Plan Number: S10-014
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S10-014
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/01/2010 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/01/2010 FERNE RODRIGUEZ COT NON-DSD REAL ESTATE Passed
04/05/2010 ED ABRIGO PIMA COUNTY ASSESSOR Approv-Cond Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Sherry Hyde
Senior Property Technician
Pima County Assessor’s Office


DATE: 4/5/10


RE: Assessor’s Review and Comments Regarding
S10-014 LOTS 4 & 5 OF ALBERTSONS AT EL RIO PLAZA


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.

COMMENTS:
THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER MUST HAVE THE NUMBER OF LOTS OR UNITS OR BLOCKS OR ANY COMBINATION OF THESE.
THE LOCATION MAP IN THE UPPER RIGHT HAND CORNER MUST HAVE THE SECTION, TOWNSHIP AND RANGE.
THE DEDICATION DOES NOT MENTION LOT 2 OF THE SUBDIVISION, WHICH THE ASSESSOR’S OFFICE SHOWS BEING OWNED BY TUCSON FEDERAL CREDIT UNION BY DOCKET 13555, PAGE 4465.


NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
04/09/2010 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: Lots 4 & 5 of Albertsons at El Rio Plaza
S10-014

Tucson Electric Power Company has reviewed and approves the final plat
submitted for review April 1, 2010 .

In order to apply for electric service, call the New Construction
Department at (520) 918-8300. Submit a final set of plans including
approved site, electrical load, paving off-site improvements and
irrigation plans, if available include a CD with the AutoCAD version of
the plans.

If easements are required, they will be secured by separate instrument.
Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Please call me at (520) 917-8745, should you have any questions.



Liza Castillo, Right of Way Agent II
Tucson Electric Power Co.
Unisource Energy Services
offc-(520) 917-8745
fax-(520) 545-1416
lcastillo@tep.com
04/09/2010 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207

AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S10-014 LOTS 4 & 5 OF ALBERTSON’S AT EL RIO PLAZA/FINAL PLAT
DATE: April 7, 2010



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

The Location Map must be 3”=1 mile. Please correct.

Include the township, range and sections under the Location Map.

Include Lots 1-4 under the name of the subdivision on all Title Blocks.

Spell out all the street suffixes except on the Location Map.

Delete all the adjacent tax codes.

Change unsubdivided 115-21-151D to Book 20, Page 72 on sheet 1.
04/13/2010 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Lots 4 & 5 of Albertson's at El Rio Plaza
S10-014
Final Plat

TRANSMITTAL DATE: April 13, 2010

DUE DATE: April 16, 2010

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is March 31, 2011

2. D.S. 2-03.6.1.D The location map should be drawn at a 3" = 1 mile scale.

3. D.S. 2-03.6.1.D.3 Section, township, and range; section corners; north arrow; and the scale will be labeled on the location map

4. D.S. 2-03.6.1.K Place the S10-014 subdivision case number assigned to the plat in the lower right hand corner of the plat next to the title block.

5. D.S. 2-03.6.1.K Provide the following reference case numbers on the plan; D09-0039, D08-0028, D00-0003, C9-68-18, C9-82-06, S98-066.

6. D.S. 2-03.6.2.D Add the following case numbers to General Note 4, C9-68-18, C9-82-06.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C\planning\cdrc\finaplat\S10-014fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
04/13/2010 JASON GREEN ENGINEERING REVIEW Denied DATE: April 13, 2010
SUBJECT: Lots 4 & 5 of Albertsons @ El Rio Plaza Final Plat Submittal- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 1720 W Speedway Blvd, T14S R13E Sec03 Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: S10-014


SUMMARY: Engineering Division of Planning and Development Services Department has received, Sheets 1 and 2 of the proposed Final Plat and a copy of the Title Report. Engineering Division has reviewed the submitted Final Plat and does not recommend approval of the Final Plat at this time. The following items need to be addressed:


FINAL PLAT COMMENTS:

1) DS Sec.2-03.6.1.D.3: Revise the project location map to label the required 3-inch equals 1-mile scale. Clearly label the Township, Range and Section corners along with the north arrow.

