Plan Number: S10-007
Parcel: Unknown

Address:
209 W 17TH ST

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S10-007
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2010 GBONILL1 START PLANS BEING WALKED THRU Completed
03/03/2010 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: Michael St.Paul: Planning Technician


PROJECT:
S10-007
209 & 219 West 17th Street
Lot Split


TRANSMITTAL: March 3, 2010

COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment. An approved variance is required for the proposed reduced lot size.


The proposed lot in the west portion is in the HO-3 zone and east portion is HC-3. Historic review shall be required for both the proposed lots (LUC Section 2.8.8.5).

The DDO process shall be required for the proposed setbacks for each lot:

The Development Designator for the proposed east lot in the HC-3 zone is "S" (LUC Section 2.5.5.2.F.1). The Perimeter Yard Indicator is CC (LUC Sections 3.2.3.1.D & 3.2.6.4). The minimum required setback to the proposed property line equals the height of each structure's wall (LUC Section 3.2.6.4). The proposed setback is zero.

The Development Designator for the proposed west lot in the HO-3 zone is "L" (LUC Section 2.4.3.D). The Perimeter Yard Indicator is BB (LUC sections 3.2.3.1.C & 3.2.6.4). The minimum required setback to the proposed property line equals the height of each structure's wall (LUC Section 3.2.6.4). The proposed setback is zero.

The minimum lot size for residential use in the HO-3 zone is five thousand (5000) square feet (LUC Section 2.4.3.D & 3.2.3.1.C). The propose lot size for the west lot in the HO-3 zone is three thousand six hundred eighty one (3681) square feet.
04/14/2011 CPIERCE1 ZONING HC REVIEW Needs Review
04/14/2011 CPIERCE1 ZONING-RECORDATION REVIEW Completed
07/08/2010 JASON GREEN ENGINEERING REVIEW Approved
07/08/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Approved
12/17/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved