for consent(s) to dedicate, if applicable.
(1) Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable). One original set and one copy of each.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Please Note: You may not submit the final plans until the DSMR decision has been completed and the required information has been added to the plats.

Should you have any questions, please call me at 837-4917.



Sincerely,




John Williams
Planning Technician



All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (520) 322-6956