2) DS Sec.2-03.6.1.K: Revise the Final Plat to indicate the subdivision cases number assigned (S10-014) in the lower right hand corner of the plans on all sheets.

3) DS Sec.2-03.6.1.K: Revise the Final Plat to indicate the rezoning case number (C9-68-18) associated with the project in the lower right hand corner of the plans on all sheets.

4) DS Sec.2-03.6.2.D: Provide a General Note to state that the property is subject to conditions of rezoning, add the following note: "This plat is subject to the conditions of rezoning case number C9-68-18, unless superseded by a subsequent rezoning ordinance."

5) DS Sec.2-03.6.2.E: Provide the following note on the Final Plat; "Prior to issuance of any grading permit or building permit a Floodplain Use Permit is required for Lot 4." The lot listed has delineated floodplain and verification that no disturbance within the mapped floodplain is required at building plan submittal.

6) DS Sec.2-03.6.2.I: Provide a General Note on the Final Plat to state; "Any relocation, modification, etc., of existing utilities and/or public improvements necessitated by the proposed development will be at no expensive to the public."

7) DS Sec.2-03.6.3.E: Revise the Assurance paragraph to read per the referenced section and Department Directive; "This is to certify that all improvements, such as streets, sidewalks, private sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by the posting of performance bonds, assurances, or other security as the City of Tucson deems necessary and proper."
_____________________________________________
City of Tucson Development Services Department Director
_________________________________________________________
City of Tucson Development Services Department Engineering Administrator

8) DS Sec.2-03.6.4.F: Revise the Final Plat to label and dimension the limits of the 100-year floodprone area, Keynote #9, in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines.

9) DS Sec.2-03.6.5.C.4.a: Revise the Final Plat or Legend to provide the LS # for all new proposed subdivision corners that are labeled as "set." For all monuments found fully describe and show all markings, including the LS #.

10) DS Sec.2-03.6.5.C.4.b: Revise the Final Plat to label all monumentation in plan view at the new proposed lot corners that are labeled in the Legend as "set" with LS # 19344. Clarify the LS # used to set the corner pins to the LS # used to sign the Certificate of Survey Section.

11) DS Sec.2-03.6.5.C.5: Revise the Final Plat to clearly indicate whether the distance and bearings between monuments were measured or calculated for all property line boundary information. This can be labeled in plan view are as a note within the General Note Section or Legend.


GENERAL COMMENTS:

Provide a revised Final Plat at re-submittal. The revised Final Plat must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the Final Plat.

For questions or to schedule a meeting I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
04/19/2010 JWILLIA4 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
04/20/2010 FERNE RODRIGUEZ COT NON-DSD TUCSON AIRPORT AUTHORITY Approved TAA has reviewed the proposed final plat and has no objection.

Respectfully

Jordan D. Feld, CM, AICP
Director of Planning
Tucson Airport Authority
7005 S. Plumer Ave.
Tucson, AZ 85756
jfeld@tucsonairport.org <mailto:jfeld@tucsonairport.org>
www.tucsonairport.org <http://www.tucsonairport.org/>
(520) 573-5115 office
(520) 573-8006 fax
04/21/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

April 21, 2010

Sherri Koshiol
Vantage Resources LLC
3010 S. Priest Drive # 102
Tempe, Arizona 85282

Subject: S10-014 Lots 4 & 5 of Alberstons at El Rio Plaza Final Plat

Dear Sherri:

Your submittal of April 1, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 5 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Final Plat (Assessor, Addressing, Engineering, Zoning, PDSD)

Should you have any questions, please call me at 837-4917.


Sincerely,





John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: N/A emailed to sherri@vantageresourcesllc.com
04/21/2010 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Approved April 21, 2010

To: VANTAGE RESOURCES LLC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Tom Porter, Sr CEA
Regional Wastewater Reclamation Department

Subject: LOTS 4 & 5 OF "ALBERTSON'S AT EL RIO PLAZA"
Final Plat – 1st Submittal
S10-014



The drawings of the Final Plat for the proposed project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Regional Wastewater Reclamation Department (PCRWRD).This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The Pima County Department of Environmental Quality and Regional Wastewater Reclamation Department hereby approve the above referenced submittal of the final plat as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.